Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1400,11 +1400,11 @@ 1400 1400 * 32-bit signed decimal 1401 1401 * 32-bit unsigned decimal 1402 1402 1403 -**Digits setting:** Set directly the maximum and the minimum. Only when the floating point number is selected, can the maximum and minimum value be with a decimal point, and other data formats can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.1403 +**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the maximum and minimum value be with a decimal point, and other data formats can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address. 1404 1404 1405 1405 * **Min angle and max angle:** Data range, if data beyond range will be not inputted. 1406 1406 1407 -**Variable limits:** When checked, low limit address and high limit address could be edit showed below;1407 +**Variable limits:** when checked, low limit address and high limit address could be edit showed below; 1408 1408 1409 1409 **Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select according to needs. 1410 1410 ... ... @@ -1414,7 +1414,7 @@ 1414 1414 1415 1415 **Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value. 1416 1416 1417 -**Meter Type:** It sets the ang le between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.1417 +**Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°. 1418 1418 1419 1419 **Start angle: **It sets the position where the minimum value is displayed. 1420 1420 ... ... @@ -1605,10 +1605,13 @@ 1605 1605 1606 1606 == **QR Code** == 1607 1607 1608 +**Introduction** 1609 + 1608 1608 It is similar to the universal QR code. You could scan this object to get the connection or content, but it provides content settings for QR code. 1609 1609 1610 1610 **Description** 1611 1611 1614 + 1612 1612 (% style="text-align:center" %) 1613 1613 [[image:6.Objects_html_4cf155075ac97d16.gif||class="img-thumbnail"]] 1614 1614 ... ... @@ -1620,7 +1620,7 @@ 1620 1620 **✎Note:** 1621 1621 1622 1622 * HMI machine ID address: HSW10494 ~~ HSW10558. 1623 -* So if user want to use QR code to display machine ID on project screen, please check "Variable QR", and set address is HSW10494.1626 +* So if user want to use QR code to display machine ID in project screen, please check "Variable QR", and set address is HSW10494. 1624 1624 * When scanning the QR code by APP to monitor HMI, the default access password is 888888. 1625 1625 1626 1626 == **Picture** ==