Changes for page 05 Objects

Last modified by Jett on 2025/04/08 13:50

From version 18.5
edited by Stone Wu
on 2022/08/05 16:31
Change comment: (Autosaved)
To version 18.1
edited by Stone Wu
on 2022/08/05 16:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1398,41 +1398,40 @@
1398 1398  
1399 1399  The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1400 1400  
1401 -(% style="text-align:center" %)
1402 -[[image:image-20220805161001-1.jpeg]]
1401 +**Description**
1403 1403  
1404 -**Read address:** Read the value from the set PLC address.
1405 1405  
1406 -**Data format:** It is for data setting. The data format types are as below.
1404 +(% style="text-align:center" %)
1405 +[[image:6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]]
1407 1407  
1408 -* BCD, 32-bit float
1409 -* signed decimal
1410 -* unsigned decimal
1411 -* 32-bit signed decimal
1412 -* 32-bit unsigned decimal
1407 +**(1) Basic**
1413 1413  
1414 -**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.
1409 +1. **Read address:** Read the value from the set PLC address.
1410 +1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal.
1411 +1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal.
1412 +1. **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1413 +1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1415 1415  
1416 -* **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1415 +**(2) Show meter background**
1417 1417  
1418 -**Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1417 +This is for setting meter background, there are four types, you could select it according to needs.
1419 1419  
1420 -**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs.
1419 +**(3) Show pointer**
1421 1421  
1422 -**Show pointer**: When not checked, the pointer is not displayed; When checked, there are four styles of pointer meter to select it according to needs. You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color.
1421 +You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color.
1423 1423  
1424 -**Show alarm area**
1423 +**(4) Show alarm area**
1425 1425  
1426 1426  It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color.
1427 1427  
1428 -**Show scale**
1427 +**(5) Show scale**
1429 1429  
1430 1430  It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them.
1431 1431  
1432 -**Meter angel settings**
1431 +**(6) Meter angel settings**
1433 1433  
1434 -* **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1435 -* **Start angle: **It sets the position where the minimum value is displayed.
1433 +1. **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1434 +1. **Start angle: **It sets the position where the minimum value is displayed.
1436 1436  
1437 1437  **Result**
1438 1438  
... ... @@ -1442,10 +1442,7 @@
1442 1442  [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]]
1443 1443  
1444 1444  
1445 -(% class="box infomessage" %)
1446 -(((
1447 1447  ✎**Note:** For the parameter setting, please refer to "[[text>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HText]]" in "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]".
1448 -)))
1449 1449  
1450 1450  == **Bar** ==
1451 1451  
image-20220805161001-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -51.3 KB
Content