Changes for page 03 Project Settings
Last modified by Hunter on 2024/06/11 15:58
From version 23.1
edited by Karen
on 2023/05/25 15:56
on 2023/05/25 15:56
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Karen1 +XWiki.Jim - Content
-
... ... @@ -131,8 +131,6 @@ 131 131 132 132 == Switch action == 133 133 134 -**Introduction** 135 - 136 136 The "Switch action" provides the action trigger settings. It is the effect timing of when the button executes the action. 137 137 138 138 (% style="text-align:center" %) ... ... @@ -362,7 +362,7 @@ 362 362 363 363 == Special expansion == 364 364 365 -"Special Expansion" is for extending audio play and camera input functions for special HMI models.363 +"Special expansion" is for extending audio play and camera input functions for special HMI models. 366 366 367 367 (% style="text-align:center" %) 368 368 [[image:05.Project Settings_html_784d40de9b3e3bda.png||height="109" width="543"]] ... ... @@ -544,29 +544,28 @@ 544 544 545 545 == Objects password == 546 546 547 - Youshould enter password to access the protected object. This could avoid some misoperation on object. There are 12 levels in object password setting, and each level corresponds to each password.545 +Users should enter password to access the protected object. This could avoid some misoperation on object. There are 12 levels in object password setting, and each level corresponds to each password. 548 548 549 549 (% style="text-align:center" %) 550 550 [[image:05.Project Settings_html_4835fff86888a26b.png||height="238" width="502"]] 551 551 552 -**Enable object password: **Check it to enable object security function. There are 12 levels corresponding to different passwords. The password of levels areset by the highest level.550 +**Enable object password: **Check it to enable object security function. There are 12 levels corresponding to different passwords. The password of levels is set by the highest level. 553 553 554 -* **Passwords for levels:** It is used forset password for every level, it is composed of numbers and letters (case sensitive)within 8 digits.555 -* **Start level:** It is used forset initial level while this function is enabled.556 -* **Highest level**: It is used forset how many levels of password could be used.552 +* **Passwords for levels:** It is used to set password for every level, it is composed of numbers and letters (case sensitive)within 8 digits. 553 +* **Start level:** It is used to set initial level while this function is enabled. 554 +* **Highest level**: It is used to set how many levels of password could be used. 557 557 * **Independent password:** 558 558 ** **Unchecked: **You should enter the corresponding level password when unlocking each level of object, and the higher level password could unlock the lower level object. 559 559 ** **Checked:** You could only type the corresponding level password when unlocking each level of object. 560 560 561 -✎**Note:** 559 +(% class="box infomessage" %) 560 +✎**Note: **Object level password could be enabled in "Bit Switch", "Word Switch", "Function Switch", combination "Switch", "Numeric Input", "Character Input", "Drop-down List" etc. 562 562 563 -* Object level password could be enabled in "Bit Switch", "Word Switch", "Function Switch", vCombination Switch", "Numeric Input", "Character Input", "Drop-down List" etc. 564 - 565 565 (% style="text-align:center" %) 566 566 [[image:安全设置 2.png||class="img-thumbnail"]] 567 567 568 -* The configured password could not be empty, otherwise when users close the configuration screen please set password for level".569 -* If configured object password level is higher than highest password setting in Project Settingss, there will be an error note during compiling: " the security level of this object is out of range!" .Users need to set password level again to solve the problem.565 +* The configured password could not be empty, otherwise, when users close the configuration screen, there will be an error: "Please set password for level". 566 +* If configured object password level is higher than highest password setting in Project Settingss, there will be an error note during compiling: "The security level of this object is out of range!" . Users need to set password level again to solve the problem. 570 570 571 571 == Screen Lock == 572 572