Changes for page 05 Objects
Last modified by Hunter on 2026/07/14 14:46
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (2 modified, 0 added, 3 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.joe - Content
-
... ... @@ -32,13 +32,13 @@ 32 32 33 33 **Display** 34 34 35 -* **Inverted Display: **Display stheobject'sstate image and textinreverse state order.35 +* **Inverted Display: **Display the state picture and text of the object reversely. 36 36 * **Quick Read: **The priority of read and write is higher than any other objects on the same screen. 37 -* **Blink: ** When enabled, the bit switch blinkswhen the specifiedconditionismet;38 -** **Blink when ON: **Blink the bit switchwhen control bit is ON.39 -** **Blink when OFF: **Blink thebit switchwhen control bit is OFF.37 +* **Blink: **Blinking while control bit is triggered; 38 +** **Blink when ON: **Blink when control bit is ON. 39 +** **Blink when OFF: **Blink when control bit is OFF. 40 40 41 -**Minimum hold time: ** Specifiesthe press-and-holddurationrequired for the actiontotake effect.41 +**Minimum hold time: **Only when the time of press and hold the object is greater than the set value, the object function will be executed. 42 42 43 43 **Indirect addressing:** 44 44 ... ... @@ -245,7 +245,7 @@ 245 245 * **Decrease:** Decrease Operand value for each time the switch is triggered. 246 246 * **High/Low limit:** The value will be not able to change when the value reaches limits. 247 247 248 -**Min.Hold Time: **Specifiestheminimumintervalbetweenrepeatedtriggers.248 +**Min.Hold Time:**After continuously clicking the button for a period of time, the button will perform operations continuously 249 249 250 250 (% class="box infomessage" %) 251 251 ((( ... ... @@ -267,7 +267,7 @@ 267 267 **Address** 268 268 269 269 * **Read address:** Read the value from object display. 270 -* **States count: ** Specifiesthenumberofstatesforthe specifiedwordaddress, range: 1-256.270 +* **States count: **Total status number for current word address, which could change the state value according to different status in button [State values], range: 1-256. 271 271 * **State with value out of range**: When the value of the read address is not on the range of states' value, it will cause no corresponding status number is displayed. There are two modes for process when the value is out of range. 272 272 * **Hide**: Hide the object when the value is out of range; 273 273 * **Show state**: Specify a status when the value is out of range, for example the total states is 6(range from state No.0~~No.5), but the read value is 6, at this moment the object will show the state No.0 if selected item of show state is No.0; ... ... @@ -286,15 +286,15 @@ 286 286 **Transform state** 287 287 288 288 * **Quick Read: **The priority of read and write is higher than any other objects on the same screen. 289 -* **Auto transforms:** Thelampautomaticallyswitches between states.289 +* **Auto transforms:** Object switch states automatically 290 290 291 291 (% style="text-align:center" %) 292 292 [[image:6.Objects_html_b643c9a6a4bd6919.gif||class="img-thumbnail"]] 293 293 294 -* **Trigger to transform: ** Specifies the trigger conditionforAutoTransform.294 +* **Trigger to transform: **Trigger condition of auto transform 295 295 * **Auto return:** Return to the initial state after reaching the final state; 296 296 * **Time of transform:** Set the interval of transform between two states; 297 -* **Dynamic time: **Specifiestheaddressusedtocontroltheautomaticstateswitching interval. If the value in address is 10, then the frequency of automatic switching state is 10*100ms = 1s.297 +* **Dynamic interval: **Set the dynamic interval of transform between two states. If the value in address is 10, then the frequency of automatic switching state is 10*100ms = 1s. 298 298 299 299 **Manual** 300 300 ... ... @@ -301,11 +301,10 @@ 301 301 (% style="text-align:center" %) 302 302 [[image:6.Objects_html_a8b6636bd862369c.gif||class="img-thumbnail"]] 303 303 304 -* **S tate set: **Set statevalue towordaddress(according to the operate state selection) when click thelampobject.304 +* **Set state: **Set a constant value to address(according to the operate state selection) when click the object. 305 305 * **State increase: **Increase the address value by one step when click the object, the upper limit is depends on the Last state selection. 306 306 * **State decrease:** Decrease the address value by one step when click the object, the lower limit is depends on the Last state selection.. 307 -* **Last state: **The final state after the change; 308 -* **Return to state:** The word lamp returns to the selected state option when click the final state. 307 +* **Last state: **The upper limit or lower limit(Final state) of state increase/decrease; 309 309 310 310 (% class="box infomessage" %) 311 311 ((( ... ... @@ -339,8 +339,8 @@ 339 339 (% style="text-align:center" %) 340 340 [[image:6.Objects_html_31c4ad387507a16d.gif||class="img-thumbnail"]] 341 341 342 -* **Screen No: ** The screennumber to jump to, it could not be subscreen;343 -* **Open sub screen: ** The sub-screen numbertopop up, default position is (0, 0), this is the coordinates of the top left corner of the screen;341 +* **Screen No: **Switch to the selected screen, it could not be subscreen; 342 +* **Open sub screen: **Pop-up selected sub screen, and set sub screen position, default position is (0, 0), this is the coordinates of the top left corner of the screen; 344 344 345 345 (% style="text-align:center" %) 346 346 [[image:6.Objects_html_8b9a9cc4cb589d5b.gif||class="img-thumbnail"]] ... ... @@ -629,7 +629,7 @@ 629 629 * **Read Address:** The data from designated address will be displayed. 630 630 * **Input: **Enable input function and "Write Address" configuration. 631 631 * **Same read-write address:** Configure "Write Address" is the same as "Read Address". 632 -* **Read DWord: **Read one bytefromeachtwo-byteunit.For example,thestring "abcd" is displayed as "ac".631 +* **Read DWord: **Read the address data at double byte format. 633 633 * **Write address: **Write data to designated address. The address could be different "Read Address". 634 634 * **Keypad:** Built-in character keyboard input(Screen No.1001) could allow input a~~z, A~~Z, 0~~9. 635 635 * **Note**: After the keypad is opened, the content of note will be input into special register HUW1402. The maximum length allowed for the note is 63 characters. ... ... @@ -1409,7 +1409,7 @@ 1409 1409 1410 1410 (% class="box infomessage" %) 1411 1411 ((( 1412 -Only ig series HMI and R series V-boxhave this function.1411 +Only ig series have this function. 1413 1413 ))) 1414 1414 1415 1415 The recipe record display component displays recipe data in a table format and can perform operations such as adding, deleting, modifying, uploading, downloading, importing and exporting the recipe. ... ... @@ -1437,82 +1437,21 @@ 1437 1437 1438 1438 **Introduction:** Query all alarm records for a specific group number and display them in a table format in chronological order. The query time period can be dynamically set on HMI, and the display is saved after power-off. 1439 1439 1440 -(% class="box infomessage" %) 1441 -((( 1442 -Note: 1443 1443 1.Alarm Record in versions **10.0** and above are referred to as the "New Alarm Record," while those in versions below 10.0 are referred to as the "Old Alarm Record." 1440 + 1444 1444 2.Differences between New Alarm Record and Old Alarm Record: 1442 + 1445 1445 ① Clearer page configuration, divided into three main pages: "Basic," "Graphics," and "Alarm Properties." 1444 + 1446 1446 ② Appearance settings offer more style settings. 1446 + 1447 1447 ③ Added alarm property settings, allowing to change the color when confirming. 1448 + 1448 1448 ④ The ability to configure function addresses and query time periods in the project configuration has been removed. Instead, directly query and filter time periods and group numbers at runtime. 1450 + 1449 1449 ⑤Added horizontal and vertical scroll bars for easier screen navigation. 1450 -))) 1451 1451 1452 -**General:** 1453 1453 1454 -**1.Alarm Type :** There are three alarm modes including Current alarm record, History alarm record and Alarm event statistics. 1455 - 1456 -**(1) Current alarm records:** Only the current alarm record will be displayed. If the alarm is triggered, the record will disappear. 1457 - 1458 -**(2) Historical alarm records: **All alarm and alarm trigger records will be displayed one by one. 1459 - 1460 -**(3) Alarm event statistics:** Only one record for the same alarm address will be displayed. 1461 - 1462 -**2.Group number range**: The group number range of the alarm records to be displayed. Alarm records that are not in this range will not be displayed. 1463 - 1464 -**3.Time setting**: Select the display format of time and date. 1465 - 1466 - 1467 -(% style="text-align:center" %) 1468 -[[image:屏幕截图 2025-09-05 164650.png]] 1469 - 1470 -**Graphic:** 1471 - 1472 -**1.Style Selection:** Select a system-provided style from the Style Selection menu, or select "Custom" to customize the colors. 1473 - 1474 -(% class="box infomessage" %) 1475 -((( 1476 -Note: If select a system-provided style, the table color can not be changed. 1477 -))) 1478 - 1479 -**2.Cell format:** Includes two options: "Adaptive" and "Custom" 1480 - 1481 -**①Adaptive:** Cells automatically adjust size based on text length. 1482 - 1483 -**②Custom: **Manually set column widths and row heights for all cells. 1484 - 1485 -(% style="text-align:center" %) 1486 -[[image:屏幕截图 2025-09-05 164729.png]] 1487 - 1488 -**Alaem Properties** 1489 - 1490 -**1.Alarm Display Status** 1491 - 1492 -**(1) Confirm:** Set the text and background color for confirming an alarm record. 1493 - 1494 -(% class="box infomessage" %) 1495 -((( 1496 -Note: "Confirm" must be selected for the alarm to display successfully. 1497 -))) 1498 - 1499 -**(2)Back to normal:** Set the text and background color for the record when the alarm record returns to normal. 1500 - 1501 -**2. Sorting** 1502 - 1503 -**(1)Method:** Indicates the field to sort by. The default is time. 1504 - 1505 -**(2) Order:** Indicates the order to sort by. The default is descending order. 1506 - 1507 -**(3) Confirm: **Sets the method for confirming an alarm record and the write address. 1508 - 1509 -**① Confirmation Method: **The method for confirming an alarm record. There are three methods including single-click, double-click, and long press for 3 seconds. The default is single-click. 1510 - 1511 -**②Write Address:** The write address to be written during confirmation. Confirming will reset the contents of the write address to 0. 1512 - 1513 -(% style="text-align:center" %) 1514 -[[image:123.png]] 1515 - 1516 1516 == **Meter** == 1517 1517 1518 1518 (% style="text-align:center" %) ... ... @@ -2109,6 +2109,8 @@ 2109 2109 If the "Camera Search Module" is not enabled, you need to enter the camera information manually: user name, password, device serial number (S/N), which can be obtained from the label on the camera body. 2110 2110 ))) 2111 2111 2050 +(% style="text-align:center" %) 2051 +[[image:图片1.png]] 2112 2112 2113 2113 2114 2114 * (((
- 123.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.1 KB - Content
- 图片2.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 28.7 KB1 +17.1 KB - Content
- 图片3.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 62.6KB1 +1.7 KB - Content
- 屏幕截图 2025-09-05 164650.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.7 KB - Content
- 屏幕截图 2025-09-05 164729.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.joe - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.4 KB - Content