Changes for page LX5V-2PT2DAI
Last modified by WeconTurkey on 2024/10/16 22:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -13,7 +13,6 @@ 13 13 14 14 [[image:image-20221222110100-1.png]] 15 15 16 -(% class="table-bordered" %) 17 17 |(% colspan="2" %)((( 18 18 **IN_2PT part** 19 19 ... ... @@ -60,95 +60,3 @@ 60 60 61 61 sensor signal output negative 62 62 ))) 63 - 64 -(% class="table-bordered" %) 65 -|**Indicator lamp**|**Description** 66 -|PWR|ON when power-on (when the program is running, it will be ON). 67 -|COM|It flashes when communicating with PLC normally, and it is OFF when timeout. 68 -|CH1|Channel 1 lamp: Always on in range; Flashing outside the range of -100℃to600℃; Off when the channel is closed. 69 -|CH2|Channel 2 lamp: Always on in range; Flashing outside the range of -100℃to600℃; Off when the channel is closed. 70 -|CH3|((( 71 -Channel 3 lamp: Set the digital value 0to 2000 (4mA) to 20mA) to be always on; Flashes outside the digital value 0 to2000 (4mA to 20mA). 72 - 73 -When the channel is open, the light is on, and the current is output; When the channel is closed, the light is off, and the current is not output (approaching 0). 74 -))) 75 -|CH4|((( 76 -Channel 4 lamp: Set the digital value 0to 2000 (4mA) to 20mA) to be always on; Flashes outside the digital value 0 to2000 (4mA to 20mA). 77 - 78 -When the channel is open, the light is on, and the current is output; When the channel is closed, the light is off, and the current is not output (approaching 0). 79 -))) 80 - 81 -= 3. ** Specification** = 82 - 83 -~1. General specification: Same as PLC main unit. (Please refer to the accompanying manual of the PLC main unit.) 84 - 85 -2. Power supply specification: The power supply is provided internally by PLC. 86 - 87 -3. Performance specifications: 88 - 89 -(% class="table-bordered" %) 90 -|**Project**|(% colspan="2" %)**Description** 91 -|Power supply|(% colspan="2" %)24VDC±10%, 50mA; 5VDC±10%, 70mA (The power supply is provided internally by host) 92 -|(% colspan="3" %)**PT part** 93 -|Analog input signal|(% colspan="2" %)Platinum thermal resistance PT100 sensor (100Ω), 3-wire, 2-channel input (CH1, CH2) 94 -|Sensor current|(% colspan="2" %)1mA sensor: 100 Ω (PT100) 95 -|Compensation range|-100 ℃ to 600 ℃ (recommended range)|Over range display: 32767 96 -|Digital output|(% colspan="2" %)-1000 to 6000 (unit 0.1 ℃) 97 -|Measurement accuracy|(% colspan="2" %)0.2℃ to 0.3℃ 98 -|Total accuracy|(% colspan="2" %)Full range ±0.5% (compensation range) 99 -|Conversion speed|(% colspan="2" %)2 channels 50ms 100 -|Conversion features|(% colspan="2" %)[[image:image-20221222110430-1.png]] 101 -|(% colspan="3" %)**DAI section** 102 -|Rated range|(% colspan="2" %)0 to 2000: 4mA to 20mA 103 -|Analog output range|(% colspan="2" %)DC 4mA to 20mA (external load resistance ≤ 500 Ω) 104 -|Digital output|(% colspan="2" %)12-bit binary 105 -|Resolution|(% colspan="2" %)8uA (4mA to 20mA/2000) 106 -|Comprehensive precision|(% colspan="2" %)±0.5% of full scale (4mA to 20mA: ±0.08 mA) 107 -|D/A conversion time|(% colspan="2" %)One scan cycle (D/A conversion after ladder diagram END instruction is executed, and BD channel output value is updated) 108 -|Output features|(% colspan="2" %)((( 109 -External load is 250Ω. 0 to 2000 was converted to 4mA to 20mA. 110 - 111 -[[image:image-20221222110430-2.png]] 112 -))) 113 -|Points occupied|(% colspan="2" %)0 point (2DAI is not affected by the standard maximum control points of the main PLC because it is operated through the data register) 114 - 115 -= **4. Wiring ** = 116 - 117 -**Wiring instructions:** 118 - 119 -1. 2-wire PT100: When using channel 1, L1- and VI- are shorted with wires, and the two leads of the sensor are connected to L1+ and LI- respectively. Similarly, when using channel 2, L2- and VI- are shorted with wires, and the two leads of the sensor are connected to L2+ and L2- respectively. 120 -1. 3-wire PT100: When using channel 1, two leads of the same color are connected to L1- and VI- respectively, and the other lead of different color is connected to L1+. Channel 2 is connected in the same way. 121 - 122 -|[[image:image-20221222110545-3.png]] 123 -|Cut off the power before installing, removing or wiring the BD board to avoid electric shock or product damage. 124 - 125 -**✎Note:** 126 - 127 -* 128 -** Do not place signal cables near high voltage power cables or in the same trunk line. Otherwise, it may be disturbed or surged. Keep a safe distance between signal cable and power cable, at least 100mm. 129 -** Ground the shielding of shielded wire or shielded cable. But the ground point and high voltage line cannot be the same. 130 -** Do not connect cables of impermissible size to avoid poor contact or product damage. 131 -** Fix the cable so that no force directly acts on the terminal line or cable connection area. 132 -** The tightening torque of terminal is 0.5Nm to 0.6N.m. Please tighten it to prevent malfunction. 133 -** Do not use empty terminals. 134 - 135 -=== **4.1 Applicable cables** === 136 - 137 -~1. AWG25-16 is used for connection with output device. 138 - 139 -2. Maximum terminal tightening torque is 0.5N.m to 0.6N.m. 140 - 141 -3. Using different types of cables may cause poor contact with terminals. Please use pressfit terminals for good contact. 142 - 143 -**Line number and cross-sectional area** 144 - 145 -|**Line number**|**Cross-sectional area (mm^^2^^)**|**End processing** 146 -|AWG26|0.1288|(% rowspan="3" %)((( 147 -Stranded cable: Strip off the sheath, rub the core wire, and then connect the cable. 148 - 149 -Single-core cable: Strip off the sheath and connect the cable. 150 -))) 151 -|...|... 152 -|AWG16|1.309 153 - 154 -[[image:image-20221222110656-4.png]]
- image-20221222110430-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Jim - Size
-
... ... @@ -1,1 +1,0 @@ 1 -41.0 KB - Content
- image-20221222110430-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Jim - Size
-
... ... @@ -1,1 +1,0 @@ 1 -51.1 KB - Content
- image-20221222110545-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Jim - Size
-
... ... @@ -1,1 +1,0 @@ 1 -5.3 KB - Content
- image-20221222110656-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Jim - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.8 KB - Content