Changes for page LX3V-2WT

Last modified by Mora Zhou on 2023/11/22 10:57

From version 6.3
edited by Stone Wu
on 2022/07/05 16:23
Change comment: There is no comment for this version
To version 6.5
edited by Stone Wu
on 2022/07/05 16:29
Change comment: (Autosaved)

Summary

Details

Page properties
Content
... ... @@ -83,10 +83,10 @@
83 83  |(% rowspan="2" style="width:121px" %)WE light|(% rowspan="2" style="width:346px" %)Calibration indicator for the channel|(% style="width:126px" %)Lights off|(% style="width:483px" %)Calibration succeeded
84 84  |(% style="width:126px" %)Always ON|(% style="width:483px" %)Calibration failed or not calibrated
85 85  
86 -== Use of blade terminals ==
86 +== **Use of blade terminals** ==
87 87  
88 88  (% style="text-align:center" %)
89 -[[image:image-20220622145005-4.jpeg||height="220" width="366"]]
89 +[[image:image-20220705162505-2.jpeg||height="218" width="375"]]
90 90  
91 91  Use crimp terminals of the size shown in the figure. Terminal tightening torque is 0.5 to 0.8N.m. Be sure to tighten the screws so as not to cause malfunction.
92 92  
... ... @@ -115,7 +115,7 @@
115 115  = **4 Wiring ** =
116 116  
117 117  (% style="text-align:center" %)
118 -[[image:image-20220622145005-5.jpeg||height="522" width="706"]]
118 +[[image:image-20220705162452-1.jpeg]]
119 119  
120 120  **✎Note:**
121 121  
... ... @@ -534,7 +534,7 @@
534 534  
535 535  |**Settings**|(% style="width:599px" %)**Description**|(% style="width:404px" %)**Remark**
536 536  |0|(% style="width:599px" %)Do not enable zero tracking|(% style="width:404px" %)Default
537 -|1 to 100|(% style="width:599px" %)When setting the zero tracking range (absolute value), tracking must be performed when the value is stable and the current weight is within the zero tracking range.|(% style="width:404px" %)(((
537 +|1 to 300|(% style="width:599px" %)When setting the zero tracking range (absolute value), tracking must be performed when the value is stable and the current weight is within the zero tracking range.|(% style="width:404px" %)(((
538 538  If set to 10, the current weight is ±9 and the stable flag is 1, the current weight is cleared.
539 539  )))
540 540  |(% colspan="3" %)**✎Note: **When the accuracy of the measured items is not high, the temperature drift has little effect, and this function is not required.
... ... @@ -618,12 +618,12 @@
618 618  The adjustment is to make the module match the weight value of the load cell of the weighing module. The adjustment steps are as follows. Described with CH1.
619 619  
620 620  (% style="text-align:center" %)
621 -[[image:image-20220622145005-8.jpeg||height="193" width="797"]]
621 +[[image:image-20220705162540-3.jpeg]]
622 622  
623 623  **Tare weight and gross weight**
624 624  
625 625  (% style="text-align:center" %)
626 -[[image:image-20220622145005-9.jpeg||height="274" width="749"]]
626 +[[image:image-20220705162551-4.jpeg]]
627 627  
628 628  **Filter mode setting**
629 629  
... ... @@ -630,7 +630,7 @@
630 630  After setting the filtering mode and filtering strength, you need to calibrate it again.
631 631  
632 632  (% style="text-align:center" %)
633 -[[image:image-20220622145005-10.jpeg||height="196" width="791"]]
633 +[[image:image-20220705162602-5.jpeg]]
634 634  
635 635  **Zero tracking**
636 636  
... ... @@ -639,7 +639,7 @@
639 639  Set Zero Tracking Intensity to 0 to disable tracking. Set Zero Tracking Range to 0 to make it is unlimited.
640 640  
641 641  (% style="text-align:center" %)
642 -[[image:image-20220622145005-11.jpeg||height="242" width="601"]]
642 +[[image:image-20220705162610-6.jpeg]]
643 643  
644 644  **Calibration without weights**
645 645  
... ... @@ -648,12 +648,12 @@
648 648  Example: The sensitivity of LAB-B-B sensor is 2.0±10%mV/V, and there may be a maximum error of 10%, so it is best to use a sensor with a small sensor sensitivity error to use this function.
649 649  
650 650  (% style="text-align:center" %)
651 -[[image:image-20220622145005-12.jpeg||height="323" width="774"]]
651 +[[image:image-20220705162619-7.jpeg]]
652 652  
653 653  **Modify calibration parameters**
654 654  
655 655  (% style="text-align:center" %)
656 -[[image:image-20220622145005-13.jpeg||height="315" width="838"]]
656 +[[image:image-20220705162627-8.jpeg]]
657 657  
658 658  **✎Note: **BFM35, BFM36, BFM37, and BFM38 are real number (float). Real numbers need to be input when inputting. If the input exceeds the range, BFM5 will report an error in writing calibration parameters.
659 659  
image-20220705162452-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +193.9 KB
Content
image-20220705162505-2.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +44.3 KB
Content
image-20220705162540-3.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +118.9 KB
Content
image-20220705162551-4.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +123.2 KB
Content
image-20220705162602-5.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +62.9 KB
Content
image-20220705162610-6.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +67.0 KB
Content
image-20220705162619-7.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +209.0 KB
Content
image-20220705162627-8.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +183.1 KB
Content