Changes for page 05 Objects
Last modified by Jett on 2025/04/08 13:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -183,13 +183,12 @@ 183 183 184 184 **Description** 185 185 186 - 187 187 (% style="text-align:center" %) 188 188 [[image:6.Objects_html_273aed06eb8f10f9.gif||class="img-thumbnail"]] 189 189 190 -** (1)Address**: It is for setting specified PLC or HMI bit address。189 +**Address**: It is for setting specified PLC or HMI bit address。 191 191 192 -** (2)Hide**191 +**Hide** 193 193 194 194 * **Inverted Display: **Display reverse state of the picture and text. *for example, the value of write address is set ON, the OFF mode is displayed. 195 195 * **Blinking: **Blinking while control bit is triggered, the frequency is editable; ... ... @@ -1398,41 +1398,39 @@ 1398 1398 1399 1399 The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter. 1400 1400 1401 -**Description** 1402 - 1403 - 1404 1404 (% style="text-align:center" %) 1405 -[[image: 6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]]1401 +[[image:image-20220805161001-1.jpeg]] 1406 1406 1407 -** (1)Basic**1403 +**Read address:** Read the value from the set PLC address. 1408 1408 1409 -1. **Read address:** Read the value from the set PLC address. 1410 -1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal. 1411 -1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal. 1412 -1. **Min angle and max angle:** Data range, if data beyond range will be not inputted. 1413 -1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below; 1405 +**Data format:** It is for data setting. The data format types are as below. 1414 1414 1415 -**(2) Show meter background** 1407 +* BCD, 32-bit float 1408 +* signed decimal 1409 +* unsigned decimal 1410 +* 32-bit signed decimal 1411 +* 32-bit unsigned decimal 1416 1416 1417 - This isforsetting meterbackground, therearefour types,youcould select it accordingto needs.1413 +**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address. 1418 1418 1419 -** (3)Showpointer**1415 +* **Min angle and max angle:** Data range, if data beyond range will be not inputted. 1420 1420 1421 - You could selecthowpointer ornotaccording to need,anditprovidestwo typesforpointerandusers couldselectpointercolor.1417 +**Variable limits:** when checked, low limit address and high limit address could be edit showed below; 1422 1422 1423 -** (4)Show alarmarea**1419 +**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs. 1424 1424 1425 - Itprovides alarmfunctioninmeter,userscouldsetalarmrange, userscould set the4 ranges. Andeachrangecorrespondstoa differentalarm color.1421 +**Show pointer**: When not checked, the pointer is not displayed; When checked, you could set the style and color of pointer. 1426 1426 1427 -** (5)Showscale**1423 +**Show alarm area**: It provides alarm function in meter, you could set the 4 areas, and each area corresponds to a different alarm color. 1428 1428 1429 - It providessettingsforscale onmeter,userscould select[Major scale]and [Minor scale],and setcolorfor them.1425 +**Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value. 1430 1430 1431 -** (6)Meter angelsettings**1427 +**Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1432 1432 1433 -1. **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1434 -1. **Start angle: **It sets the position where the minimum value is displayed. 1429 +**Start angle: **It sets the position where the minimum value is displayed. 1435 1435 1431 +**Position&size:** Set the position of the object in the screen and the size of the object. The object is displayed as square. If the width or the height of the object is changed, the other data will also be changed. 1432 + 1436 1436 **Result** 1437 1437 1438 1438 When configuration is completed, the object is shown as below picture when HMI is running. ... ... @@ -1441,7 +1441,10 @@ 1441 1441 [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]] 1442 1442 1443 1443 1441 +(% class="box infomessage" %) 1442 +((( 1444 1444 ✎**Note:** For the parameter setting, please refer to "[[text>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HText]]" in "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 1444 +))) 1445 1445 1446 1446 == **Bar** == 1447 1447
- image-20220805161001-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.3 KB - Content