Changes for page 03 Project Settings

Last modified by Hunter on 2024/06/11 15:58

From version 11.13
edited by Stone Wu
on 2022/08/08 10:13
Change comment: (Autosaved)
To version 30.3
edited by Mora Zhou
on 2023/09/09 14:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Mora
Content
... ... @@ -4,7 +4,7 @@
4 4  
5 5  **Operating procedure**
6 6  
7 -Click "Project"->"Communication" to open setting window.
7 +Click "Project""Communication" to open setting window.
8 8  
9 9  (% style="text-align:center" %)
10 10  [[image:image-20220614172512-1.png]]
... ... @@ -43,7 +43,7 @@
43 43  == Project settings ==
44 44  
45 45  (% style="text-align:center" %)
46 -[[image:工程设置 1.png||class="img-thumbnail"]]
46 +[[image:ProjectSettingOverview.png]]
47 47  
48 48  == HMI model ==
49 49  
... ... @@ -83,6 +83,19 @@
83 83  ✎**Note**: When the Screensaver and the Screen Lock are enabled at the same time, the Screensaver can only be unlocked after unlocking the Screen Lock.
84 84  )))
85 85  
86 +== Enable Dynamic Screensaver ==
87 +
88 +Same as Screensaver. Dynamic Screensaver provides the function is that prevent the HMI from displaying the same screen for a long time due to unattended operation. But Dynamic will be able to display animation.
89 +
90 +(% style="text-align:center" %)
91 +[[image:DynamicScreensaver.png]]
92 +
93 +**Enable dynamic screensaver:** If the screen is not operated within the set waiting time, it will automatically enter the set animation effect, and operating the screen again will exit the dynamic screensaver.
94 +
95 +**Standby Time(minutes): **When the screen is not operated, the waiting interval to enter the dynamic screensaver, ranges 1~~720.
96 +
97 +**Animation Type:** Types of effects currently provided are Raster, Blinds, and Bubble.
98 +
86 86  == Initial screen ==
87 87  
88 88  The "Initial screen" provides the interface to user to set initial screen. Initial screen means the first one displayed screen when HMI is powered on.
... ... @@ -92,9 +92,9 @@
92 92  
93 93  **Operating Procedure**
94 94  
95 -1. Open [Project Settings] windows.
108 +1. Open "Project Settings" windows.
96 96  1. Select initial screen in drop-list, use screen 2 as an example.
97 -1. Click [OK] button to save setting and exit windows.
110 +1. Click "OK" button to save setting and exit windows.
98 98  
99 99  == Operation record ==
100 100  
... ... @@ -118,8 +118,6 @@
118 118  
119 119  == Switch action ==
120 120  
121 -**Introduction**
122 -
123 123  The "Switch action" provides the action trigger settings. It is the effect timing of when the button executes the action.
124 124  
125 125  (% style="text-align:center" %)
... ... @@ -222,7 +222,7 @@
222 222  1. Open "HMI IP" sub-window.
223 223  1. Check "HMI IP".
224 224  1. Enter IP.
225 -1. {{id name="_Toc479868176"/}}{{id name="_Toc8172"/}}Click "OK" button to save setting and exit windows.
236 +1. Click "OK" button to save setting and exit windows.
226 226  
227 227  == Remote access password ==
228 228  
... ... @@ -234,7 +234,7 @@
234 234  **Operating Procedure**
235 235  
236 236  1. Open "Project Settings" windows;
237 -1. Open "HMI IP] sub-windows;
248 +1. Open "HMI IP" sub-windows;
238 238  1. Enter password;
239 239  1. Click "OK" button to save setting and exit windows;
240 240  
... ... @@ -259,7 +259,7 @@
259 259  The expiry time and key of each period could not be empty, and they need to be configured in advance. And the expiry time of the latter period need to be later than the expiry of the previous period.
260 260  
261 261  1. **Use admin key: **It can be used for unlock all expirations,in addition to each period key.If users select [use admin key] function,once users enter the admin key when HMI expires,the installment payment function will be disabled.
262 -1. **Admin: **Password (Key) for [use admin key];
273 +1. **Admin: **Password (Key) for "use admin key";
263 263  1. **Max periods: **The period of static installment payment range is 0-12.When the maximum number of period is 0,it means that the instalment payment function is disabled;
264 264  1. **Begin Period: **Set the installment payment to start from the first period, the range is 1-13;
265 265  1. **List: **Configure a list based on [Maximum Periods] and [Begin Period],where user can configure the password and expiration time for each period.
... ... @@ -343,13 +343,13 @@
343 343  
344 344  1. Open "Project Settings" windows.
345 345  1. Open "Extend" sub-windows.
346 -1. Select "Startup" or [Running.
357 +1. Select "Startup" or "Running".
347 347  1. Set "Time".
348 348  1. Set "Password" if you require the password when entering the backstage interface.
349 349  
350 350  == Special expansion ==
351 351  
352 -"Special Expansion" is for extending audio play and camera input functions for special HMI models.
363 +"Special expansion" is for extending audio play and camera input functions for special HMI models.
353 353  
354 354  (% style="text-align:center" %)
355 355  [[image:05.Project Settings_html_784d40de9b3e3bda.png||height="109" width="543"]]
... ... @@ -386,8 +386,8 @@
386 386  
387 387  * These all three functions are not available for all HMIs, only special HMI models could support them.
388 388  * The details of "audio" settings, please refer to [[Audio>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HAudio]].
389 -* The details of ""camera" settings, please refer to [[camera>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HrtspwebA0camera]].
390 -* The details of ""mulit-link" settings, please refer to [[mulit-link>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HMulit-link]].
400 +* The details of "camera" settings, please refer to [[camera>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HrtspwebA0camera]].
401 +* The details of "mulit-link" settings, please refer to [[mulit-link>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HMulit-link]].
391 391  )))
392 392  
393 393  == Input device ==
... ... @@ -408,6 +408,112 @@
408 408  
409 409  The arrow will be display in screen when HMI is running, and keyboard could be used to enter code and control arrow.
410 410  
422 +**HotKey Configuration Description**  
423 +
424 +**Enable function**
425 +
426 + Select “Expansion" of "System Configuration"/"Engineering Parameters" in the toolbar of SACDA, and enable the keyboard before enabling the hotkeys, as shown in the following figure.
427 +
428 +(% style="text-align:center" %)
429 +[[image:57.jpg]]
430 +
431 +**Hotkey configuration**
432 +
433 + (1) Check the "HotKey Configuration" function. When the external keyboard is enabled, the hotkey function can be customized. By configuring the lua script corresponding to each hotkey, the specific functions can be executed after the hotkey is triggered.
434 +
435 +(% style="text-align:center" %)
436 +[[image:58.jpg]]
437 +
438 +|System shortcut keys|Features
439 +|(% rowspan="4" %)Shift+ "↓"|(((
440 +Switch mouse mode: Default mode: The mouse can move freely.
441 +
442 +This mode is only valid when the project configuration displays the mouse;
443 +)))
444 +|Switch mouse mode: The selected box mode. The border of the selected part is set red;
445 +|Switch mouse mode: The selected grayed out mode ,the selected part gray out;
446 +|Switch mouse mode: Mouse selected mode. The mouse rests on the selected part. This mode is only valid when the project configuration displays the mouse;
447 +|(% rowspan="5" %)Up, down, left and right direction keys|In the mouse movement mode, the free movement of the mouse cursor can be controlled;
448 +|In the mouse selected mode, the mouse cursor can be controlled to move directly to the center position of the specified parts of the current screen;
449 +|In the selected box mode, the selected parts of the current picture can be switched. The border of selected parts will be set red;
450 +|In the selected grayed out mode, the selected parts of the current picture can be switched. The selected parts will be grayed out;
451 +|In the mouse selected mode, selected box mode, selected grayed out mode, the types of widgets that support toggling selected widgets are bit switches, word switches, function switches, word status, super combination buttons, value inputs, text inputs, and lua custom;
452 +|Backspace|Backspace function in keyboard;
453 +|Spacebar|The first option is selected by default in the left and right option bars of the T9 keyboard;
454 +|Shift+ "↑"|SwitchT9keyboard input method mode;
455 +|Shift+ “←”|SwitchT9keyboard symbol mode;
456 +|Numbers 1-6 on the left side of the keyboard|6options corresponding to the left and right option bars of the T9 keyboard;
457 +|F1~~F6|6options corresponding to the left and right option bars of the T9 keyboard;
458 +|The "-" key next to Backspace|Left page turning of left and right option bars of T9 keyboard;
459 +|F7|Left page turning of left and right option bars of T9 keyboard;
460 +|The "+" key next to Backspace|Right page turning of left and right option bars of T9 keyboard;
461 +|F8|Right page turning of left and right option bars of T9 keyboard;
462 +|Shift+ "F7"|Page up of the upper and lower option columns of the T9 keyboard;
463 +|Shift+ "F8"|Page down of the upper and lower option columns of the T9 keyboard;
464 +|Shift+ "F1 ~~ F3"|3options corresponding to the up and down option bars of the T9 keyboard;
465 +|Shift+ "Backspace"|Same as esc, exit the keyboard;
466 +|Shift+Number and special symbol keys on the left side of the keyboard|Realize special character input, such as: ~~! @ # $% ^&* () _ + {}: "<>?
467 +|Ctrl + Shift (press Ctrl before Shift)|SwitchT9Pinyin, alphabet and number modes of keyboard;
468 +|Shift+Letter|In the lowercase mode of the keyboard: Shift +Letter, which can enter uppercase; In the uppercase mode: Shift +Letter, which can enter lowercase;
469 +|Num Lock|When the corresponding indicator light is not on, the keypad numbers are not allowed to be input;
470 +|(% rowspan="3" %)Enter|In the mouse movement mode and the mouse selected mode, press the Enter key, which indicates that it clicks at the mouse cursor position. (Corresponding to the press, lift and click event);
471 +|In the selected box mode and selected grayed out mode, select the object and then press the Enter key, which indicates that clicking triggers the center position of the selected area;
472 +|In the keyboard screen and not entering the mouse selected mode, the selected box mode, the selected gray-out mode. Press the Enter key, indicating that the input is completed;
473 +|Caps Lock|Switch letter case modes of the 1001and 1003 built-in keyboard. Lighting represents switching to the uppercase mode;
474 +
475 +**System shortcut keys**
476 +
477 +HMI screen itself comes with supported shortcut key function.
478 +
479 +|HSW1892|Polling time interval setting for keyboard keys|(((
480 +~= 0,50ms;
481 +
482 +~= 1,40ms;
483 +
484 +~= 2,30ms;
485 +
486 +~= 3,20ms;
487 +
488 +~= 4,10ms;
489 +)))
490 +|HSW1893|Cursor mode switching|(((
491 +~= 0, Default free mode;
492 +
493 +~= 1, the selected box mode;
494 +
495 +~= 2, the selected grayed out mode;
496 +
497 +~= 3, Mouse selected mode;
498 +)))
499 +|HSW1894|Enable specific serial keyboard|(((
500 +~= 1Enable;
501 +
502 +~=Others, disabled;
503 +
504 +{{info}}
505 +✎Note: Only initialization is valid, and it is recommended to use it in background initialization script;
506 +{{/info}}
507 +)))
508 +|HSW1895|Control whether keyboard keys take effect under certain circumstances|(((
509 +~= 0, When default screen rest and screensaver status, the button trigger does not take effect;
510 +
511 +~= 1: HSX1895.0=1. The button trigger will take effect when it is in the screen rest status;
512 +
513 +~= 2: HSX1895.1=1. The button trigger will take effect when it is in the screensaver status;
514 +)))
515 +|HSW10611|Set up server|(((
516 +~=0: Select the server configured in "Project Parameters"
517 +
518 +~=1: Select server 1
519 +
520 +~=2: Select server 2
521 +)))
522 +|HSW11767|Remote screen display adaptation mode switching  |= 0: Default mode. Horizontal screen project remote full screen zoom display; Vertical screen project remote zoom display in equal proportion;
523 +~= 1: Full-screen zoom display;
524 +~~~= 2: According to the screen size ratio, zoom display in equal proportion;
525 +
526 += 3: According to the screen pixels, no zoom display; =
527 +
411 411  == Lab ==
412 412  
413 413  Lab is used for enable experimental function.
... ... @@ -466,7 +466,7 @@
466 466  == FTP server ==
467 467  
468 468  (% style="text-align:center" %)
469 -[[image:image-20220808093816-5.png]]
586 +[[image:image-20220808093816-5.png||class="img-thumbnail"]]
470 470  
471 471  **Enable method: **"Project parameter" → "Extend" → check "FTP service".
472 472  
... ... @@ -474,11 +474,13 @@
474 474  
475 475  * Enter "ftp:~/~/ + the IP address of the HMI" in the folder address bar.
476 476  
477 -[[image:image-20220808094729-7.png]]
594 +(% style="text-align:center" %)
595 +[[image:image-20220808094729-7.png||height="429" width="909" class="img-thumbnail"]]
478 478  
479 479  * You can also enter “ftp:~/~/ftpuser:000000@192.168.39.242” to access the interface directly (with a username and password).
480 480  
481 -[[image:image-20220808100330-10.jpeg]]
599 +(% style="text-align:center" %)
600 +[[image:image-20220808100330-10.jpeg||class="img-thumbnail"]]
482 482  
483 483  * If the ftp service is enabled, it will prompt for a username and password, and if not, it will prompt that the connection to the server cannot be established.
484 484  
... ... @@ -488,7 +488,7 @@
488 488  * Enter the username and password as configured in the project.
489 489  
490 490  (% style="text-align:center" %)
491 -[[image:image-20220808100720-11.jpeg]]
610 +[[image:image-20220808100720-11.jpeg||class="img-thumbnail"]]
492 492  
493 493  **Description of folder and permission**
494 494  
... ... @@ -496,27 +496,28 @@
496 496  * DataLogFile is data log record. It can only download files, but cannot upload files.
497 497  * RecipeFile is recipe. It can only download files, but cannot upload files.
498 498  * UserMgrFile is operation record. It can only download files, but cannot upload files.
499 -* Sdcard is the mounting directory of SD card the SD card will be connected to the S1 ~~ Sn subdirectory, you can upload and download.
618 +* Sdcard is the mounting directory of SD card. There will be the subdirectory of S1, S2, S3, etc. when connected SD card. It can upload and download.
619 +* Udisk is the mounting directory of USB flash drive. There will be the subdirectory of U1, U2, U3, etc. when connected USB flash drive. It can upload and download.
500 500  
501 - Note: U disk and SD card is recommended to use NTFS format.
621 +(% class="box infomessage" %)
622 +(((
623 +**✎Note:** For Udisk and SD card, it is recommended to use NTFS format.
624 +)))
502 502  
503 - ⑥. Maximum number of connections: Only 5 clients can be supported at the same time to access the interface.
626 +Maximum number of connections: up to 5 clients can be supported to access the interface at the same time.
504 504  
505 - ⑦. Password modification: Use the changePsd function in the lua function ftpserver library to make changes.
628 +Password modification: Use the changePsd function in the lua function ftpserver library to modify password.
506 506  
507 - Prototype: ftpserver.changePsd(oldPsd,newPsd)
630 +* Prototype: ftpserver.changePsd(oldPsd,newPsd)
631 +* Function: change the login password of ftpserver
632 +* Parameters:
633 +** oldPsd(string) old password
634 +** newPsd(string) new password.
635 +* Format: only letters, numbers and underscores are allowed, and the length must be 6 to 8 digits.
636 +* Returns.
637 +** Success: true
638 +** Failure: nil,err
508 508  
509 - Function: change the login password of ftpserver
510 -
511 - Parameters: oldPsd(string) old password, newPsd(string) new password. Format: only letters, numbers and underscores are allowed, and the length must be 6-8 digits.
512 -
513 - Returns.
514 -
515 - Success: true
516 -
517 - Failure: nil,err
518 -
519 -
520 520  = **Security** =
521 521  
522 522  Security means objects and screen security, but this function is only available in 3000i series and HMI+ series or above.
... ... @@ -524,34 +524,32 @@
524 524  Only when object password is set,object password function could be used in object.
525 525  
526 526  (% style="text-align:center" %)
527 -[[image:安全设置 1.png||class="img-thumbnail"]]
647 +[[image:SecurityOverview.png]]
528 528  
529 529  == Objects password ==
530 530  
531 -You should enter password to access the protected object. This could avoid some misoperation on object. There are 12 levels in object password setting, and each level corresponds to each password.
651 +Users should enter password to access the protected object. This could avoid some misoperation on object. There are 12 levels in object password setting, and each level corresponds to each password.
532 532  
533 533  (% style="text-align:center" %)
534 534  [[image:05.Project Settings_html_4835fff86888a26b.png||height="238" width="502"]]
535 535  
536 -**Enable object password: **Check it to enable object security function. There are 12 levels corresponding to different passwords. The password of levels are set by the highest level.
656 +**Enable object password: **Check it to enable object security function. There are 12 levels corresponding to different passwords. The password of levels is set by the highest level.
537 537  
538 -1. **Passwords for levels:** It is used for set password for every level, it is composed of numbers and letters (case sensitive)within 8 digits.
539 -1. **Start level:** It is used for set initial level while this function is enabled.
540 -1. **Highest level**: It is used for set how many levels of password could be used.
541 -1. **Independent password:**
658 +* **Passwords for levels:** It is used to set password for every level, it is composed of numbers and letters (case sensitive)within 8 digits.
659 +* **Start level:** It is used to set initial level while this function is enabled.
660 +* **Highest level**: It is used to set how many levels of password could be used.
661 +* **Independent password:**
662 +** **Unchecked: **You should enter the corresponding level password when unlocking each level of object, and the higher level password could unlock the lower level object.
663 +** **Checked:** You could only type the corresponding level password when unlocking each level of object.
542 542  
543 -* **Unchecked: **You should enter the corresponding level password when unlocking each level of object, and the higher level password could unlock the lower level object.
544 -* **Checked:** You could only type the corresponding level password when unlocking each level of object.
665 +(% class="box infomessage" %)
666 +**Note: **Object level password could be enabled in "Bit Switch", "Word Switch", "Function Switch", combination "Switch", "Numeric Input", "Character Input", "Drop-down List" etc.
545 545  
546 -✎**Note:**
547 -
548 -* Object level password could be enabled in "Bit Switch", "Word Switch", "Function Switch", vCombination Switch", "Numeric Input", "Character Input", "Drop-down List" etc.
549 -
550 550  (% style="text-align:center" %)
551 551  [[image:安全设置 2.png||class="img-thumbnail"]]
552 552  
553 -* The configured password could not be empty, otherwise when users close the configuration screen ,there will be an error: "please set password for level".
554 -* If configured object password level is higher than highest password setting in Project Settingss, there will be an error note during compiling: "the security level of this object is out of range!" .Users need to set password level again to solve the problem.
671 +* The configured password could not be empty, otherwise, when users close the configuration screen, there will be an error: "Please set password for level".
672 +* If configured object password level is higher than highest password setting in Project Settingss, there will be an error note during compiling: "The security level of this object is out of range!" . Users need to set password level again to solve the problem.
555 555  
556 556  == Screen Lock ==
557 557  
... ... @@ -564,6 +564,47 @@
564 564  1. **Password:** this password is used for unlocking screen, it is composed of numbers and letters (case sensitive) within 8 digits.
565 565  1. **Lock time:** It is used for setting time how long the screen will be locked if users do not operate, range: 1 to 240 minutes (integer).
566 566  
685 +== LAN Monitoring Security ==
686 +
687 +(% style="text-align:center" %)
688 +[[image:SecurityOption.png]]
689 +
690 +In the same Local Area Network, user can enter the IP of the HMI on the webpage to achieve LAN monitoring of the HMI
691 +
692 +The terminal access number of remote monitoring or LAN monitoring for each series of HMI models is limited, as following table shows:
693 +
694 +|=(% scope="row" style="width: 182px;" %)Model|=(% style="width: 178px;" %)System Version|=(% style="width: 153px;" %)LAN Monitoring|=(% style="width: 260px;" %)Remote Monitoring|=(% style="width: 241px;" %)Supported visits number
695 +|=(% style="width: 182px;" %)3000|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
696 +|=(% style="width: 182px;" %)3000i|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
697 +|=(% style="width: 182px;" %)3000ie|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
698 +|=(% style="width: 182px;" %)3000ig-O|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
699 +|=(% style="width: 182px;" %)3000ig/3000ig-C|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
700 +|=(% style="width: 182px;" %)8000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
701 +|=(% style="width: 182px;" %)8000ig|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
702 +|=(% style="width: 182px;" %)9000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
703 +
704 +After this function is enabled, user name and password need to be entered for LAN monitoring, which can avoid some uncontrollable security problems to a certain extent;
705 +
706 +{{info}}
707 +✎Note: This LAN Monitoring Security function is only supported by HMI V2.0 system and above.
708 +{{/info}}
709 +
710 +**Webpage monitoring**:
711 +
712 +After enable this function, when user input IP to access HMI, you need to enter the user name and password configured by HMI in the login interface first, and then you can access after verification(The login interface supports switching language between Chinese and English, the default is Chinese)
713 +
714 +(% style="text-align:center" %)
715 +[[image:LANSercuityloginpage.png]]
716 +
717 +If it is not configured this function in the project, it also can modify from the background interface.
718 +
719 +System->Extend
720 +
721 +(% style="text-align:center" %)
722 +[[image:LANBackground.png]]
723 +
724 +
725 +
567 567  = Font pack =
568 568  
569 569  "Font pack" is for setting built-in font for HMI project, in this way, the text in some objects of the HMI could be displayed in the desired font.
... ... @@ -584,7 +584,7 @@
584 584  [[image:image-20220614173008-2.png]]
585 585  
586 586  (% start="5" %)
587 -1. Click [OK] to save settings.
746 +1. Click OK to save settings.
588 588  
589 589  **Result**
590 590  
56.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Mora
Size
... ... @@ -1,0 +1,1 @@
1 +64.3 KB
Content
57.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Mora
Size
... ... @@ -1,0 +1,1 @@
1 +123.6 KB
Content
58.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Mora
Size
... ... @@ -1,0 +1,1 @@
1 +135.1 KB
Content
DynamicScreensaver.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +2.7 KB
Content
LANBackground.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +652.7 KB
Content
LANSercuityloginpage.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +68.1 KB
Content
ProjectSettingOverview.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +26.1 KB
Content
SecurityOption.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +2.0 KB
Content
SecurityOverview.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +20.0 KB
Content