Changes for page 05 Objects
Last modified by Hunter on 2026/07/14 14:46
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -286,7 +286,7 @@ 286 286 **Transform state** 287 287 288 288 * **Quick Read: **The priority of read and write is higher than any other objects on the same screen. 289 -* **Auto transform:** Objectswitch statesautomatically289 +* **Auto transforms:** The lamp automatically switches between states. 290 290 291 291 (% style="text-align:center" %) 292 292 [[image:6.Objects_html_b643c9a6a4bd6919.gif||class="img-thumbnail"]] ... ... @@ -294,7 +294,7 @@ 294 294 * **Trigger to transform: **Specifies the trigger condition for Auto Transform. 295 295 * **Auto return:** Return to the initial state after reaching the final state; 296 296 * **Time of transform:** Set the interval of transform between two states; 297 -* **Dynamic interval: **Setthedynamicintervaloftransformbetweentwo states. If the value in address is 10, then the frequency of automatic switching state is 10*100ms = 1s.297 +* **Dynamic time: **Specifies the address used to control the automatic state switching interval. If the value in address is 10, then the frequency of automatic switching state is 10*100ms = 1s. 298 298 299 299 **Manual** 300 300 ... ... @@ -301,10 +301,11 @@ 301 301 (% style="text-align:center" %) 302 302 [[image:6.Objects_html_a8b6636bd862369c.gif||class="img-thumbnail"]] 303 303 304 -* **S etstate: **Seta constant value to address(according to the operate state selection) when click the object.304 +* **State set: **Set state value to word address(according to the operate state selection) when click the lamp object. 305 305 * **State increase: **Increase the address value by one step when click the object, the upper limit is depends on the Last state selection. 306 306 * **State decrease:** Decrease the address value by one step when click the object, the lower limit is depends on the Last state selection.. 307 -* **Last state: **The upper limit or lower limit(Final state) of state increase/decrease; 307 +* **Last state: **The final state after the change; 308 +* **Return to state:** The word lamp returns to the selected state option when click the final state. 308 308 309 309 (% class="box infomessage" %) 310 310 ((( ... ... @@ -338,8 +338,8 @@ 338 338 (% style="text-align:center" %) 339 339 [[image:6.Objects_html_31c4ad387507a16d.gif||class="img-thumbnail"]] 340 340 341 -* **Screen No: ** Switchto the selected screen, it could not be subscreen;342 -* **Open sub screen: ** Pop-up selectedsubscreen,and set subscreenposition, default position is (0, 0), this is the coordinates of the top left corner of the screen;342 +* **Screen No: **The screen number to jump to, it could not be subscreen; 343 +* **Open sub screen: **The sub-screen number to pop up, default position is (0, 0), this is the coordinates of the top left corner of the screen; 343 343 344 344 (% style="text-align:center" %) 345 345 [[image:6.Objects_html_8b9a9cc4cb589d5b.gif||class="img-thumbnail"]] ... ... @@ -628,7 +628,7 @@ 628 628 * **Read Address:** The data from designated address will be displayed. 629 629 * **Input: **Enable input function and "Write Address" configuration. 630 630 * **Same read-write address:** Configure "Write Address" is the same as "Read Address". 631 -* **Read DWord: **Read t headdressdataatdoublebyteformat.632 +* **Read DWord: **Read one byte from each two-byte unit. For example, the string "abcd" is displayed as "ac". 632 632 * **Write address: **Write data to designated address. The address could be different "Read Address". 633 633 * **Keypad:** Built-in character keyboard input(Screen No.1001) could allow input a~~z, A~~Z, 0~~9. 634 634 * **Note**: After the keypad is opened, the content of note will be input into special register HUW1402. The maximum length allowed for the note is 63 characters.