Changes for page 05 Objects

Last modified by Jett on 2025/04/08 13:50

From version 18.2
edited by Stone Wu
on 2022/08/05 16:17
Change comment: There is no comment for this version
To version 17.1
edited by Stone Wu
on 2022/08/05 10:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1398,25 +1398,20 @@
1398 1398  
1399 1399  The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1400 1400  
1401 -(% style="text-align:center" %)
1402 -[[image:image-20220805161001-1.jpeg]]
1401 +**Description**
1403 1403  
1404 -**Read address:** Read the value from the set PLC address.
1405 1405  
1406 -**Data format:** It is for data setting. The data format types are as below.
1404 +(% style="text-align:center" %)
1405 +[[image:6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]]
1407 1407  
1408 -* BCD, 32-bit float
1409 -* signed decimal
1410 -* unsigned decimal
1411 -* 32-bit signed decimal
1412 -* 32-bit unsigned decimal
1407 +**(1) Basic**
1413 1413  
1414 -**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.
1409 +1. **Read address:** Read the value from the set PLC address.
1410 +1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal.
1411 +1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal.
1412 +1. **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1413 +1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1415 1415  
1416 -* **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1417 -
1418 -**Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1419 -
1420 1420  **(2) Show meter background**
1421 1421  
1422 1422  This is for setting meter background, there are four types, you could select it according to needs.
... ... @@ -1677,44 +1677,39 @@
1677 1677  
1678 1678  Rotation picture can rotate the image at a specified center or rotate it in a certain way. It is determined by the property settings.
1679 1679  
1675 +**Description**
1676 +
1680 1680  (% style="text-align:center" %)
1681 -[[image:image-20220805155253-1.jpeg]]
1678 +[[image:6.Objects_html_e43758e6e4e3e685.gif||class="img-thumbnail"]]
1682 1682  
1680 +**1) Counter-Clockwise**
1683 1683  
1684 -**Position: **Display the position of the rotation picture in the screen.
1682 +It sets the rotation direction of the picture. The default is to rotate clockwise. When checked, the rotation direction is counterclockwise.
1685 1685  
1686 -**Counter-Clockwise: **It sets the rotation direction of the picture. The default is to rotate clockwise. When checked, the rotation direction is counterclockwise.
1684 +**2) Appearance**
1687 1687  
1688 -**Appearance**: It sets picture for object, the picture is selected from Shape.
1686 +It sets picture for object, the picture is selected from Shape.
1689 1689  
1690 -**Data format**
1688 +**3) Data format**
1691 1691  
1692 1692  * **Data format: **It sets data format for [Address]->[Rotation angle].
1693 -** BCD
1694 -** 32-bit float
1695 -** 16-bit signed decimal
1696 -** 16-bit unsigned decimal
1697 -** 32-bit signed decimal
1698 -** 32-bit unsigned decimal
1699 1699  * **Min. angle:** It sets the starting angle of rotation (Valid in auto-rotation mode).
1700 1700  * **Max. angle:** It sets the ending angle of rotation (Valid in auto-rotation mode).
1701 1701  
1702 -**Rotation angle: **the rotating angle is determined by designated address;
1694 +**4) Address**
1703 1703  
1704 -**Rotation center**: It shows the rotation center coordinates;
1696 +**Rotation angle:**the rotating angle is determined by designated address; this mode and auto-rotation mode could not be used at the same time.
1705 1705  
1706 -**Auto-rotation: **Taker the center of the image as the center of the picture when it is rotating.
1698 +**5) Rotation center**
1707 1707  
1708 -**Cycle time: **Object will rotate every cycle time. Unit:100 ms.
1700 +It shows the rotation center coordinates;
1709 1709  
1710 -**Rotation angle:** Object rotates designated angle everytime.
1702 +**6) Auto-rotation**
1711 1711  
1712 -**Return:** Object will be reset to original position after maximum angle reached.
1704 +* **Cycle time: **Object will rotate every cycle time. Unit:100 ms.
1705 +* **Rotation angle:** Object rotates designated angle everytime.
1706 +* **Return:** Object will be reset to original position after maximum angle reached.
1713 1713  
1714 -**Enable auto-spin: **When the address is set to ON, the picture will rotate automatically.
1715 -
1716 -**Hide:** control the hiding status of the object through the status of the control bit address. The hiding mode can be divided into hide when OFF and hide when ON.
1717 -
1718 1718  == **Drop-down List** ==
1719 1719  
1720 1720  Drop-Down list is designed for display the designated state by text, to select the text in the list, the corresponding state will change, and the write address will change to the designated state value.
image-20220805155253-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -47.1 KB
Content
image-20220805161001-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -51.3 KB
Content