Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1404,7 +1404,7 @@ 1404 1404 1405 1405 * **Min angle and max angle:** Data range, if data beyond range will be not inputted. 1406 1406 1407 -**Variable limits:** when checked, low limit address and high limit address could be edit showed below;1407 +**Variable limits:** When checked, low limit address and high limit address could be edit showed below; 1408 1408 1409 1409 **Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select according to needs. 1410 1410 ... ... @@ -1414,7 +1414,7 @@ 1414 1414 1415 1415 **Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value. 1416 1416 1417 -**Meter Type:** It sets the ang el between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.1417 +**Meter Type:** It sets the angle between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1418 1418 1419 1419 **Start angle: **It sets the position where the minimum value is displayed. 1420 1420 ... ... @@ -1605,13 +1605,10 @@ 1605 1605 1606 1606 == **QR Code** == 1607 1607 1608 -**Introduction** 1609 - 1610 1610 It is similar to the universal QR code. You could scan this object to get the connection or content, but it provides content settings for QR code. 1611 1611 1612 1612 **Description** 1613 1613 1614 - 1615 1615 (% style="text-align:center" %) 1616 1616 [[image:6.Objects_html_4cf155075ac97d16.gif||class="img-thumbnail"]] 1617 1617 ... ... @@ -1623,7 +1623,7 @@ 1623 1623 **✎Note:** 1624 1624 1625 1625 * HMI machine ID address: HSW10494 ~~ HSW10558. 1626 -* So if user want to use QR code to display machine ID in project screen, please check "Variable QR", and set address is HSW10494.1623 +* So if user want to use QR code to display machine ID on project screen, please check "Variable QR", and set address is HSW10494. 1627 1627 * When scanning the QR code by APP to monitor HMI, the default access password is 888888. 1628 1628 1629 1629 == **Picture** == ... ... @@ -1649,9 +1649,9 @@ 1649 1649 1650 1650 This is advanced function of picture object; user can change display picture when HMI is running. The supported formats are bmp, jpg, png, jpeg. This feature is unavailable for offline and online simulation. 1651 1651 1652 -1. **Root: **Set the save location of the picture,which can be set to U disk,SD card,but could not be set to Flash. 1649 +1. **Root: **Set the save location of the picture, which can be set to U disk,SD card,but could not be set to Flash. 1653 1653 1. **Folder: **Set the name of the folder where the picture is located.The folder name can be up to 31 characters. (Note:The picture must be stored in the U disk folder and cannot be stored in the root directory of the U disk.) 1654 -1. **File address: **16 consecutive addressesenter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed. 1651 +1. **File address: **16 consecutive addresses enter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed. 1655 1655 1656 1656 ✎**Note:** 1657 1657 ... ... @@ -1684,7 +1684,7 @@ 1684 1684 * **Min. angle:** It sets the starting angle of rotation (Valid in auto-rotation mode). 1685 1685 * **Max. angle:** It sets the ending angle of rotation (Valid in auto-rotation mode). 1686 1686 1687 -**Rotation angle: ** the rotating angle is determined by designated address;1684 +**Rotation angle: **The rotating angle is determined by designated address; 1688 1688 1689 1689 **Rotation center**: It shows the rotation center coordinates; 1690 1690 ... ... @@ -1698,7 +1698,7 @@ 1698 1698 1699 1699 **Enable auto-spin: **When the address is set to ON, the picture will rotate automatically. 1700 1700 1701 -**Hide:** control the hiding status of the object through the status of the control bit address. The hiding mode can be divided into hide when OFF and hide when ON.1698 +**Hide:** Control the hiding status of the object through the status of the control bit address. The hiding mode can be divided into hide when OFF and hide when ON. 1702 1702 1703 1703 == **Drop-down List** == 1704 1704 ... ... @@ -1714,18 +1714,18 @@ 1714 1714 **1) Edit** 1715 1715 1716 1716 1. **Read Address:** The data from designated address will be displayed. 1717 -1. **Same read-write address:** Configure "Write Address" is the same as "Read Address".1718 -1. **Write Address: **Write data to designated address. The address can be different "Read Address". 1714 +1. **Same read-write address:** Configure "Write Address" as the same as "Read Address". 1715 +1. **Write Address: **Write data to designated address. The address can be different from "Read Address". 1719 1719 1720 1720 **2) Format** 1721 1721 1722 -Set data format for object, it provides 16-bit unsigned decimal,16-bit BCD, 16-bit unsigned decimal, 32-bit BCD, 32-bit unsigned decimal and 32-bit unsigned decimal. 1719 +Set data format for object, it provides 16-bit unsigned decimal,16-bit BCD, 16-bit unsigned decimal, 32-bit BCD, 32-bit unsigned decimal, and 32-bit unsigned decimal. 1723 1723 1724 1724 **3) State count** 1725 1725 1726 1726 It could set the total number to display in the drop-list and supports up to 128 states (1 to 128). The default value of state is corresponding to the number of states. (State 1 corresponding to value 1). You can also click "state values" to set it according to your needs. 1727 1727 1728 -**State value: ** Youcan set different values to correspond to different states, the setting window as below figure shows.1725 +**State value: **User can set different values to correspond to different states, the setting window as below figure shows. 1729 1729 1730 1730 (% style="text-align:center" %) 1731 1731 [[image:6.Objects_html_da9a6696f320b427.gif||class="img-thumbnail"]]