Changes for page 09 Function code
Last modified by Iris on 2025/11/17 14:59
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3338,7 +3338,7 @@ 3338 3338 |(% rowspan="2" style="text-align:center" %)FD.49|(% style="text-align:center" %)PLC phase 15 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3339 3339 |(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 3 3340 3340 |(% rowspan="2" style="text-align:center" %)FD.50|(% style="text-align:center" %)PLC operating time unit|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3341 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align: left" %)(((3341 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)((( 3342 3342 LED units: Timing unit 3343 3343 3344 3344 0: s(seconds) ... ... @@ -3351,11 +3351,11 @@ 3351 3351 |(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 3352 3352 0: Function code FD.00 given 3353 3353 3354 -1: AI1 given3354 +1: AI1 3355 3355 3356 -2: AI2 given3356 +2: AI2 3357 3357 3358 -3: AI3 given3358 +3: AI3 3359 3359 3360 3360 4: Set the terminal PULSE 3361 3361 ... ... @@ -3363,15 +3363,18 @@ 3363 3363 3364 3364 6: Preset frequency (F0.08) given, UP/DOWN can be modified 3365 3365 3366 -7: Keyboard potentiometer set3366 +7: keyboard potentiometer set 3367 3367 ))) 3368 3368 3369 + 3370 + 3369 3369 This parameter determines the target amount of the multi-segment speed 0 given channel. 3370 3370 3371 3371 FD.50: PLC operating time unit. 3372 3372 3373 -|(% rowspan="2" style="text-align:center" %)FD.52|(% style="text-align:center" %)Multiple speed is preferred|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1 3374 -|(% style="text-align:center" %)Set range|(% colspan="2" style="text-align:center" %)((( 3375 + 3376 +|(% rowspan="2" %)FD.52|Multiple speed is preferred|Factory default|1 3377 +|Set range|(% colspan="2" %)((( 3375 3375 0: Invalid 3376 3376 3377 3377 1: Valid ... ... @@ -3379,20 +3379,21 @@ 3379 3379 3380 3380 Set this parameter to 1, F0.03 set the main frequency source not to multi-segment speed, and set F5 group terminal parameter multi-segment speed function~,~, when the terminal is valid, the frequency source switches to the multi-segment speed set, the multi-segment speed priority has nothing to do with the multi-segment speed 0. 3381 3381 3382 - ==**FE Group user password**==3385 +**FE Group user password** 3383 3383 3384 -|(% rowspan="2" style="text-align:center"%)FE.00|(% style="text-align:center" %)User password|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)03385 -| (% style="text-align:center" %)Setting range|(% colspan="2"style="text-align:center"%)0 to 655353387 +|(% rowspan="2" %)FE.00|User password|Factory default|0 3388 +|Setting range|(% colspan="2" %)0 to 65535 3386 3386 3387 3387 If the value is set to any non-zero number, the password protection function takes effect. 00000: Clears the previously set password value and invalidates the password protection function. After the user password is set and takes effect, if you enter the parameter setting state again and the user password is incorrect, the parameter group cannot be entered and cannot be viewed/modified. Remember the user password you set. If you accidentally set or forget, please contact the manufacturer. 3388 3388 3389 -|(% rowspan="2" style="text-align:center"%)FE.01|(% style="text-align:center" %)Number of times to display fault records|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)43390 -| (% style="text-align:center" %)Setting range|(% colspan="2"style="text-align:center"%)0 to 83392 +|(% rowspan="2" %)FE.01|Number of times to display fault records|Factory default|4 3393 +|Setting range|(% colspan="2" %)0 to 8 3391 3391 3392 3392 This function code is used to set the number of times that fault records are displayed. 3393 3393 3394 -|(% rowspan="2" style="text-align:center" %)FE.02|(% style="text-align:center" %)Parameter and key lock selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3395 -|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 3397 + 3398 +|(% rowspan="2" %)FE.02|Parameter and key lock selection|Factory default|0 3399 +|Setting range|(% colspan="2" %)((( 3396 3396 0: Not locked 3397 3397 3398 3398 1: The function parameter is locked ... ... @@ -3400,10 +3400,11 @@ 3400 3400 3401 3401 This function code is used to lock a parameter. After the parameter is locked, it cannot be modified. 3402 3402 3403 -== **A0 Displays the parameter group** == 3404 3404 3405 -|(% rowspan="2" style="text-align:center" %)A0.00|(% style="text-align:center" %)Application macro|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3406 -|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 3408 +**A0 Displays the parameter group** 3409 + 3410 +|(% rowspan="2" %)A0.00|Application macro|Factory default|0 3411 +|Setting range|(% colspan="2" %)((( 3407 3407 0: Default macro 3408 3408 3409 3409 1: Tile press macro