- Introduction
LX6V-4PT (4-channal analog inputs), used for the acquisition of thermocouple input analog signals. Suitable for Wecon LX6 series PLC and LX6V-EM□-ECAT coupler.
LX6V-EM□-ECAT firmware version that supports this module: V2.022 and above, the corresponding XML version: 1.3 and above.
Upper computer software version that supports this module: 2.6. 236 and above, PLC firmware version:2.321. 1032 and above.
✎Note: The total power of expansion modules connected to LX6 series PLC and LX6V-EM□-ECAT cannot be greater than 48W.
- Appearance and terminal description
- Appearance and size

① LED; ② Terminal; ③ Expansion module interface; ④ Mounting hole: 2 places (Φ4.5);
⑤ DIN rail buckle.
- Terminal description
The 4PT expansion module terminal are arranged as follows:
| Module model | Terminal arrangement | |
| LX6V-4PT | ![]() | |
- Installation
Please install the end cover on the right side of the last expansion module, align it with the module interface slot and connect it, as shown in the figure below:

- Indicator
The 4PT expansion module LED is shown below:
| Indicator | Description |
| PWR | Power indicator
|
| LINK | Communication indicator
|
| L1+/L2+/L3+/L4 + | Channel indicator
|
| L1-/L2-/L3-/L4- | N/A |
| I1+/I2+/I3+/I4 + | N/A |
- Parameter Specification
- Input Specification
| Item | Description |
| Input channel | 4 |
| Digital resolution | 16 bit |
| Sensitivity | 0.01℃, 0.01℉ |
| Input terminal | Thermocouple input |
| Sensor type | PT100, PT1000, CU50 |
| Accuracy (normal temperature 25℃) | Full range ± 0.2% |
| Accuracy (working temperature -20℃ to 55℃) | Full range ± 0. 3% |
| Isolation or not | I/O terminals are isolated from power supply, channels are not isolated |
| Overlimit disconnection detection | Support |
| Power consumption | < 1.1W |
| Power supply | Power supply via interface, DC24V±10%, 40mA |
- Environmental specification
Software Specifications
| Item | Specification | ||||
| Usage environment | No corrosive, combustible gas, no large amount of conductive dust | ||||
| Environment temperature | Working temperature: 0℃ to 55℃ Storage temperature: -20℃ to 70℃ | ||||
| Environment humidity | Working humidity: 10% to 90%RH (no condensation) Storage humidity: ≤ 90% RH (no condensation) | ||||
| Installation | Snap mount on DIN46277 (width 35mm) rail or direct positioning hole mount | ||||
| Vibration resistance | According to JISC0040 standard | ||||
| Installation | Frequency | Acceleration | Amplitude | X, Y, Z 10 times in each of three directions (80 minutes in each direction) | |
| DIN rail installation | 10 to 57Hz | -- | 0.035mm | ||
| 57 to 150Hz | 4.9m/S2 | -- | |||
| Direct installation | 10 to 57Hz | -- | 0.075mm | ||
| 57 to 150Hz | 9.8m/S2 | -- | |||
| Shock resistance | Compliant with JISC0041 standard (147 m/S2, action time 11ms, three sinusoidal half-wave pulses in each of X, Y, and Z directions) | ||||
| EMC immunity level | Zone B (per IEC 61131-2) | ||||
| Altitude requirements | ≤2000m (80 kPa) | ||||
| Protection level | IP20 | ||||
| Grounding | Not co-located with the strong current system | ||||
| Item | Specification |
| Input PDO data volume | Maximum 24 byte |
| Diagnostic reporting function configuration | Support |
| Diagnostic detection enable configuration | Support overlimit and disconnection detection |
| Sensor type configuration | Support thermal resistor type: PT100, PT1000, CU50, default is PT100 thermal resistance |
| Filter time | 0s to 100s (can be configured by software, default 5s) |
| Overflow detection | Support |
| Overlimit detection enable configuration | Support |
| Independent channel configuration | Support |
| Temperature offset enable configuration | Support |
| Temperature offset configuration range | -300 to +300, temperature unit |
| Display mode | Celsius (℃), Fahrenheit (℉) |
| Display sensitivity | 0.01℃, 0.01℉ |
| Sample refresh | Refresh asynchronously according to the sampling time, do not require synchronization refresh according to the bus cycle |
| Stop mode | Output according to the maximum value, no more refresh |
| Disconnected or overlimit | Output according to the maximum value, no more refresh |
| System diagnostics | System power abnormality |
| Channel diagnosis | Over upper limit alarm, over lower limit alarm, disconnection alarm, overflow alarm |
| Configuration diagnostics | Configuration error identification, channel parameter configuration error |
- Accuracy calculation
Within the working temperature range, when the temperature change rate is less than 0.3°C/min, the accuracy of this product = ADC sampling accuracy + line resistance error + contact impedance error. According to the measure principle, it is necessary to wait for the module to be powered on for 45 minutes before measuring.
| Sensor type | Detection range | Accuracy |
| PT100 | -200.0℃ to +850.0℃, -328.0℉ to +1562.0℉ | T < 300°C: ±0.6℃ 300℃ ≤ T ≤ 700℃: ±1.4℃ T > 700°C: ±1.7℃ |
| PT1000 | -200.0℃ to +850.0℃, -328.0℉ to +1562.0℉ | T < 300°C: ±0.6℃ 300℃ ≤ T ≤ 700℃: ±1.4℃ T > 700 °C: ±1.7℃ |
| CU50 | -50.0℃ to + 150.0℃, -58.0℉ to +302.0℉ | -50℃ ≤ T ≤ 150℃: ±0.3℃ |