Changes for page 03 Project Settings
Last modified by Joe on 2026/10/08 15:26
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -693,18 +693,25 @@ 693 693 694 694 |=(% scope="row" style="width: 182px;" %)Model|=(% style="width: 178px;" %)System Version|=(% style="width: 153px;" %)LAN Monitoring|=(% style="width: 260px;" %)Remote Monitoring|=(% style="width: 241px;" %)Supported visits number 695 695 |=(% style="width: 182px;" %)3000|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1 696 -|=(% style="width: 182px;" %)3000i|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1 697 -|=(% style="width: 182px;" %)3000ie|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1 696 +|=(% style="width: 182px;" %)3000i*|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1 697 +|=(% style="width: 182px;" %)3000ie*|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1 698 698 |=(% style="width: 182px;" %)3000ig-O|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1 699 699 |=(% style="width: 182px;" %)3000ig/3000ig-C|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4 700 700 |=(% style="width: 182px;" %)8000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4 701 701 |=(% style="width: 182px;" %)8000ig|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4 702 702 |=(% style="width: 182px;" %)9000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4 703 +|=(% style="width: 182px;" %)9000ig|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4 703 703 704 704 After this function is enabled, user name and password need to be entered for LAN monitoring, which can avoid some uncontrollable security problems to a certain extent; 705 705 706 706 {{info}} 707 -✎Note: This LAN Monitoring Security function is only supported by HMI V2.0 system and above. 708 +✎Note: 709 + 710 +1.This LAN Monitoring Security function is only supported by HMI V2.0 system and above. 711 + 712 +2.LAN Monitoring can be supported by modules with network port in 3000i and 3000ie series. 713 + 714 +**3.The quantity limits for the charts shown above apply to both LAN monitoring and V-net remote screen functions.** 708 708 {{/info}} 709 709 710 710 **Webpage monitoring**: ... ... @@ -731,7 +731,7 @@ 731 731 Project Setting →Time Synchronization/DST 732 732 733 733 * **HMI Time Zone**: Customize the device's time zone. Once configured, the system time zone will be changed to the user-selected time zone. 734 -* **Synchronize HMI time with external device when HMI starts**: After enabling, select the** first address** to store time information. After configuration, read **six consecutive addresses** representing **year, month, day, hour, minute, and second.**741 +* **Synchronize HMI time with external device when HMI starts**: After enabling, select the** first address** to store time information. After configuration, read **six consecutive addresses** representing **year, month, day, hour, minute, and second.** 735 735 * **Enable Time Synchronization: ** 736 736 737 737 (% class="box infomessage" %) ... ... @@ -739,7 +739,7 @@ 739 739 **Note: NTP synchronization and external device synchronization are mutually exclusive; only one synchronization mode can be selected.** 740 740 ))) 741 741 742 -* **Run Time Synchronization When the HMI Starts:** Performs a time synchronization** immediately upon device startup**.749 +* **Run Time Synchronization When the HMI Starts:** Performs a time synchronization** immediately upon device startup**. 743 743 * **Primary Time Server :** The first time server is required and the others are optional. IP can be customized. The drop-down list shows commonly used time servers. 744 744 * **Update cycle:** After the project is downloaded to the device, the update interval is in seconds. The HMI will synchronize the time every update interval. 745 745 ... ... @@ -762,7 +762,7 @@ 762 762 (% style="text-align:center" %) 763 763 [[image:1.png]] 764 764 765 -**Register Configuration **772 +**Register Configuration ** 766 766 767 767 Except for the time zone and server IP address, all other configurations can be modified through registers. 768 768
- 1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.5 KB - Content