Changes for page 05 Objects
Last modified by Jett on 2025/04/08 13:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1398,40 +1398,41 @@ 1398 1398 1399 1399 The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter. 1400 1400 1401 -**Description** 1401 +(% style="text-align:center" %) 1402 +[[image:image-20220805161001-1.jpeg]] 1402 1402 1404 +**Read address:** Read the value from the set PLC address. 1403 1403 1404 -(% style="text-align:center" %) 1405 -[[image:6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]] 1406 +**Data format:** It is for data setting. The data format types are as below. 1406 1406 1407 -**(1) Basic** 1408 +* BCD, 32-bit float 1409 +* signed decimal 1410 +* unsigned decimal 1411 +* 32-bit signed decimal 1412 +* 32-bit unsigned decimal 1408 1408 1409 -1. **Read address:** Read the value from the set PLC address. 1410 -1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal. 1411 -1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal. 1412 -1. **Min angle and max angle:** Data range, if data beyond range will be not inputted. 1413 -1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below; 1414 +**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address. 1414 1414 1415 -** (2)Showmeter background**1416 +* **Min angle and max angle:** Data range, if data beyond range will be not inputted. 1416 1416 1417 - Thisisfor settingmeter background, therearefourtypes,youcouldselectitaccordingto needs.1418 +**Variable limits:** when checked, low limit address and high limit address could be edit showed below; 1418 1418 1419 -** (3)Show pointer**1420 +**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs. 1420 1420 1421 -You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color. 1422 +**Show pointer**: When not checked, the pointer is not displayed; When checked, there are four styles of pointer meter to select it according to needs. You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color. 1422 1422 1423 -** (4)Show alarm area**1424 +**Show alarm area** 1424 1424 1425 1425 It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color. 1426 1426 1427 -** (5)Show scale**1428 +**Show scale** 1428 1428 1429 1429 It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them. 1430 1430 1431 -** (6)Meter angel settings**1432 +**Meter angel settings** 1432 1432 1433 - 1.**Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.1434 - 1.**Start angle: **It sets the position where the minimum value is displayed.1434 +* **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1435 +* **Start angle: **It sets the position where the minimum value is displayed. 1435 1435 1436 1436 **Result** 1437 1437 ... ... @@ -1441,7 +1441,10 @@ 1441 1441 [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]] 1442 1442 1443 1443 1445 +(% class="box infomessage" %) 1446 +((( 1444 1444 ✎**Note:** For the parameter setting, please refer to "[[text>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HText]]" in "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 1448 +))) 1445 1445 1446 1446 == **Bar** == 1447 1447
- image-20220805161001-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.3 KB - Content