Changes for page 05 Objects
Last modified by Jett on 2025/04/08 13:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -183,13 +183,12 @@ 183 183 184 184 **Description** 185 185 186 - 187 187 (% style="text-align:center" %) 188 188 [[image:6.Objects_html_273aed06eb8f10f9.gif||class="img-thumbnail"]] 189 189 190 -** (1)Address**: It is for setting specified PLC or HMI bit address。189 +**Address**: It is for setting specified PLC or HMI bit address。 191 191 192 -** (2)Hide**191 +**Hide** 193 193 194 194 * **Inverted Display: **Display reverse state of the picture and text. *for example, the value of write address is set ON, the OFF mode is displayed. 195 195 * **Blinking: **Blinking while control bit is triggered, the frequency is editable; ... ... @@ -1419,21 +1419,18 @@ 1419 1419 1420 1420 **Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs. 1421 1421 1422 -**Show pointer**: When not checked, the pointer is not displayed; When checked, there are four stylesof pointer meter to select it according to needs. You could selectshow pointeror not according to need, and it provideswo typesfor pointeranduserscouldselectpointercolor.1421 +**Show pointer**: When not checked, the pointer is not displayed; When checked, you could set the style and color of pointer. 1423 1423 1424 -**Show alarm area** 1423 +**Show alarm area**: It provides alarm function in meter, you could set the 4 areas, and each area corresponds to a different alarm color. 1425 1425 1426 - It providesalarmfunctionin meter,userscould setalarm range,userscouldsetthe4 ranges.Andeach rangecorrespondsto adifferentalarmcolor.1425 +**Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value. 1427 1427 1428 -** Showscale**1427 +**Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1429 1429 1430 - Itprovides settingsfor scaleon meter,userscouldselect[Majorscale]and [Minorscale],andsetcolor for them.1429 +**Start angle: **It sets the position where the minimum value is displayed. 1431 1431 1432 -** Meter angel settings**1431 +**Position&size:** Set the position of the object in the screen and the size of the object. The object is displayed as square. If the width or the height of the object is changed, the other data will also be changed. 1433 1433 1434 -* **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1435 -* **Start angle: **It sets the position where the minimum value is displayed. 1436 - 1437 1437 **Result** 1438 1438 1439 1439 When configuration is completed, the object is shown as below picture when HMI is running.