Changes for page 05 Objects

Last modified by Jett on 2025/04/08 13:50

From version 18.4
edited by Stone Wu
on 2022/08/05 16:26
Change comment: (Autosaved)
To version 18.1
edited by Stone Wu
on 2022/08/05 16:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1398,45 +1398,40 @@
1398 1398  
1399 1399  The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1400 1400  
1401 -(% style="text-align:center" %)
1402 -[[image:image-20220805161001-1.jpeg]]
1401 +**Description**
1403 1403  
1404 -**Read address:** Read the value from the set PLC address.
1405 1405  
1406 -**Data format:** It is for data setting. The data format types are as below.
1404 +(% style="text-align:center" %)
1405 +[[image:6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]]
1407 1407  
1408 -* BCD, 32-bit float
1409 -* signed decimal
1410 -* unsigned decimal
1411 -* 32-bit signed decimal
1412 -* 32-bit unsigned decimal
1407 +**(1) Basic**
1413 1413  
1414 -**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.
1409 +1. **Read address:** Read the value from the set PLC address.
1410 +1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal.
1411 +1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal.
1412 +1. **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1413 +1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1415 1415  
1416 -* **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1415 +**(2) Show meter background**
1417 1417  
1418 -**Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1419 -
1420 -**Show meter background**
1421 -
1422 1422  This is for setting meter background, there are four types, you could select it according to needs.
1423 1423  
1424 -**Show pointer**
1419 +**(3) Show pointer**
1425 1425  
1426 1426  You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color.
1427 1427  
1428 -**Show alarm area**
1423 +**(4) Show alarm area**
1429 1429  
1430 1430  It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color.
1431 1431  
1432 -**Show scale**
1427 +**(5) Show scale**
1433 1433  
1434 1434  It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them.
1435 1435  
1436 -**Meter angel settings**
1431 +**(6) Meter angel settings**
1437 1437  
1438 -* **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1439 -* **Start angle: **It sets the position where the minimum value is displayed.
1433 +1. **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1434 +1. **Start angle: **It sets the position where the minimum value is displayed.
1440 1440  
1441 1441  **Result**
1442 1442  
... ... @@ -1446,10 +1446,7 @@
1446 1446  [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]]
1447 1447  
1448 1448  
1449 -(% class="box infomessage" %)
1450 -(((
1451 1451  ✎**Note:** For the parameter setting, please refer to "[[text>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HText]]" in "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]".
1452 -)))
1453 1453  
1454 1454  == **Bar** ==
1455 1455  
image-20220805161001-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -51.3 KB
Content