... ... @@ -7,4 +7,22 @@
7 7  
8 8  
9 9  
10 +**Troubleshooting**
11 +
12 +|=**Reason**|=**Troubleshooting methods**|=**Handling**
13 +|Internal brake resistance wiring error|Check whether C, D are connected to the short cap and the contact is normal|When using an internal braking resistor, reliably connect the shorting cap or shorting wire between C and D
14 +|External braking resistor wiring error|Check whether the external resistor is connected reliably between P+ and C.|When using an external braking resistor, the external resistor is reliably strung between P+ and C
15 +|**Internal braking resistor damaged**|**The servo drive is powered off. Detects whether the resistance between P+ and D is 50Ω**|(((
16 +Contact the technician to replace the internal braking resistor.
17 +
18 +Use an external braking resistor and change the relevant parameters of the P00 "Basic Settings".
19 +)))
20 +
21 +
22 +
23 +**How Can you measure 50 Ohm resistance between P+ and D terminal ? **
24 +
25 +
26 +**Video Link :** [[https:~~/~~/workdrive.zoho.in/file/zotk832e1aa6b63f24c9fb85c4fa2c98b752f>>https://workdrive.zoho.in/file/zotk832e1aa6b63f24c9fb85c4fa2c98b752f]]
27 +
10 10