1418 1418  **Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1419 1419  
1420 -**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs.
1420 +**(2) Show meter background**
1421 1421  
1422 -**Show pointer**: When not checked, the pointer is not displayed; When checked, you could set the style and color of pointer.
1422 +This is for setting meter background, there are four types, you could select it according to needs.
1423 1423  
1424 -**Show alarm area**: It provides alarm function in meter, you could set the 4 areas, and each area corresponds to a different alarm color.
1424 +**(3) Show pointer**
1425 1425  
1426 -**Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value.
1426 +You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color.
1427 1427  
1428 -**Meter angel settings**
1428 +**(4) Show alarm area**
1429 1429  
1430 -* **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1431 -* **Start angle: **It sets the position where the minimum value is displayed.
1430 +It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color.
1432 1432  
1432 +**(5) Show scale**
1433 +
1434 +It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them.
1435 +
1436 +**(6) Meter angel settings**
1437 +
1438 +1. **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1439 +1. **Start angle: **It sets the position where the minimum value is displayed.
1440 +
1433 1433  **Result**
1434 1434  
1435 1435  When configuration is completed, the object is shown as below picture when HMI is running.
... ... @@ -1438,10 +1438,7 @@