... ... @@ -183,12 +183,13 @@
183 183  
184 184  **Description**
185 185  
186 +
186 186  (% style="text-align:center" %)
187 187  [[image:6.Objects_html_273aed06eb8f10f9.gif||class="img-thumbnail"]]
188 188  
189 -**Address**: It is for setting specified PLC or HMI bit address。
190 +**(1) Address**: It is for setting specified PLC or HMI bit address。
190 190  
191 -**Hide**
192 +**(2) Hide**
192 192  
193 193  * **Inverted Display: **Display reverse state of the picture and text. *for example, the value of write address is set ON, the OFF mode is displayed.
194 194  * **Blinking: **Blinking while control bit is triggered, the frequency is editable;
... ... @@ -1397,39 +1397,41 @@
1397 1397  
1398 1398  The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1399 1399  
1400 -(% style="text-align:center" %)
1401 -[[image:image-20220805161001-1.jpeg]]
1401 +**Description**
1402 1402  
1403 -**Read address:** Read the value from the set PLC address.
1404 1404  
1405 -**Data format:** It is for data setting. The data format types are as below.
1404 +(% style="text-align:center" %)
1405 +[[image:6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]]
1406 1406  
1407 -* BCD, 32-bit float
1408 -* signed decimal
1409 -* unsigned decimal
1410 -* 32-bit signed decimal
1411 -* 32-bit unsigned decimal
1407 +**(1) Basic**
1412 1412  
1413 -**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.
1409 +1. **Read address:** Read the value from the set PLC address.
1410 +1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal.
1411 +1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal.
1412 +1. **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1413 +1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1414 1414  
1415 -* **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1415 +**(2) Show meter background**
1416 1416  
1417 -**Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1417 +This is for setting meter background, there are four types, you could select it according to needs.
1418 1418  
1419 -**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs.
1419 +**(3) Show pointer**
1420 1420  
1421 -**Show pointer**: When not checked, the pointer is not displayed; When checked, you could set the style and color of pointer.
1421 +You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color.
1422 1422  
1423 -**Show alarm area**: It provides alarm function in meter, you could set the 4 areas, and each area corresponds to a different alarm color.
1423 +**(4) Show alarm area**
1424 1424  
1425 -**Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value.
1425 +It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color.
1426 1426  
1427 -**Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1427 +**(5) Show scale**
1428 1428  
1429 -**Start angle: **It sets the position where the minimum value is displayed.
1429 +It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them.
1430 1430  
1431 -**Position&size:** Set the position of the object in the screen and the size of the object. The object is displayed as square. If the width or the height of the object is changed, the other data will also be changed.
1431 +**(6) Meter angel settings**
1432 1432  
1433 +1. **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1434 +1. **Start angle: **It sets the position where the minimum value is displayed.
1435 +
1433 1433  **Result**
1434 1434  
1435 1435  When configuration is completed, the object is shown as below picture when HMI is running.
... ... @@ -1438,10 +1438,7 @@
1438 1438  [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]]
1439 1439  
1440 1440  
1441 -(% class="box infomessage" %)
1442 -(((
1443 1443  ✎**Note:** For the parameter setting, please refer to "[[text>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HText]]" in "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]".
1444 -)))
1445 1445  
1446 1446  == **Bar** ==
1447 1447  
image-20220805161001-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -51.3 KB
Content