... ... @@ -85,7 +85,8 @@
85 85  
86 86  == Use of blade terminals ==
87 87  
88 -[[image:image-20220705162505-2.jpeg]]
88 +(% style="text-align:center" %)
89 +[[image:image-20220622145005-4.jpeg||height="220" width="366"]]
89 89  
90 90  Use crimp terminals of the size shown in the figure. Terminal tightening torque is 0.5 to 0.8N.m. Be sure to tighten the screws so as not to cause malfunction.
91 91  
... ... @@ -114,7 +114,7 @@
114 114  = **4 Wiring ** =
115 115  
116 116  (% style="text-align:center" %)
117 -[[image:image-20220705162452-1.jpeg]]
118 +[[image:image-20220622145005-5.jpeg||height="522" width="706"]]
118 118  
119 119  **✎Note:**
120 120  
... ... @@ -502,18 +502,18 @@
502 502  
503 503  * Calibration with weights
504 504  ** Step1: Do not put any weights on the load cell.
505 -** Step2: Write 0x0001 to #8.
506 +** Step2: #8 value is written as 0x0001.
506 506  ** Step3: Add standard weights to the load cell.
507 507  ** Step4: Write the weight of the current weight on the chassis into #23.
508 -** Step5: Write 0x0002 to #8.
509 +** Step5: #8 value is written as 0x0002.
509 509  * Weightless calibration
510 510  ** Step1: Do not put any weights on the load cell.
511 511  ** Step2: Write the maximum range of the sensor into #23.
512 512  ** Step3: Write the sensor sensitivity into #39, accurate to three decimal places.
513 -** Step4: Write 0x0003 to #8.
514 +** Step4: #8 value is written as 0x0003.
514 514  * Modify calibration parameters:
515 515  ** Step1: Modify the calibration parameter values in BFM#35 to BFM#38;
516 -** Step2: Write 0x0004 to #8.
517 +** Step2: #8 value is written as 0x0004.
517 517  
518 518  **✎Note: **When a value is written to BFM#8 or BFM#48 using the device monitor, it is automatically reset to 0.
519 519  
... ... @@ -533,7 +533,7 @@
533 533  
534 534  |**Settings**|(% style="width:599px" %)**Description**|(% style="width:404px" %)**Remark**
535 535  |0|(% style="width:599px" %)Do not enable zero tracking|(% style="width:404px" %)Default
536 -|1 to 300|(% style="width:599px" %)When setting the zero tracking range (absolute value), tracking must be performed when the value is stable and the current weight is within the zero tracking range.|(% style="width:404px" %)(((
537 +|1 to 100|(% style="width:599px" %)When setting the zero tracking range (absolute value), tracking must be performed when the value is stable and the current weight is within the zero tracking range.|(% style="width:404px" %)(((
537 537  If set to 10, the current weight is ±9 and the stable flag is 1, the current weight is cleared.
538 538  )))
539 539  |(% colspan="3" %)**✎Note: **When the accuracy of the measured items is not high, the temperature drift has little effect, and this function is not required.