Changes for page 05 Objects

Last modified by Jett on 2025/04/08 13:50

From version 20.1
edited by Stone Wu
on 2022/08/08 14:20
Change comment: There is no comment for this version
To version 17.1
edited by Stone Wu
on 2022/08/05 10:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -183,12 +183,13 @@
183 183  
184 184  **Description**
185 185  
186 +
186 186  (% style="text-align:center" %)
187 187  [[image:6.Objects_html_273aed06eb8f10f9.gif||class="img-thumbnail"]]
188 188  
189 -**Address**: It is for setting specified PLC or HMI bit address。
190 +**(1) Address**: It is for setting specified PLC or HMI bit address。
190 190  
191 -**Hide**
192 +**(2) Hide**
192 192  
193 193  * **Inverted Display: **Display reverse state of the picture and text. *for example, the value of write address is set ON, the OFF mode is displayed.
194 194  * **Blinking: **Blinking while control bit is triggered, the frequency is editable;
... ... @@ -1397,39 +1397,41 @@
1397 1397  
1398 1398  The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1399 1399  
1400 -(% style="text-align:center" %)
1401 -[[image:image-20220805161001-1.jpeg]]
1401 +**Description**
1402 1402  
1403 -**Read address:** Read the value from the set PLC address.
1404 1404  
1405 -**Data format:** It is for data setting. The data format types are as below.
1404 +(% style="text-align:center" %)
1405 +[[image:6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]]
1406 1406  
1407 -* BCD, 32-bit float
1408 -* signed decimal
1409 -* unsigned decimal
1410 -* 32-bit signed decimal
1411 -* 32-bit unsigned decimal
1407 +**(1) Basic**
1412 1412  
1413 -**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.
1409 +1. **Read address:** Read the value from the set PLC address.
1410 +1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal.
1411 +1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal.
1412 +1. **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1413 +1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1414 1414  
1415 -* **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1415 +**(2) Show meter background**
1416 1416  
1417 -**Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1417 +This is for setting meter background, there are four types, you could select it according to needs.
1418 1418  
1419 -**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs.
1419 +**(3) Show pointer**
1420 1420  
1421 -**Show pointer**: When not checked, the pointer is not displayed; When checked, you could set the style and color of pointer.
1421 +You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color.
1422 1422  
1423 -**Show alarm area**: It provides alarm function in meter, you could set the 4 areas, and each area corresponds to a different alarm color.
1423 +**(4) Show alarm area**
1424 1424  
1425 -**Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value.
1425 +It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color.
1426 1426  
1427 -**Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1427 +**(5) Show scale**
1428 1428  
1429 -**Start angle: **It sets the position where the minimum value is displayed.
1429 +It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them.
1430 1430  
1431 -**Position&size:** Set the position of the object in the screen and the size of the object. The object is displayed as square. If the width or the height of the object is changed, the other data will also be changed.
1431 +**(6) Meter angel settings**
1432 1432  
1433 +1. **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1434 +1. **Start angle: **It sets the position where the minimum value is displayed.
1435 +
1433 1433  **Result**
1434 1434  
1435 1435  When configuration is completed, the object is shown as below picture when HMI is running.
... ... @@ -1438,10 +1438,7 @@
1438 1438  [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]]
1439 1439  
1440 1440  
1441 -(% class="box infomessage" %)
1442 -(((
1443 1443  ✎**Note:** For the parameter setting, please refer to "[[text>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HText]]" in "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]".
1444 -)))
1445 1445  
1446 1446  == **Bar** ==
1447 1447  
... ... @@ -1672,44 +1672,39 @@
1672 1672  
1673 1673  Rotation picture can rotate the image at a specified center or rotate it in a certain way. It is determined by the property settings.
1674 1674  
1675 +**Description**
1676 +
1675 1675  (% style="text-align:center" %)
1676 -[[image:image-20220805155253-1.jpeg]]
1678 +[[image:6.Objects_html_e43758e6e4e3e685.gif||class="img-thumbnail"]]
1677 1677  
1680 +**1) Counter-Clockwise**
1678 1678  
1679 -**Position: **Display the position of the rotation picture in the screen.
1682 +It sets the rotation direction of the picture. The default is to rotate clockwise. When checked, the rotation direction is counterclockwise.
1680 1680  
1681 -**Counter-Clockwise: **It sets the rotation direction of the picture. The default is to rotate clockwise. When checked, the rotation direction is counterclockwise.
1684 +**2) Appearance**
1682 1682  
1683 -**Appearance**: It sets picture for object, the picture is selected from Shape.
1686 +It sets picture for object, the picture is selected from Shape.
1684 1684  
1685 -**Data format**
1688 +**3) Data format**
1686 1686  
1687 1687  * **Data format: **It sets data format for [Address]->[Rotation angle].
1688 -** BCD
1689 -** 32-bit float
1690 -** 16-bit signed decimal
1691 -** 16-bit unsigned decimal
1692 -** 32-bit signed decimal
1693 -** 32-bit unsigned decimal
1694 1694  * **Min. angle:** It sets the starting angle of rotation (Valid in auto-rotation mode).
1695 1695  * **Max. angle:** It sets the ending angle of rotation (Valid in auto-rotation mode).
1696 1696  
1697 -**Rotation angle: **the rotating angle is determined by designated address;
1694 +**4) Address**
1698 1698  
1699 -**Rotation center**: It shows the rotation center coordinates;
1696 +**Rotation angle:**the rotating angle is determined by designated address; this mode and auto-rotation mode could not be used at the same time.
1700 1700  
1701 -**Auto-rotation: **Taker the center of the image as the center of the picture when it is rotating.
1698 +**5) Rotation center**
1702 1702  
1703 -**Cycle time: **Object will rotate every cycle time. Unit:100 ms.
1700 +It shows the rotation center coordinates;
1704 1704  
1705 -**Rotation angle:** Object rotates designated angle everytime.
1702 +**6) Auto-rotation**
1706 1706  
1707 -**Return:** Object will be reset to original position after maximum angle reached.
1704 +* **Cycle time: **Object will rotate every cycle time. Unit:100 ms.
1705 +* **Rotation angle:** Object rotates designated angle everytime.
1706 +* **Return:** Object will be reset to original position after maximum angle reached.
1708 1708  
1709 -**Enable auto-spin: **When the address is set to ON, the picture will rotate automatically.
1710 -
1711 -**Hide:** control the hiding status of the object through the status of the control bit address. The hiding mode can be divided into hide when OFF and hide when ON.
1712 -
1713 1713  == **Drop-down List** ==
1714 1714  
1715 1715  Drop-Down list is designed for display the designated state by text, to select the text in the list, the corresponding state will change, and the write address will change to the designated state value.
image-20220805155253-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -47.1 KB
Content
image-20220805161001-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -51.3 KB
Content