... ... @@ -183,13 +183,12 @@
183 183  
184 184  **Description**
185 185  
186 -
187 187  (% style="text-align:center" %)
188 188  [[image:6.Objects_html_273aed06eb8f10f9.gif||class="img-thumbnail"]]
189 189  
190 -**(1) Address**: It is for setting specified PLC or HMI bit address。
189 +**Address**: It is for setting specified PLC or HMI bit address。
191 191  
192 -**(2) Hide**
191 +**Hide**
193 193  
194 194  * **Inverted Display: **Display reverse state of the picture and text. *for example, the value of write address is set ON, the OFF mode is displayed.
195 195  * **Blinking: **Blinking while control bit is triggered, the frequency is editable;
... ... @@ -1398,41 +1398,39 @@
1398 1398  
1399 1399  The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1400 1400  
1401 -**Description**
1402 -
1403 -
1404 1404  (% style="text-align:center" %)
1405 -[[image:6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]]
1401 +[[image:image-20220805161001-1.jpeg]]
1406 1406  
1407 -**(1) Basic**
1403 +**Read address:** Read the value from the set PLC address.
1408 1408  
1409 -1. **Read address:** Read the value from the set PLC address.
1410 -1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal.
1411 -1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal.
1412 -1. **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1413 -1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1405 +**Data format:** It is for data setting. The data format types are as below.
1414 1414  
1415 -**(2) Show meter background**
1407 +* BCD, 32-bit float
1408 +* signed decimal
1409 +* unsigned decimal
1410 +* 32-bit signed decimal
1411 +* 32-bit unsigned decimal
1416 1416  
1417 -This is for setting meter background, there are four types, you could select it according to needs.
1413 +**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.
1418 1418  
1419 -**(3) Show pointer**
1415 +* **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1420 1420  
1421 -You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color.
1417 +**Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1422 1422  
1423 -**(4) Show alarm area**
1419 +**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs.
1424 1424  
1425 -It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color.
1421 +**Show pointer**: When not checked, the pointer is not displayed; When checked, you could set the style and color of pointer.
1426 1426  
1427 -**(5) Show scale**
1423 +**Show alarm area**: It provides alarm function in meter, you could set the 4 areas, and each area corresponds to a different alarm color.
1428 1428  
1429 -It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them.
1425 +**Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value.
1430 1430  
1431 -**(6) Meter angel settings**
1427 +**Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1432 1432  
1433 -1. **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1434 -1. **Start angle: **It sets the position where the minimum value is displayed.
1429 +**Start angle: **It sets the position where the minimum value is displayed.
1435 1435  
1431 +**Position&size:** Set the position of the object in the screen and the size of the object. The object is displayed as square. If the width or the height of the object is changed, the other data will also be changed.
1432 +
1436 1436  **Result**
1437 1437  
1438 1438  When configuration is completed, the object is shown as below picture when HMI is running.
... ... @@ -1441,7 +1441,10 @@
1441 1441  [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]]
1442 1442  
1443 1443  
1441 +(% class="box infomessage" %)
1442 +(((
1444 1444  ✎**Note:** For the parameter setting, please refer to "[[text>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HText]]" in "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]".
1444 +)))