Changes for page 05 Objects
Last modified by Hunter on 2026/07/14 14:46
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (2 modified, 0 added, 3 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.joe - Content
-
... ... @@ -32,13 +32,13 @@ 32 32 33 33 **Display** 34 34 35 -* **Inverted Display: **Display stheobject'sstate image and textinreverse state order.35 +* **Inverted Display: **Display the state picture and text of the object reversely. 36 36 * **Quick Read: **The priority of read and write is higher than any other objects on the same screen. 37 -* **Blink: ** When enabled, the bit switch blinkswhen the specifiedconditionismet;38 -** **Blink when ON: **Blink the bit switchwhen control bit is ON.39 -** **Blink when OFF: **Blink thebit switchwhen control bit is OFF.37 +* **Blink: **Blinking while control bit is triggered; 38 +** **Blink when ON: **Blink when control bit is ON. 39 +** **Blink when OFF: **Blink when control bit is OFF. 40 40 41 -**Minimum hold time: ** Specifiesthe press-and-holddurationrequired for the actiontotake effect.41 +**Minimum hold time: **Only when the time of press and hold the object is greater than the set value, the object function will be executed. 42 42 43 43 **Indirect addressing:** 44 44 ... ... @@ -245,7 +245,7 @@ 245 245 * **Decrease:** Decrease Operand value for each time the switch is triggered. 246 246 * **High/Low limit:** The value will be not able to change when the value reaches limits. 247 247 248 -**Min.Hold Time: **Specifiestheminimumintervalbetweenrepeatedtriggers.248 +**Min.Hold Time:**After continuously clicking the button for a period of time, the button will perform operations continuously 249 249 250 250 (% class="box infomessage" %) 251 251 ((( ... ... @@ -267,7 +267,7 @@ 267 267 **Address** 268 268 269 269 * **Read address:** Read the value from object display. 270 -* **States count: ** Specifiesthenumberofstatesforthe specifiedwordaddress, range: 1-256.270 +* **States count: **Total status number for current word address, which could change the state value according to different status in button [State values], range: 1-256. 271 271 * **State with value out of range**: When the value of the read address is not on the range of states' value, it will cause no corresponding status number is displayed. There are two modes for process when the value is out of range. 272 272 * **Hide**: Hide the object when the value is out of range; 273 273 * **Show state**: Specify a status when the value is out of range, for example the total states is 6(range from state No.0~~No.5), but the read value is 6, at this moment the object will show the state No.0 if selected item of show state is No.0; ... ... @@ -1408,7 +1408,7 @@ 1408 1408 1409 1409 (% class="box infomessage" %) 1410 1410 ((( 1411 -Only ig series HMI and R series V-boxhave this function.1411 +Only ig series have this function. 1412 1412 ))) 1413 1413 1414 1414 The recipe record display component displays recipe data in a table format and can perform operations such as adding, deleting, modifying, uploading, downloading, importing and exporting the recipe. ... ... @@ -1436,82 +1436,21 @@ 1436 1436 1437 1437 **Introduction:** Query all alarm records for a specific group number and display them in a table format in chronological order. The query time period can be dynamically set on HMI, and the display is saved after power-off. 1438 1438 1439 -(% class="box infomessage" %) 1440 -((( 1441 -Note: 1442 1442 1.Alarm Record in versions **10.0** and above are referred to as the "New Alarm Record," while those in versions below 10.0 are referred to as the "Old Alarm Record." 1440 + 1443 1443 2.Differences between New Alarm Record and Old Alarm Record: 1442 + 1444 1444 ① Clearer page configuration, divided into three main pages: "Basic," "Graphics," and "Alarm Properties." 1444 + 1445 1445 ② Appearance settings offer more style settings. 1446 + 1446 1446 ③ Added alarm property settings, allowing to change the color when confirming. 1448 + 1447 1447 ④ The ability to configure function addresses and query time periods in the project configuration has been removed. Instead, directly query and filter time periods and group numbers at runtime. 1450 + 1448 1448 ⑤Added horizontal and vertical scroll bars for easier screen navigation. 1449 -))) 1450 1450 1451 -**General:** 1452 1452 1453 -**1.Alarm Type :** There are three alarm modes including Current alarm record, History alarm record and Alarm event statistics. 1454 - 1455 -**(1) Current alarm records:** Only the current alarm record will be displayed. If the alarm is triggered, the record will disappear. 1456 - 1457 -**(2) Historical alarm records: **All alarm and alarm trigger records will be displayed one by one. 1458 - 1459 -**(3) Alarm event statistics:** Only one record for the same alarm address will be displayed. 1460 - 1461 -**2.Group number range**: The group number range of the alarm records to be displayed. Alarm records that are not in this range will not be displayed. 1462 - 1463 -**3.Time setting**: Select the display format of time and date. 1464 - 1465 - 1466 -(% style="text-align:center" %) 1467 -[[image:屏幕截图 2025-09-05 164650.png]] 1468 - 1469 -**Graphic:** 1470 - 1471 -**1.Style Selection:** Select a system-provided style from the Style Selection menu, or select "Custom" to customize the colors. 1472 - 1473 -(% class="box infomessage" %) 1474 -((( 1475 -Note: If select a system-provided style, the table color can not be changed. 1476 -))) 1477 - 1478 -**2.Cell format:** Includes two options: "Adaptive" and "Custom" 1479 - 1480 -**①Adaptive:** Cells automatically adjust size based on text length. 1481 - 1482 -**②Custom: **Manually set column widths and row heights for all cells. 1483 - 1484 -(% style="text-align:center" %) 1485 -[[image:屏幕截图 2025-09-05 164729.png]] 1486 - 1487 -**Alaem Properties** 1488 - 1489 -**1.Alarm Display Status** 1490 - 1491 -**(1) Confirm:** Set the text and background color for confirming an alarm record. 1492 - 1493 -(% class="box infomessage" %) 1494 -((( 1495 -Note: "Confirm" must be selected for the alarm to display successfully. 1496 -))) 1497 - 1498 -**(2)Back to normal:** Set the text and background color for the record when the alarm record returns to normal. 1499 - 1500 -**2. Sorting** 1501 - 1502 -**(1)Method:** Indicates the field to sort by. The default is time. 1503 - 1504 -**(2) Order:** Indicates the order to sort by. The default is descending order. 1505 - 1506 -**(3) Confirm: **Sets the method for confirming an alarm record and the write address. 1507 - 1508 -**① Confirmation Method: **The method for confirming an alarm record. There are three methods including single-click, double-click, and long press for 3 seconds. The default is single-click. 1509 - 1510 -**②Write Address:** The write address to be written during confirmation. Confirming will reset the contents of the write address to 0. 1511 - 1512 -(% style="text-align:center" %) 1513 -[[image:123.png]] 1514 - 1515 1515 == **Meter** == 1516 1516 1517 1517 (% style="text-align:center" %) ... ... @@ -2108,6 +2108,8 @@ 2108 2108 If the "Camera Search Module" is not enabled, you need to enter the camera information manually: user name, password, device serial number (S/N), which can be obtained from the label on the camera body. 2109 2109 ))) 2110 2110 2050 +(% style="text-align:center" %) 2051 +[[image:图片1.png]] 2111 2111 2112 2112 2113 2113 * (((
- 123.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.1 KB - Content
- 图片2.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 28.7 KB1 +17.1 KB - Content
- 图片3.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 62.6KB1 +1.7 KB - Content
- 屏幕截图 2025-09-05 164650.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.7 KB - Content
- 屏幕截图 2025-09-05 164729.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.4 KB - Content