Changes for page 03 Project Settings

Last modified by Hunter on 2024/06/11 15:58

From version 17.1
edited by Hunter
on 2023/01/07 16:18
Change comment: There is no comment for this version
To version 26.1
edited by Karen
on 2023/05/26 16:45
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Karen
Content
... ... @@ -83,19 +83,18 @@
83 83  ✎**Note**: When the Screensaver and the Screen Lock are enabled at the same time, the Screensaver can only be unlocked after unlocking the Screen Lock.
84 84  )))
85 85  
86 -(% class="wikigeneratedid" %)
87 87  == Enable Dynamic Screensaver ==
88 88  
89 -Same to Screensaver. Dynamic Screensaver provides the function is that prevent the HMI from displaying the same screen for a long time due to unattended operation. But the Dynamic will be able to display animation.
88 +Same as Screensaver. Dynamic Screensaver provides the function is that prevent the HMI from displaying the same screen for a long time due to unattended operation. But Dynamic will be able to display animation.
90 90  
91 91  (% style="text-align:center" %)
92 92  [[image:DynamicScreensaver.png]]
93 93  
94 -**Enable dynamic screensaver:** If the screen is not operated within the set waiting time, it will automatically enter the set animation effect, and operating the screen again will exit the dynamic screensaver;
93 +**Enable dynamic screensaver:** If the screen is not operated within the set waiting time, it will automatically enter the set animation effect, and operating the screen again will exit the dynamic screensaver.
95 95  
96 -**Standby Time(minutes): **When the screen is not operated, the waiting interval to enter the dynamic screensaver, ranges 1~~720;
95 +**Standby Time(minutes): **When the screen is not operated, the waiting interval to enter the dynamic screensaver, ranges 1~~720.
97 97  
98 -**Animation Type:** Types of effects currently provided are Raster, Blinds, Bubble.
97 +**Animation Type:** Types of effects currently provided are Raster, Blinds, and Bubble.
99 99  
100 100  == Initial screen ==
101 101  
... ... @@ -132,8 +132,6 @@
132 132  
133 133  == Switch action ==
134 134  
135 -**Introduction**
136 -
137 137  The "Switch action" provides the action trigger settings. It is the effect timing of when the button executes the action.
138 138  
139 139  (% style="text-align:center" %)
... ... @@ -363,7 +363,7 @@
363 363  
364 364  == Special expansion ==
365 365  
366 -"Special Expansion" is for extending audio play and camera input functions for special HMI models.
363 +"Special expansion" is for extending audio play and camera input functions for special HMI models.
367 367  
368 368  (% style="text-align:center" %)
369 369  [[image:05.Project Settings_html_784d40de9b3e3bda.png||height="109" width="543"]]
... ... @@ -512,7 +512,8 @@
512 512  * DataLogFile is data log record. It can only download files, but cannot upload files.
513 513  * RecipeFile is recipe. It can only download files, but cannot upload files.
514 514  * UserMgrFile is operation record. It can only download files, but cannot upload files.
515 -* Sdcard is the mounting directory of SD card. There will be the subdirectory of S1 to Sn when connected SD card. It can upload and download.
512 +* Sdcard is the mounting directory of SD card. There will be the subdirectory of S1, S2, S3, etc. when connected SD card. It can upload and download.
513 +* Udisk is the mounting directory of USB flash drive. There will be the subdirectory of U1, U2, U3, etc. when connected USB flash drive. It can upload and download.
516 516  
517 517  (% class="box infomessage" %)
518 518  (((
... ... @@ -540,20 +540,20 @@
540 540  Only when object password is set,object password function could be used in object.
541 541  
542 542  (% style="text-align:center" %)
543 -[[image:安全设置 1.png||class="img-thumbnail"]]
541 +[[image:SecurityOverview.png]]
544 544  
545 545  == Objects password ==
546 546  
547 -You should enter password to access the protected object. This could avoid some misoperation on object. There are 12 levels in object password setting, and each level corresponds to each password.
545 +Users should enter password to access the protected object. This could avoid some misoperation on object. There are 12 levels in object password setting, and each level corresponds to each password.
548 548  
549 549  (% style="text-align:center" %)
550 550  [[image:05.Project Settings_html_4835fff86888a26b.png||height="238" width="502"]]
551 551  
552 -**Enable object password: **Check it to enable object security function. There are 12 levels corresponding to different passwords. The password of levels are set by the highest level.
550 +**Enable object password: **Check it to enable object security function. There are 12 levels corresponding to different passwords. The password of levels is set by the highest level.
553 553  
554 -* **Passwords for levels:** It is used for set password for every level, it is composed of numbers and letters (case sensitive)within 8 digits.
555 -* **Start level:** It is used for set initial level while this function is enabled.
556 -* **Highest level**: It is used for set how many levels of password could be used.
552 +* **Passwords for levels:** It is used to set password for every level, it is composed of numbers and letters (case sensitive)within 8 digits.
553 +* **Start level:** It is used to set initial level while this function is enabled.
554 +* **Highest level**: It is used to set how many levels of password could be used.
557 557  * **Independent password:**
558 558  ** **Unchecked: **You should enter the corresponding level password when unlocking each level of object, and the higher level password could unlock the lower level object.
559 559  ** **Checked:** You could only type the corresponding level password when unlocking each level of object.
... ... @@ -560,13 +560,13 @@
560 560  
561 561  ✎**Note:**
562 562  
563 -* Object level password could be enabled in "Bit Switch", "Word Switch", "Function Switch", vCombination Switch", "Numeric Input", "Character Input", "Drop-down List" etc.
561 +* Object level password could be enabled in "Bit Switch", "Word Switch", "Function Switch", combination "Switch", "Numeric Input", "Character Input", "Drop-down List" etc.
564 564  
565 565  (% style="text-align:center" %)
566 566  [[image:安全设置 2.png||class="img-thumbnail"]]
567 567  
568 -* The configured password could not be empty, otherwise when users close the configuration screen ,there will be an error: "please set password for level".
569 -* If configured object password level is higher than highest password setting in Project Settingss, there will be an error note during compiling: "the security level of this object is out of range!" .Users need to set password level again to solve the problem.
566 +* The configured password could not be empty, otherwise, when users close the configuration screen, there will be an error: "Please set password for level".
567 +* If configured object password level is higher than highest password setting in Project Settingss, there will be an error note during compiling: "The security level of this object is out of range!" . Users need to set password level again to solve the problem.
570 570  
571 571  == Screen Lock ==
572 572  
... ... @@ -579,6 +579,47 @@
579 579  1. **Password:** this password is used for unlocking screen, it is composed of numbers and letters (case sensitive) within 8 digits.
580 580  1. **Lock time:** It is used for setting time how long the screen will be locked if users do not operate, range: 1 to 240 minutes (integer).
581 581  
580 +== LAN Monitoring Security ==
581 +
582 +(% style="text-align:center" %)
583 +[[image:SecurityOption.png]]
584 +
585 +In the same Local Area Network, user can enter the IP of the HMI on the webpage to achieve LAN monitoring of the HMI
586 +
587 +The terminal access number of remote monitoring or LAN monitoring for each series of HMI models is limited, as following table shows:
588 +
589 +|=(% scope="row" style="width: 182px;" %)Model|=(% style="width: 178px;" %)System Version|=(% style="width: 153px;" %)LAN Monitoring|=(% style="width: 260px;" %)Remote Monitoring|=(% style="width: 241px;" %)Supported visits number
590 +|=(% style="width: 182px;" %)3000|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
591 +|=(% style="width: 182px;" %)3000i|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
592 +|=(% style="width: 182px;" %)3000ie|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
593 +|=(% style="width: 182px;" %)3000ig-O|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
594 +|=(% style="width: 182px;" %)3000ig/3000ig-C|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
595 +|=(% style="width: 182px;" %)8000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
596 +|=(% style="width: 182px;" %)8000ig|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
597 +|=(% style="width: 182px;" %)9000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
598 +
599 +After this function is enabled, user name and password need to be entered for LAN monitoring, which can avoid some uncontrollable security problems to a certain extent;
600 +
601 +{{info}}
602 +✎Note: This LAN Monitoring Security function is only supported by HMI V2.0 system and above.
603 +{{/info}}
604 +
605 +**Webpage monitoring**:
606 +
607 +After enable this function, when user input IP to access HMI, you need to enter the user name and password configured by HMI in the login interface first, and then you can access after verification(The login interface supports switching language between Chinese and English, the default is Chinese)
608 +
609 +(% style="text-align:center" %)
610 +[[image:LANSercuityloginpage.png]]
611 +
612 +If it is not configured this function in the project, it also can modify from the background interface.
613 +
614 +System->Extend
615 +
616 +(% style="text-align:center" %)
617 +[[image:LANBackground.png]]
618 +
619 +
620 +
582 582  = Font pack =
583 583  
584 584  "Font pack" is for setting built-in font for HMI project, in this way, the text in some objects of the HMI could be displayed in the desired font.
LANBackground.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +652.7 KB
Content
LANSercuityloginpage.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +68.1 KB
Content
SecurityOption.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +2.0 KB
Content
SecurityOverview.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +20.0 KB
Content