Changes for page LX5V-2PT2DAI

Last modified by WeconTurkey on 2024/10/16 22:58

From version 2.1
edited by Jim
on 2022/12/22 11:07
Change comment: There is no comment for this version
To version 1.1
edited by Jim
on 2022/12/22 11:01
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -13,7 +13,6 @@
13 13  
14 14  [[image:image-20221222110100-1.png]]
15 15  
16 -(% class="table-bordered" %)
17 17  |(% colspan="2" %)(((
18 18  **IN_2PT part**
19 19  
... ... @@ -60,95 +60,3 @@
60 60  
61 61  sensor signal output negative
62 62  )))
63 -
64 -(% class="table-bordered" %)
65 -|**Indicator lamp**|**Description**
66 -|PWR|ON when power-on (when the program is running, it will be ON).
67 -|COM|It flashes when communicating with PLC normally, and it is OFF when timeout.
68 -|CH1|Channel 1 lamp: Always on in range; Flashing outside the range of -100℃to600℃; Off when the channel is closed.
69 -|CH2|Channel 2 lamp: Always on in range; Flashing outside the range of -100℃to600℃; Off when the channel is closed.
70 -|CH3|(((
71 -Channel 3 lamp: Set the digital value 0to 2000 (4mA) to 20mA) to be always on; Flashes outside the digital value 0 to2000 (4mA to 20mA).
72 -
73 -When the channel is open, the light is on, and the current is output; When the channel is closed, the light is off, and the current is not output (approaching 0).
74 -)))
75 -|CH4|(((
76 -Channel 4 lamp: Set the digital value 0to 2000 (4mA) to 20mA) to be always on; Flashes outside the digital value 0 to2000 (4mA to 20mA).
77 -
78 -When the channel is open, the light is on, and the current is output; When the channel is closed, the light is off, and the current is not output (approaching 0).
79 -)))
80 -
81 -= 3. ** Specification** =
82 -
83 -~1. General specification: Same as PLC main unit. (Please refer to the accompanying manual of the PLC main unit.)
84 -
85 -2. Power supply specification: The power supply is provided internally by PLC.
86 -
87 -3. Performance specifications:
88 -
89 -(% class="table-bordered" %)
90 -|**Project**|(% colspan="2" %)**Description**
91 -|Power supply|(% colspan="2" %)24VDC±10%, 50mA; 5VDC±10%, 70mA (The power supply is provided internally by host)
92 -|(% colspan="3" %)**PT part**
93 -|Analog input signal|(% colspan="2" %)Platinum thermal resistance PT100 sensor (100Ω), 3-wire, 2-channel input (CH1, CH2)
94 -|Sensor current|(% colspan="2" %)1mA sensor: 100 Ω (PT100)
95 -|Compensation range|-100 ℃ to 600 ℃ (recommended range)|Over range display: 32767
96 -|Digital output|(% colspan="2" %)-1000 to 6000 (unit 0.1 ℃)
97 -|Measurement accuracy|(% colspan="2" %)0.2℃ to 0.3℃
98 -|Total accuracy|(% colspan="2" %)Full range ±0.5% (compensation range)
99 -|Conversion speed|(% colspan="2" %)2 channels 50ms
100 -|Conversion features|(% colspan="2" %)[[image:image-20221222110430-1.png]]
101 -|(% colspan="3" %)**DAI section**
102 -|Rated range|(% colspan="2" %)0 to 2000: 4mA to 20mA
103 -|Analog output range|(% colspan="2" %)DC 4mA to 20mA (external load resistance ≤ 500 Ω)
104 -|Digital output|(% colspan="2" %)12-bit binary
105 -|Resolution|(% colspan="2" %)8uA (4mA to 20mA/2000)
106 -|Comprehensive precision|(% colspan="2" %)±0.5% of full scale (4mA to 20mA: ±0.08 mA)
107 -|D/A conversion time|(% colspan="2" %)One scan cycle (D/A conversion after ladder diagram END instruction is executed, and BD channel output value is updated)
108 -|Output features|(% colspan="2" %)(((
109 -External load is 250Ω. 0 to 2000 was converted to 4mA to 20mA.
110 -
111 -[[image:image-20221222110430-2.png]]
112 -)))
113 -|Points occupied|(% colspan="2" %)0 point (2DAI is not affected by the standard maximum control points of the main PLC because it is operated through the data register)
114 -
115 -= **4.  Wiring ** =
116 -
117 -**Wiring instructions:**
118 -
119 -1. 2-wire PT100: When using channel 1, L1- and VI- are shorted with wires, and the two leads of the sensor are connected to L1+ and LI- respectively. Similarly, when using channel 2, L2- and VI- are shorted with wires, and the two leads of the sensor are connected to L2+ and L2- respectively.
120 -1. 3-wire PT100: When using channel 1, two leads of the same color are connected to L1- and VI- respectively, and the other lead of different color is connected to L1+. Channel 2 is connected in the same way.
121 -
122 -|[[image:image-20221222110545-3.png]]
123 -|Cut off the power before installing, removing or wiring the BD board to avoid electric shock or product damage.
124 -
125 -**✎Note:**
126 -
127 -*
128 -** Do not place signal cables near high voltage power cables or in the same trunk line. Otherwise, it may be disturbed or surged. Keep a safe distance between signal cable and power cable, at least 100mm.
129 -** Ground the shielding of shielded wire or shielded cable. But the ground point and high voltage line cannot be the same.
130 -** Do not connect cables of impermissible size to avoid poor contact or product damage.
131 -** Fix the cable so that no force directly acts on the terminal line or cable connection area.
132 -** The tightening torque of terminal is 0.5Nm to 0.6N.m. Please tighten it to prevent malfunction.
133 -** Do not use empty terminals.
134 -
135 -=== **4.1 Applicable cables** ===
136 -
137 -~1. AWG25-16 is used for connection with output device.
138 -
139 -2. Maximum terminal tightening torque is 0.5N.m to 0.6N.m.
140 -
141 -3. Using different types of cables may cause poor contact with terminals. Please use pressfit terminals for good contact.
142 -
143 -**Line number and cross-sectional area**
144 -
145 -|**Line number**|**Cross-sectional area (mm^^2^^)**|**End processing**
146 -|AWG26|0.1288|(% rowspan="3" %)(((
147 -Stranded cable: Strip off the sheath, rub the core wire, and then connect the cable.
148 -
149 -Single-core cable: Strip off the sheath and connect the cable.
150 -)))
151 -|...|...
152 -|AWG16|1.309
153 -
154 -[[image:image-20221222110656-4.png]]
image-20221222110430-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -41.0 KB
Content
image-20221222110430-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -51.1 KB
Content
image-20221222110545-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -5.3 KB
Content
image-20221222110656-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -1.8 KB
Content