Changes for page 05 Objects
Last modified by Jett on 2025/04/08 13:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -183,12 +183,13 @@ 183 183 184 184 **Description** 185 185 186 + 186 186 (% style="text-align:center" %) 187 187 [[image:6.Objects_html_273aed06eb8f10f9.gif||class="img-thumbnail"]] 188 188 189 -**Address**: It is for setting specified PLC or HMI bit address。 190 +**(1) Address**: It is for setting specified PLC or HMI bit address。 190 190 191 -**Hide** 192 +**(2) Hide** 192 192 193 193 * **Inverted Display: **Display reverse state of the picture and text. *for example, the value of write address is set ON, the OFF mode is displayed. 194 194 * **Blinking: **Blinking while control bit is triggered, the frequency is editable; ... ... @@ -1397,39 +1397,41 @@ 1397 1397 1398 1398 The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter. 1399 1399 1400 -(% style="text-align:center" %) 1401 -[[image:image-20220805161001-1.jpeg]] 1401 +**Description** 1402 1402 1403 -**Read address:** Read the value from the set PLC address. 1404 1404 1405 -**Data format:** It is for data setting. The data format types are as below. 1404 +(% style="text-align:center" %) 1405 +[[image:6.Objects_html_7b4e0390c9bae4fd.gif||class="img-thumbnail"]] 1406 1406 1407 -* BCD, 32-bit float 1408 -* signed decimal 1409 -* unsigned decimal 1410 -* 32-bit signed decimal 1411 -* 32-bit unsigned decimal 1407 +**(1) Basic** 1412 1412 1413 -**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address. 1409 +1. **Read address:** Read the value from the set PLC address. 1410 +1. **Data format:** It is for data setting. The data format types are: BCD, 32-bit float, signed decimal, unsigned decimal, 32-bit signed decimal and 32-bit unsigned decimal. 1411 +1. **Digits setting:** it means the decimal point position. the decimal point position is effective only when data format is floating and decimal. 1412 +1. **Min angle and max angle:** Data range, if data beyond range will be not inputted. 1413 +1. **Variable limits:** when checked, low limit address and high limit address could be edit showed below; 1414 1414 1415 -* *Minangleandmax angle:** Data range,if databeyond range will be not inputted.1415 +**(2) Show meter background** 1416 1416 1417 - **Variablelimits:**whenchecked,low limit addressandhigh limitaddresscouldbeditshowedbelow;1417 +This is for setting meter background, there are four types, you could select it according to needs. 1418 1418 1419 -**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointermeter to select it according to needs.1419 +**(3) Show pointer** 1420 1420 1421 - **Show pointer**:Whennot checked, thepointer isnotdisplayed;Whenchecked,you could set the styleandcolorofpointer.1421 +You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color. 1422 1422 1423 -**Show alarm area** : It provides alarm function in meter, you could set the 4 areas, and each area corresponds to a different alarm color.1423 +**(4) Show alarm area** 1424 1424 1425 - **Showscale**:Displaythe scale ontheobjecttoobservethevalue.Youneedto set major scale,minorscaleandcalevalue.1425 +It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color. 1426 1426 1427 -** MeterType:** It sets the angel betweenthe maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.1427 +**(5) Show scale** 1428 1428 1429 - **Startangle:**It setsthe positionwheretheminimumvalueisdisplayed.1429 +It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them. 1430 1430 1431 -** Position&size:** Settheposition of theobject in the screenand thesize of the object. The object is displayedassquare. Ifthe width or the height of the object is changed, the other data will also be changed.1431 +**(6) Meter angel settings** 1432 1432 1433 +1. **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1434 +1. **Start angle: **It sets the position where the minimum value is displayed. 1435 + 1433 1433 **Result** 1434 1434 1435 1435 When configuration is completed, the object is shown as below picture when HMI is running. ... ... @@ -1438,10 +1438,7 @@ 1438 1438 [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]] 1439 1439 1440 1440 1441 -(% class="box infomessage" %) 1442 -((( 1443 1443 ✎**Note:** For the parameter setting, please refer to "[[text>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HText]]" in "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 1444 -))) 1445 1445 1446 1446 == **Bar** == 1447 1447
- image-20220805161001-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -51.3 KB - Content