Changes for page 05 Objects
Last modified by Jett on 2025/04/08 13:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1398,25 +1398,20 @@ 1398 1398 1399 1399 The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter. 1400 1400 1401 -(% style="text-align:center" %) 1402 -[[image:image-20220805161001-1.jpeg]] 1401 +**Description** 1403 1403 1404 -**Read address:** Read the value from the set PLC address. 1405 1405 1406 -**Data format:** It is for data setting. The data format types are as below. 1404 +(% style="text-align:center" %) 1405 +[[image:6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]] 1407 1407 1408 -* BCD, 32-bit float 1409 -* signed decimal 1410 -* unsigned decimal 1411 -* 32-bit signed decimal 1412 -* 32-bit unsigned decimal 1407 +**(1) Basic** 1413 1413 1414 -**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address. 1409 +1. **Read address:** Read the value from the set PLC address. 1410 +1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal. 1411 +1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal. 1412 +1. **Min angle and max angle:** Data range, if data beyond range will be not inputted. 1413 +1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below; 1415 1415 1416 -* **Min angle and max angle:** Data range, if data beyond range will be not inputted. 1417 - 1418 -**Variable limits:** when checked, low limit address and high limit address could be edit showed below; 1419 - 1420 1420 **(2) Show meter background** 1421 1421 1422 1422 This is for setting meter background, there are four types, you could select it according to needs. ... ... @@ -1677,44 +1677,39 @@ 1677 1677 1678 1678 Rotation picture can rotate the image at a specified center or rotate it in a certain way. It is determined by the property settings. 1679 1679 1675 +**Description** 1676 + 1680 1680 (% style="text-align:center" %) 1681 -[[image: image-20220805155253-1.jpeg]]1678 +[[image:6.Objects_html_e43758e6e4e3e685.gif||class="img-thumbnail"]] 1682 1682 1680 +**1) Counter-Clockwise** 1683 1683 1684 - **Position:**Displaythe positionofthe rotationpicturethescreen.1682 +It sets the rotation direction of the picture. The default is to rotate clockwise. When checked, the rotation direction is counterclockwise. 1685 1685 1686 -** Counter-Clockwise:**It sets the rotation direction of thepicture. The default is torotate clockwise. Whenhecked, the rotation direction is counterclockwise.1684 +**2) Appearance** 1687 1687 1688 - **Appearance**:It sets picture for object, the picture is selected from Shape.1686 +It sets picture for object, the picture is selected from Shape. 1689 1689 1690 -**Data format** 1688 +**3) Data format** 1691 1691 1692 1692 * **Data format: **It sets data format for [Address]->[Rotation angle]. 1693 -** BCD 1694 -** 32-bit float 1695 -** 16-bit signed decimal 1696 -** 16-bit unsigned decimal 1697 -** 32-bit signed decimal 1698 -** 32-bit unsigned decimal 1699 1699 * **Min. angle:** It sets the starting angle of rotation (Valid in auto-rotation mode). 1700 1700 * **Max. angle:** It sets the ending angle of rotation (Valid in auto-rotation mode). 1701 1701 1702 -** Rotationangle: **the rotating angle isdeterminedby designated address;1694 +**4) Address** 1703 1703 1704 -**Rotation center**:It shows the rotationcentercoordinates;1696 +**Rotation angle:**the rotating angle is determined by designated address; this mode and auto-rotation mode could not be used at the same time. 1705 1705 1706 -** Auto-rotation:**Taker thecenterof the image as the center of the picture when it is rotating.1698 +**5) Rotation center** 1707 1707 1708 - **Cycletime:**Objectwillrotateeverycycle time. Unit:100 ms.1700 +It shows the rotation center coordinates; 1709 1709 1710 -** Rotationangle:** Objectes designated angle everytime.1702 +**6) Auto-rotation** 1711 1711 1712 -**Return:** Object will be reset to original position after maximum angle reached. 1704 +* **Cycle time: **Object will rotate every cycle time. Unit:100 ms. 1705 +* **Rotation angle:** Object rotates designated angle everytime. 1706 +* **Return:** Object will be reset to original position after maximum angle reached. 1713 1713 1714 -**Enable auto-spin: **When the address is set to ON, the picture will rotate automatically. 1715 - 1716 -**Hide:** control the hiding status of the object through the status of the control bit address. The hiding mode can be divided into hide when OFF and hide when ON. 1717 - 1718 1718 == **Drop-down List** == 1719 1719 1720 1720 Drop-Down list is designed for display the designated state by text, to select the text in the list, the corresponding state will change, and the write address will change to the designated state value.
- image-20220805155253-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -47.1 KB - Content
- image-20220805161001-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -51.3 KB - Content