... ... @@ -3338,7 +3338,7 @@
3338 3338  |(% rowspan="2" style="text-align:center" %)FD.49|(% style="text-align:center" %)PLC phase 15 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0
3339 3339  |(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 3
3340 3340  |(% rowspan="2" style="text-align:center" %)FD.50|(% style="text-align:center" %)PLC operating time unit|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0
3341 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:left" %)(((
3341 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)(((
3342 3342  LED units: Timing unit
3343 3343  
3344 3344  0: s(seconds)
... ... @@ -3351,11 +3351,11 @@
3351 3351  |(% style="text-align:center" %)Setting range|(% colspan="2" %)(((
3352 3352  0: Function code FD.00 given
3353 3353  
3354 -1: AI1 given
3354 +1: AI1
3355 3355  
3356 -2: AI2 given
3356 +2: AI2
3357 3357  
3358 -3: AI3 given
3358 +3: AI3
3359 3359  
3360 3360  4: Set the terminal PULSE
3361 3361  
... ... @@ -3363,15 +3363,18 @@
3363 3363  
3364 3364  6: Preset frequency (F0.08) given, UP/DOWN can be modified
3365 3365  
3366 -7: Keyboard potentiometer set
3366 +7: keyboard potentiometer set
3367 3367  )))
3368 3368  
3369 +
3370 +
3369 3369  This parameter determines the target amount of the multi-segment speed 0 given channel.
3370 3370  
3371 3371  FD.50: PLC operating time unit.
3372 3372  
3373 -|(% rowspan="2" style="text-align:center" %)FD.52|(% style="text-align:center" %)Multiple speed is preferred|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1
3374 -|(% style="text-align:center" %)Set range|(% colspan="2" style="text-align:center" %)(((
3375 +
3376 +|(% rowspan="2" %)FD.52|Multiple speed is preferred|Factory default|1
3377 +|Set range|(% colspan="2" %)(((
3375 3375  0: Invalid
3376 3376  
3377 3377  1: Valid
... ... @@ -3379,20 +3379,21 @@
3379 3379  
3380 3380  Set this parameter to 1, F0.03 set the main frequency source not to multi-segment speed, and set F5 group terminal parameter multi-segment speed function~,~, when the terminal is valid, the frequency source switches to the multi-segment speed set, the multi-segment speed priority has nothing to do with the multi-segment speed 0.
3381 3381  
3382 -== **FE Group user password** ==
3385 +**FE Group user password**
3383 3383  
3384 -|(% rowspan="2" style="text-align:center" %)FE.00|(% style="text-align:center" %)User password|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0
3385 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535
3387 +|(% rowspan="2" %)FE.00|User password|Factory default|0
3388 +|Setting range|(% colspan="2" %)0 to 65535
3386 3386  
3387 3387  If the value is set to any non-zero number, the password protection function takes effect. 00000: Clears the previously set password value and invalidates the password protection function. After the user password is set and takes effect, if you enter the parameter setting state again and the user password is incorrect, the parameter group cannot be entered and cannot be viewed/modified. Remember the user password you set. If you accidentally set or forget, please contact the manufacturer.
3388 3388  
3389 -|(% rowspan="2" style="text-align:center" %)FE.01|(% style="text-align:center" %)Number of times to display fault records|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)4
3390 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 8
3392 +|(% rowspan="2" %)FE.01|Number of times to display fault records|Factory default|4
3393 +|Setting range|(% colspan="2" %)0 to 8
3391 3391  
3392 3392  This function code is used to set the number of times that fault records are displayed.
3393 3393  
3394 -|(% rowspan="2" style="text-align:center" %)FE.02|(% style="text-align:center" %)Parameter and key lock selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0
3395 -|(% style="text-align:center" %)Setting range|(% colspan="2" %)(((
3397 +
3398 +|(% rowspan="2" %)FE.02|Parameter and key lock selection|Factory default|0
3399 +|Setting range|(% colspan="2" %)(((
3396 3396  0: Not locked
3397 3397  
3398 3398  1: The function parameter is locked
... ... @@ -3400,10 +3400,11 @@
3400 3400  
3401 3401  This function code is used to lock a parameter. After the parameter is locked, it cannot be modified.
3402 3402  
3403 -== **A0 Displays the parameter group** ==
3404 3404  
3405 -|(% rowspan="2" style="text-align:center" %)A0.00|(% style="text-align:center" %)Application macro|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0
3406 -|(% style="text-align:center" %)Setting range|(% colspan="2" %)(((
3408 +**A0 Displays the parameter group**
3409 +
3410 +|(% rowspan="2" %)A0.00|Application macro|Factory default|0
3411 +|Setting range|(% colspan="2" %)(((
3407 3407  0: Default macro
3408 3408  
3409 3409  1: Tile press macro