3 3  The following steps will show how to change HMI project communication settings.
4 4  
5 -**Operating procedure**
5 +**OperatingProcedure**
6 6  
7 -Click "Project""Communication" to open setting window.
7 +1. Click "Project"->"Communication" to open setting window.
8 8  
9 9  (% style="text-align:center" %)
10 10  [[image:image-20220614172512-1.png]]
11 11  
12 -Click "Setting" to open "Communication device" window.
12 +(% start="2" %)
13 +1. Click "Setting" to open "Communication device" window.
13 13  
14 14  (% style="text-align:center" %)
15 15  [[image:image-20220614172519-2.png]]
16 16  
17 -Select connection way, device protocol.
18 +(% start="3" %)
19 +1. Select connection way, device protocol.
20 +1. Click "Settings" to change communication parameters, COM is for serial connection, Device IP is for Ethernet connection.
18 18  
19 -Click "Settings" to change communication parameters, COM is for serial connection, Device IP is for Ethernet connection.
20 -
21 21  (% style="text-align:center" %)
22 22  [[image:image-20220614172524-3.png]]
23 23  
24 -Click "OK" to save changes.
25 +(% start="5" %)
26 +1. Click "OK" to save changes.
25 25  
26 26  **Result**
27 27  
28 28  HMI communication is changed.
29 29  
30 -= **Project settings** =
32 += **Project Settings** =
31 31  
32 32  This place is mainly available for parameters settings, like model selection, storage method or some others parameters.
33 33  
... ... @@ -40,12 +40,12 @@
40 40  (% style="text-align:center" %)
41 41  [[image:05.Project Settings_html_fc73c5d892676da1.png||height="252" width="212" class="img-thumbnail"]]
42 42  
43 -== Project settings ==
45 +== **{{id name="_Toc7072"/}}Project Settings** ==
44 44  
45 45  (% style="text-align:center" %)
46 -[[image:ProjectSettingOverview.png]]
48 +[[image:工程设置 1.png||class="img-thumbnail"]]
47 47  
48 -== HMI model ==
50 +== **{{id name="_Toc17881"/}}HMI model** ==
49 49  
50 50  "HMI Model" provides the function of modifying the HMI model to help the user switch the project to suit different models. Because different models have different resolution, when user trying to change this option, PIStudio will ask you whether want to generate a backup of older version project if you enable the option project backup.
51 51  
... ... @@ -52,7 +52,7 @@
52 52  (% style="text-align:center" %)
53 53  [[image:05.Project Settings_html_768ecc1e77aaf98.png||height="134" width="538"]]
54 54  
55 -**Operating procedure**
57 +**Operating Procedure**
56 56  
57 57  1. Open "Project Settings" windows.
58 58  1. Select HMI Series.
... ... @@ -60,7 +60,7 @@
60 60  1. Check the box of "Project backup" according to the needful.
61 61  1. Click "OK" to save settings and exit window.
62 62  
63 -== Enable screensaver ==
65 +== **{{id name="_Toc26701"/}}Enable screensaver** ==
64 64  
65 65  Screensaver provides the function is that prevent the HMI from displaying the same screen for a long time due to unattended operation. After a certain interval, the HMI will jump into a screensaver screen.
66 66  
... ... @@ -67,10 +67,9 @@
67 67  (% style="text-align:center" %)
68 68  [[image:05.Project Settings_html_9d248cebcde9d831.png||height="51" width="539"]]
69 69  
70 -**Standby Time:** The interval time to enter the screensaver Range 0~~43200 seconds.
72 +1. **Standby Time:** The interval time to enter the screensaver Range 0~~43200 seconds.
73 +1. **Screensave No.:** Set which screen will jump into when screensaver is executed.
71 71  
72 -**Screensave No.:** Set which screen will jump into when screensaver is executed.
73 -
74 74  **Operating Procedure**
75 75  
76 76  1. Open "Project Settings" windows.
... ... @@ -78,39 +78,22 @@
78 78  1. Modify Standby Time according to your need.
79 79  1. Select screensaver screen in drop-down list, use screen No.1 for example.
80 80  
81 -(% class="box infomessage" %)
82 -(((
83 83  ✎**Note**: When the Screensaver and the Screen Lock are enabled at the same time, the Screensaver can only be unlocked after unlocking the Screen Lock.
84 -)))
85 85  
86 -(% class="wikigeneratedid" %)
87 -== Enable Dynamic Screensaver ==
84 +== **Initial screen** ==
88 88  
89 -Same to Screensaver. Dynamic Screensaver provides the function is that prevent the HMI from displaying the same screen for a long time due to unattended operation. But the Dynamic will be able to display animation.
86 +The [Initial screen] provides the interface to user to set initial screen. Initial screen means the first one displayed screen when HMI is powered on.
90 90  
91 91  (% style="text-align:center" %)
92 -[[image:DynamicScreensaver.png]]
93 -
94 -**Enable dynamic screensaver:** If the screen is not operated within the set waiting time, it will automatically enter the set animation effect, and operating the screen again will exit the dynamic screensaver;
95 -
96 -**Standby Time(minutes): **When the screen is not operated, the waiting interval to enter the dynamic screensaver, ranges 1~~720;
97 -
98 -**Animation Type:** Types of effects currently provided are Raster, Blinds, Bubble.
99 -
100 -== Initial screen ==
101 -
102 -The "Initial screen" provides the interface to user to set initial screen. Initial screen means the first one displayed screen when HMI is powered on.
103 -
104 -(% style="text-align:center" %)
105 105  [[image:05.Project Settings_html_562a3a4e9d3ef218.png||height="43" width="259"]]
106 106  
107 107  **Operating Procedure**
108 108  
109 -1. Open "Project Settings" windows.
93 +1. Open [Project Settings] windows.
110 110  1. Select initial screen in drop-list, use screen 2 as an example.
111 -1. Click "OK" button to save setting and exit windows.
95 +1. Click [OK] button to save setting and exit windows.
112 112  
113 -== Operation record ==
97 +== **{{id name="_Toc29634"/}}{{id name="_Toc479868165"/}}Operation record** ==
114 114  
115 115  This setting needs to be used in conjunction with "User Permission" function, which is valid only when "User Permission" function is turned on. The detailed information of "User Permission", "Operation Record" is mainly recording the operation for the current user after user login.
116 116  
... ... @@ -117,7 +117,7 @@
117 117  (% style="text-align:center" %)
118 118  [[image:05.Project Settings_html_ff3f128cf0a734a2.png||height="44" width="272"]]
119 119  
120 -== Byte order ==
104 +== **{{id name="_Toc13922"/}}Byte order** ==
121 121  
122 122  Floating point is one of the commonly used data formats, and it is two-byte order mode. PIStudio provides the interface in "Project Settingss" for setting the byte order.The default mode is Little-endian. This function has no effect on the HSW addresses.
123 123  
... ... @@ -130,11 +130,11 @@
130 130  1. Select "Little-endian" or "Big-endian" mode.
131 131  1. Click "OK" button to save setting and exit window.
132 132  
133 -== Switch action ==
117 +== **{{id name="_Toc18233"/}}{{id name="_Toc479868167"/}}Switch action** ==
134 134  
135 135  **Introduction**
136 136  
137 -The "Switch action" provides the action trigger settings. It is the effect timing of when the button executes the action.
121 +The [Switch action] provides the action trigger settings. It is the effect timing of when the button executes the action.
138 138  
139 139  (% style="text-align:center" %)
140 140  [[image:05.Project Settings_html_59a2f3cd00554dc2.png||height="47" width="272"]]
... ... @@ -148,7 +148,7 @@
148 148  1. Select switch action mode.
149 149  1. Click "OK" button to save setting and exit window.
150 150  
151 -== Backlight ==
135 +== **{{id name="_Toc479868168"/}}{{id name="_Toc13186"/}}Backlight** ==
152 152  
153 153  "Backlight" is for controlling LCD, after designated time of inactivity, HMI LCD will turn OFF automatically, but this setting will be invalid when alarm is ON. The default setting is never turning OFF LCD.
154 154  
... ... @@ -161,7 +161,7 @@
161 161  1. Select duration time.
162 162  1. Click "OK" button to save setting and exit window.
163 163  
164 -== Data record storage ==
148 +== **{{id name="_Toc479868169"/}}{{id name="_Toc22376"/}}{{id name="_Data_Record_Storage"/}}Data record storage** ==
165 165  
166 166  This setting needs to be used in conjunction with [Data Record] function, which is valid only when [Data Record] function is effective. The data record files will be saved in Flash.
167 167  
... ... @@ -174,7 +174,7 @@
174 174  1. Select storage path.
175 175  1. Click "OK" button to save setting and exit window.
176 176  
177 -== Designer Password ==
161 +== **{{id name="_Toc479868173"/}}{{id name="_Toc3744"/}}Designer Password** ==
178 178  
179 179  "Designer Password" provides the encryption functions of the HMI project, including upload and decompile operations. Also it affects the user permissions, installments and other functions.
180 180  
... ... @@ -189,7 +189,7 @@
189 189  1. Enter password
190 190  1. Click "OK" button to save setting and exit windows
191 191  
192 -== Use screen ID address ==
176 +== **{{id name="_Toc479868172"/}}Use Screen ID Address** ==
193 193  
194 194  "Use Screen ID address" provides the function of controlling HMI screens by specific address' value. The address could be set by the user.
195 195  
... ... @@ -211,7 +211,7 @@
211 211  * If HDW0=1, HMI displays Screen No.1.
212 212  * …
213 213  
214 -= HMI IP settings =
198 += **{{id name="_Toc5327"/}}{{id name="_Toc479868175"/}}HMI IP settings** =
215 215  
216 216  This is for setting HMI static IP (HMI also could support DHCP). When enable DHCP mode, the setting is invalid.
217 217  
... ... @@ -220,8 +220,6 @@
220 220  (% style="text-align:center" %)
221 221  [[image:HMI IP 1.png]]
222 222  
223 -(% class="box infomessage" %)
224 -(((
225 225  **✎Note:**
226 226  
227 227  * HMI backstage screen could select Wi-fi or Ethernet mode.
... ... @@ -228,7 +228,6 @@
228 228  * Wi-fi and Ethernet mode only can be switched by manual.
229 229  * IP setting function only can be enabled when HMI is ethernet mode.
230 230  * It is only supported by 8000 series.
231 -)))
232 232  
233 233  **Operating Procedure**
234 234  
... ... @@ -236,11 +236,11 @@
236 236  1. Open "HMI IP" sub-window.
237 237  1. Check "HMI IP".
238 238  1. Enter IP.
239 -1. Click "OK" button to save setting and exit windows.
220 +1. {{id name="_Toc479868176"/}}{{id name="_Toc8172"/}}Click "OK" button to save setting and exit windows.
240 240  
241 -== Remote access password ==
222 +== **Remote access password** ==
242 242  
243 -"Remote Access Password" is for PI8000/PI9000 series HMI, the password is for remote function, when users use Smart APP on mobile or weconcloud website on PC, which could access HMI screen remotely, the APP or website will require this password.
224 +[Remote Access Password] is for PI8000/PI9000 series HMI, the password is for remote function, when users use Smart APP on mobile or weconcloud website on PC, which could access HMI screen remotely, the APP or website will require this password.
244 244  
245 245  (% style="text-align:center" %)
246 246  [[image:05.Project Settings_html_3edf539b482a57a8.png||height="51" width="412"]]
... ... @@ -248,11 +248,11 @@
248 248  **Operating Procedure**
249 249  
250 250  1. Open "Project Settings" windows;
251 -1. Open "HMI IP" sub-windows;
232 +1. Open "HMI IP] sub-windows;
252 252  1. Enter password;
253 253  1. Click "OK" button to save setting and exit windows;
254 254  
255 -== Server of HMI remote access ==
236 +== **Server of HMI Remote Access** ==
256 256  
257 257  "Server of HMI remote access" is for PI8000/PI9000 series with -R model HMIs, when users use Smart APP on mobile or weconcloud website on PC, there are two options from selection available for speed up access. Server 1 is for Chinese users, Server 2 is for aboard users.
258 258  
... ... @@ -259,7 +259,7 @@
259 259  (% style="text-align:center" %)
260 260  [[image:05.Project Settings_html_e877533ce894d9f7.png||height="64" width="475"]]
261 261  
262 -= **Installment** =
243 += **{{id name="_Toc30218"/}}Installment** =
263 263  
264 264  "Installment" meets the needs of the designer or equipment manufacturer to provide the trial period to the end customer.
265 265  
... ... @@ -268,18 +268,19 @@
268 268  (% style="text-align:center" %)
269 269  [[image:分期付款 1.png||class="img-thumbnail"]]
270 270  
271 -== Static mode ==
252 +== **Static mode** ==
272 272  
254 +
273 273  The expiry time and key of each period could not be empty, and they need to be configured in advance. And the expiry time of the latter period need to be later than the expiry of the previous period.
274 274  
275 275  1. **Use admin key: **It can be used for unlock all expirations,in addition to each period key.If users select [use admin key] function,once users enter the admin key when HMI expires,the installment payment function will be disabled.
276 -1. **Admin: **Password (Key) for "use admin key";
258 +1. **Admin: **Password (Key) for [use admin key];
277 277  1. **Max periods: **The period of static installment payment range is 0-12.When the maximum number of period is 0,it means that the instalment payment function is disabled;
278 278  1. **Begin Period: **Set the installment payment to start from the first period, the range is 1-13;
279 279  1. **List: **Configure a list based on [Maximum Periods] and [Begin Period],where user can configure the password and expiration time for each period.
280 280  1. **Use admin key: **It is independent password, and all the expired password can be unlocked by it. If you check it, the installment function would be disabled after you input the admin key. The key can be a combination of "A~~z", "a~~z" and "0~~9"(case-sensitive).
281 281  
282 -== Dynamic mode ==
264 +== **Dynamic mode** ==
283 283  
284 284  To enable the function of the installment payment, you must set up the following parameters
285 285  
... ... @@ -318,8 +318,6 @@
318 318  1. **Clear Bit: **Clear bit when user enters the right installment password.
319 319  1. **Upcoming Alert:** HMI show the installment alert before expire date (before 1,3 or 5 days)
320 320  
321 -(% class="box infomessage" %)
322 -(((
323 323  **✎Note:**
324 324  
325 325  1. The screen of setting intallment and enter password is the built-in sub-screen, and couldn't bue modified.
... ... @@ -329,19 +329,18 @@
329 329  1. The password cannot exceed 6 characters. The password can be composed of three modes: numbers, letters, and Chinese characters. Chinese characters contain only three characters and letters are case sensitive. The three key modes can be mixed.
330 330  1. Each key corresponds to a admin key. After entering the admin key in the installment password interface pop up by HMI, the installment function will be turned off, that is, the installment password interface will no longer pop up. So you should not use the admin key at will, or open up the admin key to others.
331 331  1. In the dynamic mode of installment payments, select "Enable valid period for password", then the "valid days" must be the same day as the current time of HMI.  If the time is not the same day, then the generated password is invalid.
332 -)))
333 333  
334 -== Password tool ==
313 +== **Password tool** ==
335 335  
336 336  (% class="wikigeneratedid" id="HPasswordtool" %)
337 -For the detail, please click [["Password tool">>https://docs.we-con.com.cn/bin/view/PIStudio/14.Tools/#HPasswordtool]].
316 +For the detail, please click [["Password tool">>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/14.Tools/#HPasswordtool]].
338 338  
339 -= **Extend** =
318 += **{{id name="_Toc734"/}}Extend** =
340 340  
341 341  (% style="text-align:center" %)
342 342  [[image:扩展 1.png||class="img-thumbnail"]]
343 343  
344 -== Into setup ==
323 +== **{{id name="_Toc31631"/}}Into Setup** ==
345 345  
346 346  It provides entrance ways of the backstage interface.
347 347  
... ... @@ -348,27 +348,31 @@
348 348  (% style="text-align:center" %)
349 349  [[image:05.Project Settings_html_53acbd1d326cab4f.png||height="126" width="471"]]
350 350  
351 -* **Startup: **it means after the HMI starts and displays the LOGO, press and holding the upper-right corner within the set time is able to enter the background interface. If the time is exceeded the setting time, the long press would be invalid.
352 -** For example, the Time is 5 seconds, then within 5 seconds after the LOGO is displayed, long press the upper-right corner can normally enter the screen. But if more than 5 seconds, long press will not be able to access.
353 -* **Running: **it means when HMI running the project, press and holding the upper-right corner over certain time, it would enter the backstage interface.
354 -** For example, the Time is 5 seconds, then long press the upper-right corner lasting over 5 seconds, it would able to access.
330 +1. **Startup: **it means after the HMI starts and displays the LOGO, press and holding the upper-right corner within the set time is able to enter the background interface. If the time is exceeded the setting time, the long press would be invalid.
355 355  
356 -**Operating procedure**
332 +* For example, the Time is 5 seconds, then within 5 seconds after the LOGO is displayed, long press the upper-right corner can normally enter the screen. But if more than 5 seconds, long press will not be able to access.
357 357  
334 +(% start="2" %)
335 +1. **Running: **it means when HMI running the project, press and holding the upper-right corner over certain time, it would enter the backstage interface.
336 +
337 +* For example, the Time is 5 seconds, then long press the upper-right corner lasting over 5 seconds, it would able to access.
338 +
339 +**Operating Procedure**
340 +
358 358  1. Open "Project Settings" windows.
359 359  1. Open "Extend" sub-windows.
360 -1. Select "Startup" or "Running".
343 +1. Select "Startup" or [Running.
361 361  1. Set "Time".
362 362  1. Set "Password" if you require the password when entering the backstage interface.
363 363  
364 -== Special expansion ==
347 +== **{{id name="_Toc3554"/}}Special Expansion** ==
365 365  
366 -"Special Expansion" is for extending audio play and camera input functions for special HMI models.
349 +[Special Expansion] is for extending audio play and camera input functions for special HMI models.
367 367  
368 368  (% style="text-align:center" %)
369 369  [[image:05.Project Settings_html_784d40de9b3e3bda.png||height="109" width="543"]]
370 370  
371 -**Operating procedure**
354 +**Operating Procedure**
372 372  
373 373  1. Open "Project Settings" windows.
374 374  1. Open "Extend" sub-windows.
... ... @@ -382,7 +382,7 @@
382 382  (% style="text-align:center" %)
383 383  [[image:05.Project Settings_html_baff180660df10b7.png||height="43" width="388" class="img-thumbnail"]]
384 384  
385 -**Operating procedure of Multi-link**
368 +**Operating Procedure of Multi-link**
386 386  
387 387  1. Open "Project Settings" windows.
388 388  1. Open "Extend" sub-windows.
... ... @@ -394,17 +394,14 @@
394 394  
395 395  One HMI can display in multiple screens, through Master-Slave connection.
396 396  
397 -(% class="box infomessage" %)
398 -(((
399 399  ✎**Note:**
400 400  
401 401  * These all three functions are not available for all HMIs, only special HMI models could support them.
402 -* The details of "audio" settings, please refer to [[Audio>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HAudio]].
403 -* The details of "camera" settings, please refer to [[camera>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HrtspwebA0camera]].
404 -* The details of "mulit-link" settings, please refer to [[mulit-link>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HMulit-link]].
405 -)))
383 +* The details of "audio" settings, please refer to [[Audio>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/11.Advanced%20Function/#HAudio]].
384 +* The details of ""camera" settings, please refer to [[camera>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/11.Advanced%20Function/#HAudio]].
385 +* The details of ""mulit-link" settings, please refer to [[mulit-link>>http://docs.we-con.com.cn/wiki/pistudio/view/Helps/11.Advanced%20Function/#HAudio]].
406 406  
407 -== Input device ==
387 +== **Input Device** ==
408 408  
409 409  It is used for enable input devices, like keyboard and mouse.
410 410  
... ... @@ -422,7 +422,7 @@
422 422  
423 423  The arrow will be display in screen when HMI is running, and keyboard could be used to enter code and control arrow.
424 424  
425 -== Lab ==
405 +== **Lab** ==
426 426  
427 427  Lab is used for enable experimental function.
428 428  
... ... @@ -433,7 +433,7 @@
433 433  1. **Xml Optimization**: Improve xml operation efficiency and speed up screen compilation.
434 434  1. **Enable Lua Debugging**: Control the Lua debugging window whether opened or not when using the Lua script.
435 435  
436 -== Vector ==
416 +== **Vector** ==
437 437  
438 438  It is the function deal with the display issue.
439 439  
... ... @@ -450,91 +450,8 @@
450 450  1. Check "Vector Font" or "Vector Image".
451 451  1. Click "OK" to save and exist.
452 452  
453 -== Udisk pop-up ==
433 += **{{id name="_Toc29782"/}}Security** =
454 454  
455 -(% style="text-align:center" %)
456 -[[image:image-20220808091210-1.jpeg]]
457 -
458 -There are two methods to enable Udisk pop-up function.
459 -
460 -* Click "Project setting" → "Udick pop-up", the built-in screen 5004 would pop up after inserting the Udisk.
461 -* Udisk pop-up flag file: Create a blank text file in the root directory of the U disk, named "download.dat", and the screen could pop up after inserting the U disk.
462 -
463 -(% class="box infomessage" %)
464 -(((
465 -**✎Note:** The Udick pop-up function is only supported by the formware of  PIStudio V8.2.29_D20220302 and above. For the version of PIStudio, please refer to "About".
466 -)))
467 -
468 -**Udisk pop-up interface**
469 -
470 -The interface of the Udisk pop-up is 5004 built-in screen. If the pop-up interface is not operated within 10s of the pop-up, it will be closed automatically.
471 -
472 -(% style="text-align:center" %)
473 -[[image:image-20220808093055-3.jpeg||height="212" width="307"]]
474 -
475 -1. **Project: **Enter the download project interface.
476 -1. **Firmware: **Enter the download project interface.
477 -1. **Backstage: **Enter the backstage directly.
478 -1. **Exit: **Close the pop up screen.
479 -
480 -== FTP server ==
481 -
482 -(% style="text-align:center" %)
483 -[[image:image-20220808093816-5.png||class="img-thumbnail"]]
484 -
485 -**Enable method: **"Project parameter" → "Extend" → check "FTP service".
486 -
487 -**Usage:**
488 -
489 -* Enter "ftp:~/~/ + the IP address of the HMI" in the folder address bar.
490 -
491 -(% style="text-align:center" %)
492 -[[image:image-20220808094729-7.png||height="429" width="909" class="img-thumbnail"]]
493 -
494 -* You can also enter “ftp:~/~/ftpuser:000000@192.168.39.242” to access the interface directly (with a username and password).
495 -
496 -(% style="text-align:center" %)
497 -[[image:image-20220808100330-10.jpeg||class="img-thumbnail"]]
498 -
499 -* If the ftp service is enabled, it will prompt for a username and password, and if not, it will prompt that the connection to the server cannot be established.
500 -
501 -(% style="text-align:center" %)
502 -[[image:image-20220808100223-9.jpeg]]
503 -
504 -* Enter the username and password as configured in the project.
505 -
506 -(% style="text-align:center" %)
507 -[[image:image-20220808100720-11.jpeg||class="img-thumbnail"]]
508 -
509 -**Description of folder and permission**
510 -
511 -* AlarmFile is alarm record. It can only download files, but cannot upload files.
512 -* DataLogFile is data log record. It can only download files, but cannot upload files.
513 -* RecipeFile is recipe. It can only download files, but cannot upload files.
514 -* UserMgrFile is operation record. It can only download files, but cannot upload files.
515 -* Sdcard is the mounting directory of SD card. There will be the subdirectory of S1 to Sn when connected SD card. It can upload and download.
516 -
517 -(% class="box infomessage" %)
518 -(((
519 -**✎Note:** For Udisk and SD card, it is recommended to use NTFS format.
520 -)))
521 -
522 -Maximum number of connections: up to 5 clients can be supported to access the interface at the same time.
523 -
524 -Password modification: Use the changePsd function in the lua function ftpserver library to modify password.
525 -
526 -* Prototype: ftpserver.changePsd(oldPsd,newPsd)
527 -* Function: change the login password of ftpserver
528 -* Parameters:
529 -** oldPsd(string) old password
530 -** newPsd(string) new password.
531 -* Format: only letters, numbers and underscores are allowed, and the length must be 6 to 8 digits.
532 -* Returns.
533 -** Success: true
534 -** Failure: nil,err
535 -
536 -= **Security** =
537 -
538 538  Security means objects and screen security, but this function is only available in 3000i series and HMI+ series or above.
539 539  
540 540  Only when object password is set,object password function could be used in object.
... ... @@ -542,7 +542,7 @@
542 542  (% style="text-align:center" %)
543 543  [[image:安全设置 1.png||class="img-thumbnail"]]
544 544  
545 -== Objects password ==
442 +== **{{id name="_Toc16190"/}}Objects password** ==
546 546  
547 547  You should enter password to access the protected object. This could avoid some misoperation on object. There are 12 levels in object password setting, and each level corresponds to each password.
548 548  
... ... @@ -549,15 +549,16 @@
549 549  (% style="text-align:center" %)
550 550  [[image:05.Project Settings_html_4835fff86888a26b.png||height="238" width="502"]]
551 551  
552 -**Enable object password: **Check it to enable object security function. There are 12 levels corresponding to different passwords. The password of levels are set by the highest level.
449 +**(1) Enable object password: **Check it to enable object security function. There are 12 levels corresponding to different passwords. The password of levels are set by the highest level.
553 553  
554 -* **Passwords for levels:** It is used for set password for every level, it is composed of numbers and letters (case sensitive)within 8 digits.
555 -* **Start level:** It is used for set initial level while this function is enabled.
556 -* **Highest level**: It is used for set how many levels of password could be used.
557 -* **Independent password:**
558 -** **Unchecked: **You should enter the corresponding level password when unlocking each level of object, and the higher level password could unlock the lower level object.
559 -** **Checked:** You could only type the corresponding level password when unlocking each level of object.
451 +1. **Passwords for levels:** It is used for set password for every level, it is composed of numbers and letters (case sensitive)within 8 digits.
452 +1. **Start level:** It is used for set initial level while this function is enabled.
453 +1. **Highest level**: It is used for set how many levels of password could be used.
454 +1. **Independent password:**
560 560  
456 +* **Unchecked: **You should enter the corresponding level password when unlocking each level of object, and the higher level password could unlock the lower level object.
457 +* **Checked:** You could only type the corresponding level password when unlocking each level of object.
458 +
561 561  ✎**Note:**
562 562  
563 563  * Object level password could be enabled in "Bit Switch", "Word Switch", "Function Switch", vCombination Switch", "Numeric Input", "Character Input", "Drop-down List" etc.
... ... @@ -568,7 +568,7 @@
568 568  * The configured password could not be empty, otherwise when users close the configuration screen ,there will be an error: "please set password for level".
569 569  * If configured object password level is higher than highest password setting in Project Settingss, there will be an error note during compiling: "the security level of this object is out of range!" .Users need to set password level again to solve the problem.
570 570  
571 -== Screen Lock ==
469 +== **{{id name="_Toc3790"/}}Screen Lock** ==
572 572  
573 573  The screen lock function provides another way for the security of HMI operation. When clients do not perform any operation for a set period of time, the HMI screen would be locked, and the password is required when HMI is operated again.
574 574  
... ... @@ -579,7 +579,7 @@
579 579  1. **Password:** this password is used for unlocking screen, it is composed of numbers and letters (case sensitive) within 8 digits.
580 580  1. **Lock time:** It is used for setting time how long the screen will be locked if users do not operate, range: 1 to 240 minutes (integer).
581 581  
582 -= Font pack =
480 += **Font pack** =
583 583  
584 584  "Font pack" is for setting built-in font for HMI project, in this way, the text in some objects of the HMI could be displayed in the desired font.
585 585  
... ... @@ -599,7 +599,7 @@
599 599  [[image:image-20220614173008-2.png]]
600 600  
601 601  (% start="5" %)
602 -1. Click OK to save settings.
500 +1. Click [OK] to save settings.
603 603  
604 604  **Result**
605 605  
DynamicScreensaver.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -2.7 KB
Content
ProjectSettingOverview.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -26.1 KB
Content
image-20220808091210-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -41.7 KB
Content
image-20220808092928-2.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -759.0 KB
Content
image-20220808093055-3.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -743.9 KB
Content
image-20220808093713-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -9.9 KB
Content
image-20220808093816-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -2.1 KB
Content
image-20220808094244-6.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -39.3 KB
Content
image-20220808094729-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -40.2 KB
Content
image-20220808095752-8.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -35.7 KB
Content
image-20220808100223-9.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -26.8 KB
Content
image-20220808100330-10.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -56.1 KB
Content
image-20220808100720-11.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -37.8 KB
Content