... ... @@ -1398,25 +1398,20 @@
1398 1398  
1399 1399  The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1400 1400  
1401 -(% style="text-align:center" %)
1402 -[[image:image-20220805161001-1.jpeg]]
1401 +**Description**
1403 1403  
1404 -**Read address:** Read the value from the set PLC address.
1405 1405  
1406 -**Data format:** It is for data setting. The data format types are as below.
1404 +(% style="text-align:center" %)
1405 +[[image:6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]]
1407 1407  
1408 -* BCD, 32-bit float
1409 -* signed decimal
1410 -* unsigned decimal
1411 -* 32-bit signed decimal
1412 -* 32-bit unsigned decimal
1407 +**(1) Basic**
1413 1413  
1414 -**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.
1409 +1. **Read address:** Read the value from the set PLC address.
1410 +1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal.
1411 +1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal.
1412 +1. **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1413 +1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1415 1415  
1416 -* **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1417 -
1418 -**Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1419 -
1420 1420  **(2) Show meter background**
1421 1421  
1422 1422  This is for setting meter background, there are four types, you could select it according to needs.