Changes for page 05 Objects
Last modified by Jett on 2025/04/08 13:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1398,37 +1398,40 @@ 1398 1398 1399 1399 The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter. 1400 1400 1401 +**Description** 1402 + 1403 + 1401 1401 (% style="text-align:center" %) 1402 -[[image: image-20220805161001-1.jpeg]]1405 +[[image:6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]] 1403 1403 1404 -** Readaddress:**Read the value from the set PLC address.1407 +**(1) Basic** 1405 1405 1406 -**Data format:** It is for data setting. The data format types are as below. 1409 +1. **Read address:** Read the value from the set PLC address. 1410 +1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal. 1411 +1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal. 1412 +1. **Min angle and max angle:** Data range, if data beyond range will be not inputted. 1413 +1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below; 1407 1407 1408 -* BCD, 32-bit float 1409 -* signed decimal 1410 -* unsigned decimal 1411 -* 32-bit signed decimal 1412 -* 32-bit unsigned decimal 1415 +**(2) Show meter background** 1413 1413 1414 - **Digitssetting:**setdirectly the maximum and the minimum. Only when thefloating point numberisselected, canthe the maximum andminimum valuebewithadecimal point,and otherdataformatcan'tbewitha decimal point. If the value is readby the address, then select"variable limits",andfill in theaddress.1417 +This is for setting meter background, there are four types, you could select it according to needs. 1415 1415 1416 -* *Minangle and max angle:** Data range, if data beyond rangewillbe notinputted.1419 +**(3) Show pointer** 1417 1417 1418 - **Variablelimits:**when checked,lowlimitaddressandhigh limit addresscouldbeditshowedbelow;1421 +You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color. 1419 1419 1420 -**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointermeterto select itaccording to needs.1423 +**(4) Show alarm area** 1421 1421 1422 - **Showpointer**:Whennotchecked,the pointerisnotdisplayed;Whenchecked,you could set the style andcolorfpointer.1425 +It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color. 1423 1423 1424 -**Show al arm area**: It provides alarm function in meter, you could set the 4 areas, and each area corresponds to a different alarm color.1427 +**(5) Show scale** 1425 1425 1426 - **Showscale**: Displaythescale ontheobjectto observethe value.Youneedtosetmajor scale,minor scale and scalevalue.1429 +It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them. 1427 1427 1428 -**Meter angel settings** 1431 +**(6) Meter angel settings** 1429 1429 1430 - ***Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.1431 - ***Start angle: **It sets the position where the minimum value is displayed.1433 +1. **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1434 +1. **Start angle: **It sets the position where the minimum value is displayed. 1432 1432 1433 1433 **Result** 1434 1434 ... ... @@ -1438,10 +1438,7 @@ 1438 1438 [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]] 1439 1439 1440 1440 1441 -(% class="box infomessage" %) 1442 -((( 1443 1443 ✎**Note:** For the parameter setting, please refer to "[[text>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HText]]" in "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 1444 -))) 1445 1445 1446 1446 == **Bar** == 1447 1447
- image-20220805161001-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -51.3 KB - Content