... ... @@ -430,7 +430,7 @@
430 430  
431 431  This parameter is not restored when restoring factory defaults.
432 432  
433 -|(% rowspan="2" style="text-align:center" %)F0.27|(% style="text-align:center" %)Modulation ratio coefficient|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)100.0%
433 +|(% rowspan="2" style="text-align:center" %)F0.27|(% style="text-align:center" %)Modulation ratio coefficient|(% style="text-align:center" %)Factory default|100.0%
434 434  |(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)10.0 to 150.0%
435 435  
436 436  This parameter is the upper limit of the modulation ratio. The lower the modulation ratio, the lower the maximum output voltage; The higher the modulation ratio, the more obvious the current distortion during over modulation.
... ... @@ -437,8 +437,8 @@
437 437  
438 438  == **F1 group start stop control** ==
439 439  
440 -|(% rowspan="2" style="text-align:center" %)F1.00|(% style="text-align:center" %)Start-up operation mode|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)00
441 -|(% style="text-align:center" %)Setting range|(% colspan="2" %)(((
440 +|(% rowspan="2" %)F1.00|Start-up operation mode|Factory default|00
441 +|Setting range|(% colspan="2" %)(((
442 442  LED ones place: Boot mode
443 443  
444 444  0: Start directly from the start frequency
... ... @@ -458,8 +458,9 @@
458 458  
459 459  Pre-excitation current, time and DC braking current, time share function code. If F1.09 pre-start braking time is set to 0, start from the start frequency. When the value is not set to 0, pre-excitation is implemented before startup to improve the dynamic response speed.
460 460  
461 -|(% rowspan="2" style="text-align:center" %)F1.01|(% style="text-align:center" %)Speed tracking mode|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0
462 -|(% style="text-align:center" %)Setting range|(% colspan="2" %)(((
461 +
462 +|(% rowspan="2" %)F1.01|Speed tracking mode|Factory default|0
463 +|Setting range|(% colspan="2" %)(((
463 463  LED tens place: speed tracking direction
464 464  
465 465  0: One to the stop direction
... ... @@ -469,54 +469,72 @@
469 469  2: Automatic search
470 470  )))
471 471  
473 +
474 +
472 472  Ten: speed tracking direction
473 473  
474 474  This parameter determines the direction from which to start speed tracking. Please set it correctly according to the actual situation. If the setting is wrong, the startup may fail. In the case of not knowing the starting direction, you can set to automatic search, the program will automatically judge the starting direction, but the search time will be lengthened accordingly.
475 475  
476 -|(% rowspan="2" style="text-align:center" %)F1.02|(% style="text-align:center" %)Speed tracking time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1.00s
477 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.01 to 60.00s
478 478  
480 +|(% rowspan="2" %)F1.02|Speed tracking time|Factory default|1.00s
481 +|Setting range|(% colspan="2" %)0.01 to 60.00s
482 +
483 +
484 +
479 479  If the speed tracking time is too short, the tracking may end without tracking the actual frequency. At F1.01=002X, if the search direction is wrong, two searches will be performed and the actual search time will be doubled.
480 480  
481 -|(% rowspan="2" style="text-align:center" %)F1.03|(% style="text-align:center" %)Speed tracking current loop gain|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)10.00
482 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 10.00
483 -|(% rowspan="2" style="text-align:center" %)F1.04|(% style="text-align:center" %)(((
487 +
488 +|(% rowspan="2" %)F1.03|Speed tracking current loop gain|Factory default|10.00
489 +|Setting range|(% colspan="2" %)0.00 to 10.00
490 +|(% rowspan="2" %)F1.04|(((
484 484  RPM tracking
485 485  
486 486  speed gain
487 -)))|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)2.00
488 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.01 to 10.00
494 +)))|Factory default|2.00
495 +|Setting range|(% colspan="2" %)0.01 to 10.00
489 489  
497 +
498 +
490 490  The excitation search current loop gain and velocity loop gain are determined.
491 491  
492 -|(% rowspan="2" style="text-align:center" %)F1.05|(% style="text-align:center" %)Speed tracking current|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)150%
493 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)50% to 200%
494 494  
502 +|(% rowspan="2" %)F1.05|Speed tracking current|Factory default|150%
503 +|Setting range|(% colspan="2" %)50% to 200%
504 +
505 +
506 +
495 495  Set the excitation search current size.
496 496  
497 -|(% rowspan="2" style="text-align:center" %)F1.06|(% style="text-align:center" %)Starting frequency|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.00Hz
498 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s to 60.00Hz
499 -|(% rowspan="2" style="text-align:center" %)F1.07|(% style="text-align:center" %)Startup frequency duration|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s
500 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 to 50.0s
509 +|(% rowspan="2" %)F1.06|Starting frequency|Factory default|0.00Hz
510 +|Setting range|(% colspan="2" %)0.0s to 60.00Hz
511 +|(% rowspan="2" %)F1.07|Startup frequency duration|Factory default|0.0s
512 +|Setting range|(% colspan="2" %)0.0 to 50.0s
501 501  
502 -In order to ensure the torque during startup, please use the appropriate startup frequency. In addition, the magnetic flux is established when waiting for the motor to start, so that the starting frequency is maintained for a certain time before accelerating. The starting frequency is maintained for a certain time before accelerating. The startup frequency F1.06 is not limited by the lower frequency. If the frequency given less than startup frequency, the AC driver can no be started, and it will standby state. The startup frequency holding time is not work during forward/reverse switching. The holding time is not included in the acceleration time, but is included in the running time of the simple PLC.
503 503  
504 -|(% rowspan="2" style="text-align:center" %)F1.08|(% style="text-align:center" %)Braking current before starting|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)80.0%
505 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 to 150.0%
506 -|(% rowspan="2" style="text-align:center" %)F1.09|(% style="text-align:center" %)Braking time before starting|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s
507 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 to 60.0s
508 508  
516 +In order to ensure the torque during startup, please use the appropriate startup frequency.In addition, the magnetic flux is established when waiting for the motor to start, so that the starting frequency is maintained for a certain time before accelerating.The starting frequency is maintained for a certain time before accelerating. The startup frequency F1.06 is not limited by the lower frequency. If the frequency given less than startup frequency, the AC driver can no be started, and it will standby state.The startup frequency holding time is not work during forward/reverse switching. The holding time is not included in the acceleration time, but is included in the running time of the simple PLC.
517 +
518 +|(% rowspan="2" %)F1.08|Braking current before starting|Factory default|80.0%
519 +|Setting range|(% colspan="2" %)0.0 to 150.0%
520 +|(% rowspan="2" %)F1.09|Braking time before starting|Factory default|0.0s
521 +|Setting range|(% colspan="2" %)0.0 to 60.0s
522 +
523 +
524 +
509 509  Starting DC braking is generally used to stop the motor completely before starting.
510 510  
511 511  If the starting mode is starting after the DC braking, the AC driver will execute the DC braking as the setting value, and it will start running after the setting starting braking time value. It will direct start without DC braking if the setting DC braking time is 0. The braking power is greater with the greater DC braking current.
512 512  
513 -|(% rowspan="2" style="text-align:center" %)F1.10|(% style="text-align:center" %)Shutdown mode|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0
514 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:left" %)(((
529 +
530 +|(% rowspan="2" %)F1.10|Shutdown mode|Factory default|0
531 +|Setting range|(% colspan="2" %)(((
515 515  0: Slow down stop
516 516  
517 517  1: Free stop
518 518  )))
519 519  
537 +
538 +
520 520  0: Slow down stop
521 521  
522 522  After the stop command is effective, the inverter reduces the output frequency according to the deceleration mode and the defined acceleration and deceleration time, and stops after the frequency drops to 0.
... ... @@ -525,14 +525,14 @@
525 525  
526 526  When the stop command is valid, the inverter terminates output immediately. The load stops freely according to mechanical inertia.
527 527  
528 -|(% rowspan="2" style="text-align:center" %)F1.11|(% style="text-align:center" %)Stop DC braking start frequency|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.00Hz
529 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00Hz to Maximum frequency F0.10
530 -|(% rowspan="2" style="text-align:center" %)F1.12|(% style="text-align:center" %)Stop DC braking wait time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s
531 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s to 100.0s
532 -|(% rowspan="2" style="text-align:center" %)F1.13|(% style="text-align:center" %)Stop DC braking current|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)80.0%
533 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0% to 150%
534 -|(% rowspan="2" style="text-align:center" %)F1.14|(% style="text-align:center" %)Stop DC braking duration|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s
535 -|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s to 100.0s
547 +|(% rowspan="2" %)F1.11|Stop DC braking start frequency|Factory default|0.00Hz
548 +|Setting range|(% colspan="2" %)0.00Hz to Maximum frequency F0.10
549 +|(% rowspan="2" %)F1.12|Stop DC braking wait time|Factory default|0.0s
550 +|Setting range|(% colspan="2" %)0.0s to 100.0s
551 +|(% rowspan="2" %)F1.13|Stop DC braking current|Factory default|80.0%
552 +|Setting range|(% colspan="2" %)0%-150%
553 +|(% rowspan="2" %)F1.14|Stop DC braking duration|Factory default|0.0s
554 +|Setting range|(% colspan="2" %)0.0s to 100.0s
536 536  
537 537  
538 538  
... ... @@ -542,9 +542,9 @@
542 542  
543 543  Stop DC braking current: refers to the amount of DC braking applied. The greater the value, the stronger the DC braking effect.
544 544  
545 -DC braking time: the time added to the DC braking amount. When this value is 0, it means that there is no DC braking process, and the inverter stops according to the set deceleration stop process.
564 +Dc braking time: the time added to the DC braking amount. When this value is 0, it means that there is no DC braking process, and the inverter stops according to the set deceleration stop process.
546 546  
547 -[[image:1763022599082-487.png]]
566 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml13344\wps11.jpg]]
548 548  
549 549  Figure 9-1-1 Shutdown DC braking diagram
550 550  
1763023714773-291.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -106.5 KB
Content