... ... @@ -183,12 +183,13 @@
183 183  
184 184  **Description**
185 185  
186 +
186 186  (% style="text-align:center" %)
187 187  [[image:6.Objects_html_273aed06eb8f10f9.gif||class="img-thumbnail"]]
188 188  
189 -**Address**: It is for setting specified PLC or HMI bit address。
190 +**(1) Address**: It is for setting specified PLC or HMI bit address。
190 190  
191 -**Hide**
192 +**(2) Hide**
192 192  
193 193  * **Inverted Display: **Display reverse state of the picture and text. *for example, the value of write address is set ON, the OFF mode is displayed.
194 194  * **Blinking: **Blinking while control bit is triggered, the frequency is editable;
... ... @@ -1418,18 +1418,21 @@
1418 1418  
1419 1419  **Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs.
1420 1420  
1421 -**Show pointer**: When not checked, the pointer is not displayed; When checked, you could set the style and color of pointer.
1422 +**Show pointer**: When not checked, the pointer is not displayed; When checked, there are four styles of pointer meter to select it according to needs. You could select show pointer or not according to need, and it provides two types for pointer and users could select pointer color.
1422 1422  
1423 -**Show alarm area**: It provides alarm function in meter, you could set the 4 areas, and each area corresponds to a different alarm color.
1424 +**Show alarm area**
1424 1424  
1425 -**Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value.
1426 +It provides alarm function in meter, users could set alarm range, users could set the 4 ranges. And each range corresponds to a different alarm color.
1426 1426  
1427 -**Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1428 +**Show scale**
1428 1428  
1429 -**Start angle: **It sets the position where the minimum value is displayed.
1430 +It provides settings for scale on meter, users could select [Major scale] and [Minor scale], and set color for them.
1430 1430  
1431 -**Position&size:** Set the position of the object in the screen and the size of the object. The object is displayed as square. If the width or the height of the object is changed, the other data will also be changed.
1432 +**Meter angel settings**
1432 1432  
1434 +* **Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1435 +* **Start angle: **It sets the position where the minimum value is displayed.
1436 +
1433 1433  **Result**
1434 1434  
1435 1435  When configuration is completed, the object is shown as below picture when HMI is running.