Changes for page 03 Project Settings
Last modified by Hunter on 2024/06/11 15:58
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Karen - Content
-
... ... @@ -83,6 +83,19 @@ 83 83 ✎**Note**: When the Screensaver and the Screen Lock are enabled at the same time, the Screensaver can only be unlocked after unlocking the Screen Lock. 84 84 ))) 85 85 86 +== Enable Dynamic Screensaver == 87 + 88 +Same as Screensaver. Dynamic Screensaver provides the function is that prevent the HMI from displaying the same screen for a long time due to unattended operation. But Dynamic will be able to display animation. 89 + 90 +(% style="text-align:center" %) 91 +[[image:DynamicScreensaver.png]] 92 + 93 +**Enable dynamic screensaver:** If the screen is not operated within the set waiting time, it will automatically enter the set animation effect, and operating the screen again will exit the dynamic screensaver. 94 + 95 +**Standby Time(minutes): **When the screen is not operated, the waiting interval to enter the dynamic screensaver, ranges 1~~720. 96 + 97 +**Animation Type:** Types of effects currently provided are Raster, Blinds, and Bubble. 98 + 86 86 == Initial screen == 87 87 88 88 The "Initial screen" provides the interface to user to set initial screen. Initial screen means the first one displayed screen when HMI is powered on. ... ... @@ -118,8 +118,6 @@ 118 118 119 119 == Switch action == 120 120 121 -**Introduction** 122 - 123 123 The "Switch action" provides the action trigger settings. It is the effect timing of when the button executes the action. 124 124 125 125 (% style="text-align:center" %) ... ... @@ -349,7 +349,7 @@ 349 349 350 350 == Special expansion == 351 351 352 -"Special Expansion" is for extending audio play and camera input functions for special HMI models.363 +"Special expansion" is for extending audio play and camera input functions for special HMI models. 353 353 354 354 (% style="text-align:center" %) 355 355 [[image:05.Project Settings_html_784d40de9b3e3bda.png||height="109" width="543"]] ... ... @@ -498,7 +498,8 @@ 498 498 * DataLogFile is data log record. It can only download files, but cannot upload files. 499 499 * RecipeFile is recipe. It can only download files, but cannot upload files. 500 500 * UserMgrFile is operation record. It can only download files, but cannot upload files. 501 -* Sdcard is the mounting directory of SD card. There will be the subdirectory of S1 to Sn when connected SD card. It can upload and download. 512 +* Sdcard is the mounting directory of SD card. There will be the subdirectory of S1, S2, S3, etc. when connected SD card. It can upload and download. 513 +* Udisk is the mounting directory of USB flash drive. There will be the subdirectory of U1, U2, U3, etc. when connected USB flash drive. It can upload and download. 502 502 503 503 (% class="box infomessage" %) 504 504 ((( ... ... @@ -526,7 +526,7 @@ 526 526 Only when object password is set,object password function could be used in object. 527 527 528 528 (% style="text-align:center" %) 529 -[[image: 安全设置 1.png||class="img-thumbnail"]]541 +[[image:SecurityOverview.png]] 530 530 531 531 == Objects password == 532 532 ... ... @@ -565,6 +565,47 @@ 565 565 1. **Password:** this password is used for unlocking screen, it is composed of numbers and letters (case sensitive) within 8 digits. 566 566 1. **Lock time:** It is used for setting time how long the screen will be locked if users do not operate, range: 1 to 240 minutes (integer). 567 567 580 +== LAN Monitoring Security == 581 + 582 +(% style="text-align:center" %) 583 +[[image:SecurityOption.png]] 584 + 585 +In the same Local Area Network, user can enter the IP of the HMI on the webpage to achieve LAN monitoring of the HMI 586 + 587 +The terminal access number of remote monitoring or LAN monitoring for each series of HMI models is limited, as following table shows: 588 + 589 +|=(% scope="row" style="width: 182px;" %)Model|=(% style="width: 178px;" %)System Version|=(% style="width: 153px;" %)LAN Monitoring|=(% style="width: 260px;" %)Remote Monitoring|=(% style="width: 241px;" %)Supported visits number 590 +|=(% style="width: 182px;" %)3000|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1 591 +|=(% style="width: 182px;" %)3000i|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1 592 +|=(% style="width: 182px;" %)3000ie|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1 593 +|=(% style="width: 182px;" %)3000ig-O|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1 594 +|=(% style="width: 182px;" %)3000ig/3000ig-C|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4 595 +|=(% style="width: 182px;" %)8000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4 596 +|=(% style="width: 182px;" %)8000ig|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4 597 +|=(% style="width: 182px;" %)9000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4 598 + 599 +After this function is enabled, user name and password need to be entered for LAN monitoring, which can avoid some uncontrollable security problems to a certain extent; 600 + 601 +{{info}} 602 +✎Note: This LAN Monitoring Security function is only supported by HMI V2.0 system and above. 603 +{{/info}} 604 + 605 +**Webpage monitoring**: 606 + 607 +After enable this function, when user input IP to access HMI, you need to enter the user name and password configured by HMI in the login interface first, and then you can access after verification(The login interface supports switching language between Chinese and English, the default is Chinese) 608 + 609 +(% style="text-align:center" %) 610 +[[image:LANSercuityloginpage.png]] 611 + 612 +If it is not configured this function in the project, it also can modify from the background interface. 613 + 614 +System->Extend 615 + 616 +(% style="text-align:center" %) 617 +[[image:LANBackground.png]] 618 + 619 + 620 + 568 568 = Font pack = 569 569 570 570 "Font pack" is for setting built-in font for HMI project, in this way, the text in some objects of the HMI could be displayed in the desired font.
- DynamicScreensaver.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.7 KB - Content
- LANBackground.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +652.7 KB - Content
- LANSercuityloginpage.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +68.1 KB - Content
- SecurityOption.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.0 KB - Content
- SecurityOverview.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.0 KB - Content