Changes for page 05 Objects
Last modified by Jett on 2025/04/08 13:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1417,27 +1417,19 @@ 1417 1417 1418 1418 **Variable limits:** when checked, low limit address and high limit address could be edit showed below; 1419 1419 1420 -** (2)Show meter background**1420 +**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs. 1421 1421 1422 - Thisis forsettingmeterbackground, thereare four types, you could selectit accordingto needs.1422 +**Show pointer**: When not checked, the pointer is not displayed; When checked, you could set the style and color of pointer. 1423 1423 1424 -** (3)Show pointer**1424 +**Show alarm area**: It provides alarm function in meter, you could set the 4 areas, and each area corresponds to a different alarm color. 1425 1425 1426 - Youcouldselect showpointerornotaccordingto need,and itprovidestwotypesforpointeranduserscould selectpointer color.1426 +**Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value. 1427 1427 1428 -** (4)Showalarmarea**1428 +**Meter angel settings** 1429 1429 1430 -It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color. 1430 +* **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1431 +* **Start angle: **It sets the position where the minimum value is displayed. 1431 1431 1432 -**(5) Show scale** 1433 - 1434 -It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them. 1435 - 1436 -**(6) Meter angel settings** 1437 - 1438 -1. **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1439 -1. **Start angle: **It sets the position where the minimum value is displayed. 1440 - 1441 1441 **Result** 1442 1442 1443 1443 When configuration is completed, the object is shown as below picture when HMI is running. ... ... @@ -1446,7 +1446,10 @@ 1446 1446 [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]] 1447 1447 1448 1448 1441 +(% class="box infomessage" %) 1442 +((( 1449 1449 ✎**Note:** For the parameter setting, please refer to "[[text>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HText]]" in "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 1444 +))) 1450 1450 1451 1451 == **Bar** == 1452 1452