693 693  
694 694  |=(% scope="row" style="width: 182px;" %)Model|=(% style="width: 178px;" %)System Version|=(% style="width: 153px;" %)LAN Monitoring|=(% style="width: 260px;" %)Remote Monitoring|=(% style="width: 241px;" %)Supported visits number
695 695  |=(% style="width: 182px;" %)3000|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
696 -|=(% style="width: 182px;" %)3000i*|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
697 -|=(% style="width: 182px;" %)3000ie*|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
696 +|=(% style="width: 182px;" %)3000i|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
697 +|=(% style="width: 182px;" %)3000ie|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
698 698  |=(% style="width: 182px;" %)3000ig-O|(% style="width:178px" %)HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)×|(% style="width:241px" %)1
699 699  |=(% style="width: 182px;" %)3000ig/3000ig-C|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
700 700  |=(% style="width: 182px;" %)8000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
701 701  |=(% style="width: 182px;" %)8000ig|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
702 702  |=(% style="width: 182px;" %)9000|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
703 -|=(% style="width: 182px;" %)9000ig|(% style="width:178px" %)HMI V1.0/HMI V2.0|(% style="width:153px" %)✔|(% style="width:260px" %)✔|(% style="width:241px" %)4
704 704  
705 705  After this function is enabled, user name and password need to be entered for LAN monitoring, which can avoid some uncontrollable security problems to a certain extent;
706 706  
707 707  {{info}}
708 -✎Note:
709 -
710 -1.This LAN Monitoring Security function is only supported by HMI V2.0 system and above.
711 -
712 -2.LAN Monitoring can be supported by modules with network port in 3000i and 3000ie series.
713 -
714 -**3.The quantity limits for the charts shown above apply to both LAN monitoring and V-net remote screen functions.**
707 +✎Note: This LAN Monitoring Security function is only supported by HMI V2.0 system and above.
715 715  {{/info}}
716 716  
717 717  **Webpage monitoring**:
... ... @@ -738,7 +738,7 @@
738 738  Project Setting →Time Synchronization/DST
739 739  
740 740  * **HMI Time Zone**:  Customize the device's time zone. Once configured, the system time zone will be changed to the user-selected time zone.
741 -* **Synchronize HMI time with external device when HMI starts**: After enabling, select the** first address** to store time information. After configuration, read **six consecutive addresses** representing **year, month, day, hour, minute, and second.**
734 +* **Synchronize HMI time with external device when HMI starts**: After enabling, select the** first address** to store time information. After configuration, read **six consecutive addresses** representing **year, month, day, hour, minute, and second.**
742 742  * **Enable Time Synchronization: **
743 743  
744 744  (% class="box infomessage" %)
... ... @@ -746,7 +746,7 @@
746 746  **Note: NTP synchronization and external device synchronization are mutually exclusive; only one synchronization mode can be selected.**
747 747  )))
748 748  
749 -* **Run Time Synchronization When the HMI Starts:** Performs a time synchronization** immediately upon device startup**.
742 +* **Run Time Synchronization When the HMI Starts:** Performs a time synchronization** immediately upon device startup**.
750 750  * **Primary Time Server :** The first time server is required and the others are optional. IP can be customized. The drop-down list shows commonly used time servers.
751 751  * **Update cycle:** After the project is downloaded to the device, the update interval is in seconds. The HMI will synchronize the time every update interval.
752 752  
... ... @@ -769,7 +769,7 @@
769 769  (% style="text-align:center" %)
770 770  [[image:1.png]]
771 771  
772 -**Register Configuration   **
765 +**Register Configuration  **
773 773  
774 774  Except for the time zone and server IP address, all other configurations can be modified through registers.
775 775  
1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.joe
Size
... ... @@ -1,1 +1,0 @@
1 -35.5 KB
Content