Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1400,11 +1400,11 @@ 1400 1400 * 32-bit signed decimal 1401 1401 * 32-bit unsigned decimal 1402 1402 1403 -**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the maximum and minimum value be with a decimal point, and other data formats can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.1403 +**Digits setting:** Set directly the maximum and the minimum. Only when the floating point number is selected, can the maximum and minimum value be with a decimal point, and other data formats can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address. 1404 1404 1405 1405 * **Min angle and max angle:** Data range, if data beyond range will be not inputted. 1406 1406 1407 -**Variable limits:** when checked, low limit address and high limit address could be edit showed below;1407 +**Variable limits:** When checked, low limit address and high limit address could be edit showed below; 1408 1408 1409 1409 **Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select according to needs. 1410 1410 ... ... @@ -1414,7 +1414,7 @@ 1414 1414 1415 1415 **Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value. 1416 1416 1417 -**Meter Type:** It sets the ang el between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.1417 +**Meter Type:** It sets the angle between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1418 1418 1419 1419 **Start angle: **It sets the position where the minimum value is displayed. 1420 1420 ... ... @@ -1605,13 +1605,10 @@ 1605 1605 1606 1606 == **QR Code** == 1607 1607 1608 -**Introduction** 1609 - 1610 1610 It is similar to the universal QR code. You could scan this object to get the connection or content, but it provides content settings for QR code. 1611 1611 1612 1612 **Description** 1613 1613 1614 - 1615 1615 (% style="text-align:center" %) 1616 1616 [[image:6.Objects_html_4cf155075ac97d16.gif||class="img-thumbnail"]] 1617 1617 ... ... @@ -1623,7 +1623,7 @@ 1623 1623 **✎Note:** 1624 1624 1625 1625 * HMI machine ID address: HSW10494 ~~ HSW10558. 1626 -* So if user want to use QR code to display machine ID in project screen, please check "Variable QR", and set address is HSW10494.1623 +* So if user want to use QR code to display machine ID on project screen, please check "Variable QR", and set address is HSW10494. 1627 1627 * When scanning the QR code by APP to monitor HMI, the default access password is 888888. 1628 1628 1629 1629 == **Picture** == ... ... @@ -1649,9 +1649,9 @@ 1649 1649 1650 1650 This is advanced function of picture object; user can change display picture when HMI is running. The supported formats are bmp, jpg, png, jpeg. This feature is unavailable for offline and online simulation. 1651 1651 1652 -1. **Root: **Set the save location of the picture,which can be set to U disk,SD card,but could not be set to Flash. 1649 +1. **Root: **Set the save location of the picture, which can be set to U disk,SD card,but could not be set to Flash. 1653 1653 1. **Folder: **Set the name of the folder where the picture is located.The folder name can be up to 31 characters. (Note:The picture must be stored in the U disk folder and cannot be stored in the root directory of the U disk.) 1654 -1. **File address: **16 consecutive addressesenter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed. 1651 +1. **File address: **16 consecutive addresses enter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed. 1655 1655 1656 1656 ✎**Note:** 1657 1657 ... ... @@ -1684,7 +1684,7 @@ 1684 1684 * **Min. angle:** It sets the starting angle of rotation (Valid in auto-rotation mode). 1685 1685 * **Max. angle:** It sets the ending angle of rotation (Valid in auto-rotation mode). 1686 1686 1687 -**Rotation angle: ** the rotating angle is determined by designated address;1684 +**Rotation angle: **The rotating angle is determined by designated address; 1688 1688 1689 1689 **Rotation center**: It shows the rotation center coordinates; 1690 1690 ... ... @@ -1698,7 +1698,7 @@ 1698 1698 1699 1699 **Enable auto-spin: **When the address is set to ON, the picture will rotate automatically. 1700 1700 1701 -**Hide:** control the hiding status of the object through the status of the control bit address. The hiding mode can be divided into hide when OFF and hide when ON.1698 +**Hide:** Control the hiding status of the object through the status of the control bit address. The hiding mode can be divided into hide when OFF and hide when ON. 1702 1702 1703 1703 == **Drop-down List** == 1704 1704 ... ... @@ -1714,18 +1714,18 @@ 1714 1714 **1) Edit** 1715 1715 1716 1716 1. **Read Address:** The data from designated address will be displayed. 1717 -1. **Same read-write address:** Configure "Write Address" is the same as "Read Address".1718 -1. **Write Address: **Write data to designated address. The address can be different "Read Address". 1714 +1. **Same read-write address:** Configure "Write Address" as the same as "Read Address". 1715 +1. **Write Address: **Write data to designated address. The address can be different from "Read Address". 1719 1719 1720 1720 **2) Format** 1721 1721 1722 -Set data format for object, it provides 16-bit unsigned decimal,16-bit BCD, 16-bit unsigned decimal, 32-bit BCD, 32-bit unsigned decimal and 32-bit unsigned decimal. 1719 +Set data format for object, it provides 16-bit unsigned decimal,16-bit BCD, 16-bit unsigned decimal, 32-bit BCD, 32-bit unsigned decimal, and 32-bit unsigned decimal. 1723 1723 1724 1724 **3) State count** 1725 1725 1726 1726 It could set the total number to display in the drop-list and supports up to 128 states (1 to 128). The default value of state is corresponding to the number of states. (State 1 corresponding to value 1). You can also click "state values" to set it according to your needs. 1727 1727 1728 -**State value: ** Youcan set different values to correspond to different states, the setting window as below figure shows.1725 +**State value: **User can set different values to correspond to different states, the setting window as below figure shows. 1729 1729 1730 1730 (% style="text-align:center" %) 1731 1731 [[image:6.Objects_html_da9a6696f320b427.gif||class="img-thumbnail"]] ... ... @@ -1769,12 +1769,12 @@ 1769 1769 1770 1770 **3) Read state text from address** 1771 1771 1772 -1. **Text start address: ** the first address of occupied multiple consecutive addresses. Address length: [Text length/2] *[state number +1].1769 +1. **Text start address: **The first address of occupied multiple consecutive addresses. Address length: [Text length/2] *[state number +1]. 1773 1773 1774 1774 * For example: 10 states, the address length= (10/2) *(10+1) =55. It set HDW100 as start address, so the HDW100-HDW104 stores the currently selected text content, the HDW105-HDW109 displays the text in the first state, the HDW110-HDW114 displays the second, and so on. 1775 1775 1776 1776 (% start="2" %) 1777 -1. **Refresh:**The drop-down list status value is updated according to the text address content.The drop-down list is not updated immediately, when the data in the text address change is completed, only the refresh is triggered, it will update. 1774 +1. **Refresh: **The drop-down list status value is updated according to the text address content. The drop-down list is not updated immediately, when the data in the text address change is completed, only the refresh is triggered, it will update. 1778 1778 1779 1779 == **Camera display** == 1780 1780 ... ... @@ -1786,6 +1786,8 @@ 1786 1786 1787 1787 === **IP Camera** === 1788 1788 1786 +**(1) General** 1787 + 1789 1789 (% style="text-align:center" %) 1790 1790 [[image:6.Objects_html_2bc22bd50bf65eb.gif||class="img-thumbnail"]] 1791 1791 ... ... @@ -2195,7 +2195,7 @@ 2195 2195 The camera configured via ip only supports, turn on, turn off, screenshot basic functions. 2196 2196 ))) 2197 2197 2198 -**EZVIZ Cloud Desc irption**2197 +**EZVIZ Cloud Description** 2199 2199 2200 2200 (% style="text-align:center" %) 2201 2201 [[image:企业微信截图_1673081149790.png]] ... ... @@ -2301,23 +2301,23 @@ 2301 2301 |=(% style="width: 129px;" %)60020|(% style="width:366px" %)Unsupport this command|(% style="width:531px" %)Confirm the device whether supports this operation or not 2302 2302 2303 2303 (% class="wikigeneratedid" %) 2304 -**Default Configuration**:Enable the default configuration, the initialization of the EZVIZ cloud camera display components will use the default configuration for binding, the screen can also be modified through the function address configuration information; do not enable the default configuration, the default initial configuration of the EZVIZ cloud camera display components are empty. 2303 +**Default Configuration**: Enable the default configuration, the initialization of the EZVIZ cloud camera display components will use the default configuration for binding, the screen can also be modified through the function address configuration information; do not enable the default configuration, the default initial configuration of the EZVIZ cloud camera display components are empty. 2305 2305 2306 2306 **In the default configuration, the following are required:** 2307 2307 2308 -**AppKey**:EZVIZ cloud application information AppKey, up to 32 characters in length, only letters and numbers can be entered, which can be obtained through the EZVIZ cloud open platform. 2309 -**Secret**:EZVIZ cloud application information Secret, up to 32 characters in length, only letters and numbers can be entered, available through the EZVIZ cloud open platform. 2310 -**Channel number**:EZVIZ cloud device source channel number, 1~~65535, no special modification, generally defaulted to 1, which can be obtained by viewing the EZVIZ cloud client software. 2307 +**AppKey**: EZVIZ cloud application information AppKey, up to 32 characters in length, only letters and numbers can be entered, which can be obtained through the EZVIZ cloud open platform. 2308 +**Secret**: EZVIZ cloud application information Secret, up to 32 characters in length, only letters and numbers can be entered, available through the EZVIZ cloud open platform. 2309 +**Channel number**: EZVIZ cloud device source channel number, 1~~65535, no special modification, generally defaulted to 1, which can be obtained by viewing the EZVIZ cloud client software. 2311 2311 2312 -**S/N:**EZVIZ cloud device serial number, 0 to 80 characters in length, only letters, numbers and "-" can be entered, which can be obtained through the device information. 2311 +**S/N: **EZVIZ cloud device serial number, 0 to 80 characters in length, only letters, numbers and "-" can be entered, which can be obtained through the device information. 2313 2313 2314 2314 2315 2315 **In the default configuration, the following are optional:** 2316 2316 2317 -**IP**:EZVIZ cloud device IP, which can be obtained by viewing the EZVIZ cloud client software. 2316 +**IP**: EZVIZ cloud device IP, which can be obtained by viewing the EZVIZ cloud client software. 2318 2318 2319 -**RTSP Port**:EZVIZ cloud device source rtsp port number, range 0~~65535, no special modification, generally default to 554, can be obtained by viewing the EZVIZ cloud client software. 2320 -**Verification Code**:EZVIZ cloud device authentication code, up to 32 characters in length, obtainable through device information. 2318 +**RTSP Port**: EZVIZ cloud device source rtsp port number, range 0~~65535, no special modification, generally default to 554, can be obtained by viewing the EZVIZ cloud client software. 2319 +**Verification Code**: EZVIZ cloud device authentication code, up to 32 characters in length, obtainable through device information. 2321 2321 2322 2322 {{info}} 2323 2323 **✎Note: **The required content in the configuration only supports remote monitoring when the camera screen can be displayed, if there is a demand for the screen side can also display the camera screen, user need to fill in the optional content in the configuration. ... ... @@ -2325,6 +2325,8 @@ 2325 2325 2326 2326 === **USB Camera** === 2327 2327 2327 +**(1) General** 2328 + 2328 2328 (% style="text-align:center" %) 2329 2329 [[image:6.Objects_html_6d926ea40f8267c.gif||class="img-thumbnail"]] 2330 2330 ... ... @@ -2341,7 +2341,7 @@ 2341 2341 |(% style="width:144px" %)1|(% style="width:700px" %)Enable the screenshot function 2342 2342 |(% style="width:144px" %)2|(% style="width:700px" %)refresh camera display object 2343 2343 2344 -**Camera state: **It shows the current camera states. Itoccupies a word address. Different value means different operations, as below table shows: 2345 +**Camera state: **It shows the current camera states. It occupies a word address. Different value means different operations, as below table shows: 2345 2345 2346 2346 (% class="table-bordered" %) 2347 2347 |=**Value**|=**Operation** ... ... @@ -2362,11 +2362,11 @@ 2362 2362 2363 2363 The current screenshots are only allowed on the SD card. When the SD card does not exist the system will cache the latest 10 screenshots. 2364 2364 2365 -**Picture name: **The name of the image is controlled by the address.The length of the file name is limited to 64 words. If the image name address is not set, it will be named according to the time and displayed as [YYYYMMDDHHMMSS.bmp] and screenshot format is [.bmp]. 2366 +**Picture name: **The name of the image is controlled by the address. The length of the file name is limited to 64 words. If the image name address is not set, it will be named according to the time and displayed as [YYYYMMDDHHMMSS.bmp] and screenshot format is [.bmp]. 2366 2366 2367 2367 **4) Global screenshot** 2368 2368 2369 -If this function is enable, camera display object can perform the screenshot operation when HMI is running and save it as a .BMP image. 2370 +If this function is enabled, camera display object can perform the screenshot operation when HMI is running and save it as a . BMP image. 2370 2370 2371 2371 If this function is disabled, camera display object only performs the screenshot operation when it is displayed on screen. 2372 2372 ... ... @@ -2376,15 +2376,15 @@ 2376 2376 2377 2377 **6) Use resolution size** 2378 2378 2379 -Coordinate displays the object location in the screen, and size is the length and width of the object.2380 +Coordinate displays the object location on the screen, and size is the length and width of the object. 2380 2380 2381 2381 **✎Note:** 2382 2382 2383 2383 * When using USB camera, HD USB camera is not recommended, which is limited by the resolution displayed by HMI itself. 2384 -* When HMI is displayed horizontally, the USB camera screen displays normally.If select vertical display, USB camera can't display normally. (USB camera can only display normally when the display Angle of HMI is 0.) 2385 +* When HMI is displayed horizontally, the USB camera screen displays normally. If select vertical display, USB camera can't display normally. (USB camera can only display normally when the display Angle of HMI is 0.) 2385 2385 * One HMI is only allowed to connect with one USB camera device. There is only one USB camera display part in the whole project screen, and the camera display part is not allowed to be placed on the public screen (1002: common Windows). 2386 2386 * Sometimes the USB camera may lose the image because of the influence in the field, then we suggest to PI9000 HMI and the recommended USB camera model. 2387 -* All below USB camera model have been tested by WECON to ensure thecompatibility.2388 +* All below USB camera model have been tested by WECON to ensure compatibility. 2388 2388 * Currently, only PI8000 and PI9000 series support the USB camera function. Recommended USB cameras include: 2389 2389 ** REB-USB 100W07M (supports 720p) 2390 2390 ** WX152HD (supports 720p) ... ... @@ -2393,8 +2393,6 @@ 2393 2393 2394 2394 == **Camera control** == 2395 2395 2396 -**Introduction** 2397 - 2398 2398 This is for control camera; this object need to be used with camera display object. 2399 2399 2400 2400 **Description**