... ... @@ -2424,11 +2424,15 @@
2424 2424  (% style="text-align:center" %)
2425 2425  (((
2426 2426  (% style="display:inline-block" %)
2427 -[[Figure 9-8-2 Reverse rotation dead zone time diagram>>image:1763107356720-587.png]]
2427 +[[Caption>>image:1763107356720-587.png]]
2428 2428  )))
2429 2429  
2430 -|(% rowspan="2" style="text-align:center" %)F8.14|(% style="text-align:center" %)The carrier frequency is adjusted with temperature|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1
2431 -|(% style="text-align:center" %)Setting range|(% colspan="2" %)(((
2430 +
2431 +Figure 9-8-2 Reverse rotation dead zone time diagram
2432 +
2433 +
2434 +|(% rowspan="2" %)F8.14|The carrier frequency is adjusted with temperature|Factory default|1
2435 +|Setting range|(% colspan="2" %)(((
2432 2432  0: Temperature independent
2433 2433  
2434 2434  1:Temperature dependent, >75, 1.0Khz
... ... @@ -2436,8 +2436,8 @@
2436 2436  
2437 2437  Effective carrier frequency temperature adjustment means that the VFD can automatically adjust the carrier frequency according to its own temperature. Select this function to reduce the chances of VFD overheating alarm.
2438 2438  
2439 -|(% rowspan="2" style="text-align:center" %)F8.15|(% style="text-align:center" %)Terminal action is preferred|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1
2440 -|(% style="text-align:center" %)Setting range|(% colspan="2" %)(((
2443 +|(% rowspan="2" %)F8.15|Terminal action is preferred|Factory default|1
2444 +|Setting range|(% colspan="2" %)(((
2441 2441  0: Invalid
2442 2442  
2443 2443  1: Valid
... ... @@ -2447,37 +2447,33 @@
2447 2447  
2448 2448  1: If the running command and the point-action command exist at the same time, the point-action command takes precedence.
2449 2449  
2450 -|(% rowspan="2" style="text-align:center" %)F8.16|(% style="text-align:center" %)Set the cumulative power-on arrival time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0h
2451 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0h to 65000h
2454 +|(% rowspan="2" %)F8.16|Set the cumulative power-on arrival time|Factory default|0h
2455 +|Setting range|(% colspan="2" %)0h to 65000h
2452 2452  
2453 2453  Pre-set the power-on time of the inverter. When the cumulative power-on time (F7.13) reaches the set power-on time, set the DO output function, and the inverter multi-function digital DO output running time arrival signal.
2454 2454  
2455 -|(% rowspan="2" style="text-align:center" %)F8.17|(% style="text-align:center" %)Set the cumulative run arrival time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)65000h
2456 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0h to 65000h
2459 +|(% rowspan="2" %)F8.17|Set the cumulative run arrival time|Factory default|65000h
2460 +|Setting range|(% colspan="2" %)0h to 65000h
2457 2457  
2458 2458  Pre-set the running time of the inverter. When the accumulated running time (F7.09) reaches this set running time, set the DO output function, the inverter multi-functional digital DO output running time arrival signal.
2459 2459  
2460 -|(% rowspan="2" style="text-align:center" %)F8.20|(% style="text-align:center" %)Arrival time of this run|(% style="text-align:center" %)Factory default|0
2461 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65000min
2464 +|(% rowspan="2" %)F8.20|Arrival time of this run|Factory default|0
2465 +|Setting range|(% colspan="2" %)0 to 65000min
2462 2462  
2463 2463  Set the current running time, shutdown clear zero.
2464 2464  
2465 -|(% rowspan="2" style="text-align:center" %)F8.22|(% style="text-align:center" %)Frequency detection value (FDT1)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)50.00Hz
2466 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00Hz to Maximum frequency
2467 -|(% rowspan="2" style="text-align:center" %)F8.23|(% style="text-align:center" %)Frequency Detection Lag value (FDT1)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)5.0%
2468 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 100.0%(FDT1 Electric level)
2469 -|(% rowspan="2" style="text-align:center" %)F8.24|(% style="text-align:center" %)Frequency detection value (FDT2)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)50.00Hz
2470 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00Hz to Maximum frequency
2471 -|(% rowspan="2" style="text-align:center" %)F8.25|(% style="text-align:center" %)Frequency detection lag value (FDT2)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)5.0%
2472 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 100.0%(FDT2 Electric level)
2469 +|(% rowspan="2" %)F8.22|Frequency detection value (FDT1)|Factory default|50.00Hz
2470 +|Setting range|(% colspan="2" %)0.00Hz to Maximum frequency
2471 +|(% rowspan="2" %)F8.23|Frequency Detection Lag value (FDT1)|Factory default|5.0%
2472 +|Setting range|(% colspan="2" %)0.0% to 100.0%(FDT1 Electric level)
2473 +|(% rowspan="2" %)F8.24|Frequency detection value (FDT2)|Factory default|50.00Hz
2474 +|Setting range|(% colspan="2" %)0.00Hz to Maximum frequency
2475 +|(% rowspan="2" %)F8.25|Frequency detection lag value (FDT2)|Factory default|5.0%
2476 +|Setting range|(% colspan="2" %)0.0% to 100.0%(FDT2 Electric level)
2473 2473  
2474 2474  Set the detection value of the output frequency and the lag value of the output action release.
2475 2475  
2476 -(% style="text-align:center" %)
2477 -(((
2478 -(% style="display:inline-block" %)
2479 -[[Caption>>image:1763107356721-853.png]]
2480 -)))
2480 +[[image:1763107356721-853.png]]
2481 2481  
2482 2482  Figure 9-8-3 Schematic diagram of FDT1 level
2483 2483