Changes for page 03 Project Settings

Last modified by Hunter on 2024/06/11 15:58

From version 13.1
edited by Stone Wu
on 2022/08/08 10:24
Change comment: There is no comment for this version
To version 18.2
edited by Hunter
on 2023/01/07 17:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Hunter
Content
... ... @@ -4,7 +4,7 @@
4 4  
5 5  **Operating procedure**
6 6  
7 -Click "Project"->"Communication" to open setting window.
7 +Click "Project""Communication" to open setting window.
8 8  
9 9  (% style="text-align:center" %)
10 10  [[image:image-20220614172512-1.png]]
... ... @@ -43,7 +43,7 @@
43 43  == Project settings ==
44 44  
45 45  (% style="text-align:center" %)
46 -[[image:工程设置 1.png||class="img-thumbnail"]]
46 +[[image:ProjectSettingOverview.png]]
47 47  
48 48  == HMI model ==
49 49  
... ... @@ -83,6 +83,20 @@
83 83  ✎**Note**: When the Screensaver and the Screen Lock are enabled at the same time, the Screensaver can only be unlocked after unlocking the Screen Lock.
84 84  )))
85 85  
86 +(% class="wikigeneratedid" %)
87 +== Enable Dynamic Screensaver ==
88 +
89 +Same to Screensaver. Dynamic Screensaver provides the function is that prevent the HMI from displaying the same screen for a long time due to unattended operation. But the Dynamic will be able to display animation.
90 +
91 +(% style="text-align:center" %)
92 +[[image:DynamicScreensaver.png]]
93 +
94 +**Enable dynamic screensaver:** If the screen is not operated within the set waiting time, it will automatically enter the set animation effect, and operating the screen again will exit the dynamic screensaver;
95 +
96 +**Standby Time(minutes): **When the screen is not operated, the waiting interval to enter the dynamic screensaver, ranges 1~~720;
97 +
98 +**Animation Type:** Types of effects currently provided are Raster, Blinds, Bubble.
99 +
86 86  == Initial screen ==
87 87  
88 88  The "Initial screen" provides the interface to user to set initial screen. Initial screen means the first one displayed screen when HMI is powered on.
... ... @@ -92,9 +92,9 @@
92 92  
93 93  **Operating Procedure**
94 94  
95 -1. Open [Project Settings] windows.
109 +1. Open "Project Settings" windows.
96 96  1. Select initial screen in drop-list, use screen 2 as an example.
97 -1. Click [OK] button to save setting and exit windows.
111 +1. Click "OK" button to save setting and exit windows.
98 98  
99 99  == Operation record ==
100 100  
... ... @@ -222,7 +222,7 @@
222 222  1. Open "HMI IP" sub-window.
223 223  1. Check "HMI IP".
224 224  1. Enter IP.
225 -1. {{id name="_Toc479868176"/}}{{id name="_Toc8172"/}}Click "OK" button to save setting and exit windows.
239 +1. Click "OK" button to save setting and exit windows.
226 226  
227 227  == Remote access password ==
228 228  
... ... @@ -234,7 +234,7 @@
234 234  **Operating Procedure**
235 235  
236 236  1. Open "Project Settings" windows;
237 -1. Open "HMI IP] sub-windows;
251 +1. Open "HMI IP" sub-windows;
238 238  1. Enter password;
239 239  1. Click "OK" button to save setting and exit windows;
240 240  
... ... @@ -259,7 +259,7 @@
259 259  The expiry time and key of each period could not be empty, and they need to be configured in advance. And the expiry time of the latter period need to be later than the expiry of the previous period.
260 260  
261 261  1. **Use admin key: **It can be used for unlock all expirations,in addition to each period key.If users select [use admin key] function,once users enter the admin key when HMI expires,the installment payment function will be disabled.
262 -1. **Admin: **Password (Key) for [use admin key];
276 +1. **Admin: **Password (Key) for "use admin key";
263 263  1. **Max periods: **The period of static installment payment range is 0-12.When the maximum number of period is 0,it means that the instalment payment function is disabled;
264 264  1. **Begin Period: **Set the installment payment to start from the first period, the range is 1-13;
265 265  1. **List: **Configure a list based on [Maximum Periods] and [Begin Period],where user can configure the password and expiration time for each period.
... ... @@ -343,7 +343,7 @@
343 343  
344 344  1. Open "Project Settings" windows.
345 345  1. Open "Extend" sub-windows.
346 -1. Select "Startup" or [Running.
360 +1. Select "Startup" or "Running".
347 347  1. Set "Time".
348 348  1. Set "Password" if you require the password when entering the backstage interface.
349 349  
... ... @@ -386,8 +386,8 @@
386 386  
387 387  * These all three functions are not available for all HMIs, only special HMI models could support them.
388 388  * The details of "audio" settings, please refer to [[Audio>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HAudio]].
389 -* The details of ""camera" settings, please refer to [[camera>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HrtspwebA0camera]].
390 -* The details of ""mulit-link" settings, please refer to [[mulit-link>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HMulit-link]].
403 +* The details of "camera" settings, please refer to [[camera>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HrtspwebA0camera]].
404 +* The details of "mulit-link" settings, please refer to [[mulit-link>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HMulit-link]].
391 391  )))
392 392  
393 393  == Input device ==
... ... @@ -526,7 +526,7 @@
526 526  Only when object password is set,object password function could be used in object.
527 527  
528 528  (% style="text-align:center" %)
529 -[[image:安全设置 1.png||class="img-thumbnail"]]
543 +[[image:SecurityOverview.png]]
530 530  
531 531  == Objects password ==
532 532  
... ... @@ -537,14 +537,13 @@
537 537  
538 538  **Enable object password: **Check it to enable object security function. There are 12 levels corresponding to different passwords. The password of levels are set by the highest level.
539 539  
540 -1. **Passwords for levels:** It is used for set password for every level, it is composed of numbers and letters (case sensitive)within 8 digits.
541 -1. **Start level:** It is used for set initial level while this function is enabled.
542 -1. **Highest level**: It is used for set how many levels of password could be used.
543 -1. **Independent password:**
554 +* **Passwords for levels:** It is used for set password for every level, it is composed of numbers and letters (case sensitive)within 8 digits.
555 +* **Start level:** It is used for set initial level while this function is enabled.
556 +* **Highest level**: It is used for set how many levels of password could be used.
557 +* **Independent password:**
558 +** **Unchecked: **You should enter the corresponding level password when unlocking each level of object, and the higher level password could unlock the lower level object.
559 +** **Checked:** You could only type the corresponding level password when unlocking each level of object.
544 544  
545 -* **Unchecked: **You should enter the corresponding level password when unlocking each level of object, and the higher level password could unlock the lower level object.
546 -* **Checked:** You could only type the corresponding level password when unlocking each level of object.
547 -
548 548  ✎**Note:**
549 549  
550 550  * Object level password could be enabled in "Bit Switch", "Word Switch", "Function Switch", vCombination Switch", "Numeric Input", "Character Input", "Drop-down List" etc.
... ... @@ -566,6 +566,37 @@
566 566  1. **Password:** this password is used for unlocking screen, it is composed of numbers and letters (case sensitive) within 8 digits.
567 567  1. **Lock time:** It is used for setting time how long the screen will be locked if users do not operate, range: 1 to 240 minutes (integer).
568 568  
582 +== LAN Monitoring Security ==
583 +
584 +In the same Local Area Network, user can enter the IP of the HMI on the webpage to achieve LAN monitoring of the HMI
585 +
586 +The terminal access number of remote monitoring or LAN monitoring for each series of HMI models is limited, as following table shows:
587 +
588 +|=(% scope="row" style="width: 182px;" %)Model|=(% style="width: 178px;" %)System Version|=(% style="width: 153px;" %)LAN Monitoring|=(% style="width: 260px;" %)Remote Monitoring|=(% style="width: 241px;" %)Supported visits number
589 +|=(% style="width: 182px;" %)3000|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
590 +|=(% style="width: 182px;" %)3000i|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
591 +|=(% style="width: 182px;" %)3000ie|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
592 +|=(% style="width: 182px;" %)3000ig-O|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
593 +|=(% style="width: 182px;" %)3000ig/3000ig-C|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
594 +|=(% style="width: 182px;" %)8000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
595 +|=(% style="width: 182px;" %)8000ig|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
596 +|=(% style="width: 182px;" %)9000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
597 +
598 +After this function is enabled, user name and password need to be entered for LAN monitoring, which can avoid some uncontrollable security problems to a certain extent;
599 +
600 +{{info}}
601 +✎Note: This LAN Monitoring Security function is only supported by HMI V2.0 system and above.
602 +{{/info}}
603 +
604 +**Webpage monitoring**:
605 +
606 +After enable this function, when user input IP to access HMI, you need to enter the user name and password configured by HMI in the login interface first, and then you can access after verification(The login interface supports switching language between Chinese and English, the default is Chinese)
607 +
608 +(% style="text-align:center" %)
609 +[[image:LANSercuityloginpage.png]]
610 +
611 +If it is not configured this function in the project, it also can modify from the background interface
612 +
569 569  = Font pack =
570 570  
571 571  "Font pack" is for setting built-in font for HMI project, in this way, the text in some objects of the HMI could be displayed in the desired font.
... ... @@ -586,7 +586,7 @@
586 586  [[image:image-20220614173008-2.png]]
587 587  
588 588  (% start="5" %)
589 -1. Click [OK] to save settings.
633 +1. Click OK to save settings.
590 590  
591 591  **Result**
592 592  
DynamicScreensaver.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +2.7 KB
Content
LANSercuityloginpage.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +68.1 KB
Content
ProjectSettingOverview.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +26.1 KB
Content
SecurityOverview.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +20.0 KB
Content