Changes for page 05 Objects
Last modified by Jett on 2025/04/08 13:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -183,12 +183,13 @@ 183 183 184 184 **Description** 185 185 186 + 186 186 (% style="text-align:center" %) 187 187 [[image:6.Objects_html_273aed06eb8f10f9.gif||class="img-thumbnail"]] 188 188 189 -**Address**: It is for setting specified PLC or HMI bit address。 190 +**(1) Address**: It is for setting specified PLC or HMI bit address。 190 190 191 -**Hide** 192 +**(2) Hide** 192 192 193 193 * **Inverted Display: **Display reverse state of the picture and text. *for example, the value of write address is set ON, the OFF mode is displayed. 194 194 * **Blinking: **Blinking while control bit is triggered, the frequency is editable; ... ... @@ -1416,20 +1416,27 @@ 1416 1416 1417 1417 **Variable limits:** when checked, low limit address and high limit address could be edit showed below; 1418 1418 1419 -**Show meter background** : This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs.1420 +**Show meter background** 1420 1420 1421 - **Showpointer**:Whennot checked, thepointeris notdisplayed; When checked, you could set thestyleandcolor ofpointer.1422 +This is for setting meter background, there are four types, you could select it according to needs. 1422 1422 1423 -**Show alarm area**: Itprovides alarm function in meter, you could set the 4 areas, and each area corresponds to a different alarm color.1424 +**Show pointer** 1424 1424 1425 - **Showscale**:Display the scaleonhe objectto observethe value. Youneed tosetmajorscale,minorscale and scalevalue.1426 +You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color. 1426 1426 1427 -** Meter Type:** It sets theangelbetween the maximumand minimum value. It provides 7 kinds of styles, theyare 180°, 210°, 240°, 270°, 300°, 330° and 360°.1428 +**Show alarm area** 1428 1428 1429 - **Startangle:**It setsthe positionwhere theminimumvalueis displayed.1430 +It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color. 1430 1430 1431 -** Position&size:**Set the position of the object in the screen and the size of the object. The object is displayed as square. If thewidthor the height of the object ishanged, the other data will also bechanged.1432 +**Show scale** 1432 1432 1434 +It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them. 1435 + 1436 +**Meter angel settings** 1437 + 1438 +* **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1439 +* **Start angle: **It sets the position where the minimum value is displayed. 1440 + 1433 1433 **Result** 1434 1434 1435 1435 When configuration is completed, the object is shown as below picture when HMI is running.