Changes for page 03 Project Settings

Last modified by Hunter on 2024/06/11 15:58

From version 24.2
edited by Karen
on 2023/05/26 15:04
Change comment: There is no comment for this version
To version 14.1
edited by Stone Wu
on 2022/08/08 14:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Karen
1 +XWiki.Stone
Content
... ... @@ -4,7 +4,7 @@
4 4  
5 5  **Operating procedure**
6 6  
7 -Click "Project""Communication" to open setting window.
7 +Click "Project"->"Communication" to open setting window.
8 8  
9 9  (% style="text-align:center" %)
10 10  [[image:image-20220614172512-1.png]]
... ... @@ -43,7 +43,7 @@
43 43  == Project settings ==
44 44  
45 45  (% style="text-align:center" %)
46 -[[image:ProjectSettingOverview.png]]
46 +[[image:工程设置 1.png||class="img-thumbnail"]]
47 47  
48 48  == HMI model ==
49 49  
... ... @@ -83,19 +83,6 @@
83 83  ✎**Note**: When the Screensaver and the Screen Lock are enabled at the same time, the Screensaver can only be unlocked after unlocking the Screen Lock.
84 84  )))
85 85  
86 -== Enable Dynamic Screensaver ==
87 -
88 -Same as Screensaver. Dynamic Screensaver provides the function is that prevent the HMI from displaying the same screen for a long time due to unattended operation. But Dynamic will be able to display animation.
89 -
90 -(% style="text-align:center" %)
91 -[[image:DynamicScreensaver.png]]
92 -
93 -**Enable dynamic screensaver:** If the screen is not operated within the set waiting time, it will automatically enter the set animation effect, and operating the screen again will exit the dynamic screensaver.
94 -
95 -**Standby Time(minutes): **When the screen is not operated, the waiting interval to enter the dynamic screensaver, ranges 1~~720.
96 -
97 -**Animation Type:** Types of effects currently provided are Raster, Blinds, and Bubble.
98 -
99 99  == Initial screen ==
100 100  
101 101  The "Initial screen" provides the interface to user to set initial screen. Initial screen means the first one displayed screen when HMI is powered on.
... ... @@ -105,9 +105,9 @@
105 105  
106 106  **Operating Procedure**
107 107  
108 -1. Open "Project Settings" windows.
95 +1. Open [Project Settings] windows.
109 109  1. Select initial screen in drop-list, use screen 2 as an example.
110 -1. Click "OK" button to save setting and exit windows.
97 +1. Click [OK] button to save setting and exit windows.
111 111  
112 112  == Operation record ==
113 113  
... ... @@ -131,6 +131,8 @@
131 131  
132 132  == Switch action ==
133 133  
121 +**Introduction**
122 +
134 134  The "Switch action" provides the action trigger settings. It is the effect timing of when the button executes the action.
135 135  
136 136  (% style="text-align:center" %)
... ... @@ -233,7 +233,7 @@
233 233  1. Open "HMI IP" sub-window.
234 234  1. Check "HMI IP".
235 235  1. Enter IP.
236 -1. Click "OK" button to save setting and exit windows.
225 +1. {{id name="_Toc479868176"/}}{{id name="_Toc8172"/}}Click "OK" button to save setting and exit windows.
237 237  
238 238  == Remote access password ==
239 239  
... ... @@ -270,7 +270,7 @@
270 270  The expiry time and key of each period could not be empty, and they need to be configured in advance. And the expiry time of the latter period need to be later than the expiry of the previous period.
271 271  
272 272  1. **Use admin key: **It can be used for unlock all expirations,in addition to each period key.If users select [use admin key] function,once users enter the admin key when HMI expires,the installment payment function will be disabled.
273 -1. **Admin: **Password (Key) for "use admin key";
262 +1. **Admin: **Password (Key) for [use admin key];
274 274  1. **Max periods: **The period of static installment payment range is 0-12.When the maximum number of period is 0,it means that the instalment payment function is disabled;
275 275  1. **Begin Period: **Set the installment payment to start from the first period, the range is 1-13;
276 276  1. **List: **Configure a list based on [Maximum Periods] and [Begin Period],where user can configure the password and expiration time for each period.
... ... @@ -354,13 +354,13 @@
354 354  
355 355  1. Open "Project Settings" windows.
356 356  1. Open "Extend" sub-windows.
357 -1. Select "Startup" or "Running".
346 +1. Select "Startup" or [Running.
358 358  1. Set "Time".
359 359  1. Set "Password" if you require the password when entering the backstage interface.
360 360  
361 361  == Special expansion ==
362 362  
363 -"Special expansion" is for extending audio play and camera input functions for special HMI models.
352 +"Special Expansion" is for extending audio play and camera input functions for special HMI models.
364 364  
365 365  (% style="text-align:center" %)
366 366  [[image:05.Project Settings_html_784d40de9b3e3bda.png||height="109" width="543"]]
... ... @@ -397,8 +397,8 @@
397 397  
398 398  * These all three functions are not available for all HMIs, only special HMI models could support them.
399 399  * The details of "audio" settings, please refer to [[Audio>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HAudio]].
400 -* The details of "camera" settings, please refer to [[camera>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HrtspwebA0camera]].
401 -* The details of "mulit-link" settings, please refer to [[mulit-link>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HMulit-link]].
389 +* The details of ""camera" settings, please refer to [[camera>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HrtspwebA0camera]].
390 +* The details of ""mulit-link" settings, please refer to [[mulit-link>>https://docs.we-con.com.cn/bin/view/PIStudio/11.Advanced%20Function/#HMulit-link]].
402 402  )))
403 403  
404 404  == Input device ==
... ... @@ -509,8 +509,7 @@
509 509  * DataLogFile is data log record. It can only download files, but cannot upload files.
510 510  * RecipeFile is recipe. It can only download files, but cannot upload files.
511 511  * UserMgrFile is operation record. It can only download files, but cannot upload files.
512 -* Sdcard is the mounting directory of SD card. There will be the subdirectory of S1, S2, S3, etc. when connected SD card. It can upload and download.
513 -* Udisk is the mounting directory of USB flash drive. There will be the subdirectory of U1, U2, U3, etc. when connected USB flash drive. It can upload and download.
501 +* Sdcard is the mounting directory of SD card. There will be the subdirectory of S1 to Sn when connected SD card. It can upload and download.
514 514  
515 515  (% class="box infomessage" %)
516 516  (((
... ... @@ -538,7 +538,7 @@
538 538  Only when object password is set,object password function could be used in object.
539 539  
540 540  (% style="text-align:center" %)
541 -[[image:SecurityOverview.png]]
529 +[[image:安全设置 1.png||class="img-thumbnail"]]
542 542  
543 543  == Objects password ==
544 544  
... ... @@ -549,13 +549,14 @@
549 549  
550 550  **Enable object password: **Check it to enable object security function. There are 12 levels corresponding to different passwords. The password of levels are set by the highest level.
551 551  
552 -* **Passwords for levels:** It is used for set password for every level, it is composed of numbers and letters (case sensitive)within 8 digits.
553 -* **Start level:** It is used for set initial level while this function is enabled.
554 -* **Highest level**: It is used for set how many levels of password could be used.
555 -* **Independent password:**
556 -** **Unchecked: **You should enter the corresponding level password when unlocking each level of object, and the higher level password could unlock the lower level object.
557 -** **Checked:** You could only type the corresponding level password when unlocking each level of object.
540 +1. **Passwords for levels:** It is used for set password for every level, it is composed of numbers and letters (case sensitive)within 8 digits.
541 +1. **Start level:** It is used for set initial level while this function is enabled.
542 +1. **Highest level**: It is used for set how many levels of password could be used.
543 +1. **Independent password:**
558 558  
545 +* **Unchecked: **You should enter the corresponding level password when unlocking each level of object, and the higher level password could unlock the lower level object.
546 +* **Checked:** You could only type the corresponding level password when unlocking each level of object.
547 +
559 559  ✎**Note:**
560 560  
561 561  * Object level password could be enabled in "Bit Switch", "Word Switch", "Function Switch", vCombination Switch", "Numeric Input", "Character Input", "Drop-down List" etc.
... ... @@ -577,47 +577,6 @@
577 577  1. **Password:** this password is used for unlocking screen, it is composed of numbers and letters (case sensitive) within 8 digits.
578 578  1. **Lock time:** It is used for setting time how long the screen will be locked if users do not operate, range: 1 to 240 minutes (integer).
579 579  
580 -== LAN Monitoring Security ==
581 -
582 -(% style="text-align:center" %)
583 -[[image:SecurityOption.png]]
584 -
585 -In the same Local Area Network, user can enter the IP of the HMI on the webpage to achieve LAN monitoring of the HMI
586 -
587 -The terminal access number of remote monitoring or LAN monitoring for each series of HMI models is limited, as following table shows:
588 -
589 -|=(% scope="row" style="width: 182px;" %)Model|=(% style="width: 178px;" %)System Version|=(% style="width: 153px;" %)LAN Monitoring|=(% style="width: 260px;" %)Remote Monitoring|=(% style="width: 241px;" %)Supported visits number
590 -|=(% style="width: 182px;" %)3000|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
591 -|=(% style="width: 182px;" %)3000i|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
592 -|=(% style="width: 182px;" %)3000ie|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
593 -|=(% style="width: 182px;" %)3000ig-O|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
594 -|=(% style="width: 182px;" %)3000ig/3000ig-C|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
595 -|=(% style="width: 182px;" %)8000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
596 -|=(% style="width: 182px;" %)8000ig|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
597 -|=(% style="width: 182px;" %)9000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
598 -
599 -After this function is enabled, user name and password need to be entered for LAN monitoring, which can avoid some uncontrollable security problems to a certain extent;
600 -
601 -{{info}}
602 -✎Note: This LAN Monitoring Security function is only supported by HMI V2.0 system and above.
603 -{{/info}}
604 -
605 -**Webpage monitoring**:
606 -
607 -After enable this function, when user input IP to access HMI, you need to enter the user name and password configured by HMI in the login interface first, and then you can access after verification(The login interface supports switching language between Chinese and English, the default is Chinese)
608 -
609 -(% style="text-align:center" %)
610 -[[image:LANSercuityloginpage.png]]
611 -
612 -If it is not configured this function in the project, it also can modify from the background interface.
613 -
614 -System->Extend
615 -
616 -(% style="text-align:center" %)
617 -[[image:LANBackground.png]]
618 -
619 -
620 -
621 621  = Font pack =
622 622  
623 623  "Font pack" is for setting built-in font for HMI project, in this way, the text in some objects of the HMI could be displayed in the desired font.
... ... @@ -638,7 +638,7 @@
638 638  [[image:image-20220614173008-2.png]]
639 639  
640 640  (% start="5" %)
641 -1. Click OK to save settings.
589 +1. Click [OK] to save settings.
642 642  
643 643  **Result**
644 644  
DynamicScreensaver.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -2.7 KB
Content
LANBackground.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -652.7 KB
Content
LANSercuityloginpage.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -68.1 KB
Content
ProjectSettingOverview.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -26.1 KB
Content
SecurityOption.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -2.0 KB
Content
SecurityOverview.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -20.0 KB
Content