... ... @@ -814,9 +814,6 @@
814 814  Precautions
815 815  
816 816  * This function block is not available when the axis does not exist.
817 -* In profile mode, the STOP command requires the mapper to map the PDOs of 0x6060, 0x6061, 0x60FF, and 0x606C for normal operation;
818 -* In CST/CSV mode, triggering STOP switches to synchronous velocity mode;
819 -* In CST/CSV mode, the STOP command requires the mapper to map the PDOs of 0x6060, 0x6061, 0x60FF, and 0x606C for normal operation;
820 820  