Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1783,6 +1783,8 @@ 1783 1783 1784 1784 === **IP Camera** === 1785 1785 1786 +**(1) General** 1787 + 1786 1786 (% style="text-align:center" %) 1787 1787 [[image:6.Objects_html_2bc22bd50bf65eb.gif||class="img-thumbnail"]] 1788 1788 ... ... @@ -2192,7 +2192,7 @@ 2192 2192 The camera configured via ip only supports, turn on, turn off, screenshot basic functions. 2193 2193 ))) 2194 2194 2195 -**EZVIZ Cloud Desc irption**2197 +**EZVIZ Cloud Description** 2196 2196 2197 2197 (% style="text-align:center" %) 2198 2198 [[image:企业微信截图_1673081149790.png]] ... ... @@ -2298,23 +2298,23 @@ 2298 2298 |=(% style="width: 129px;" %)60020|(% style="width:366px" %)Unsupport this command|(% style="width:531px" %)Confirm the device whether supports this operation or not 2299 2299 2300 2300 (% class="wikigeneratedid" %) 2301 -**Default Configuration**:Enable the default configuration, the initialization of the EZVIZ cloud camera display components will use the default configuration for binding, the screen can also be modified through the function address configuration information; do not enable the default configuration, the default initial configuration of the EZVIZ cloud camera display components are empty. 2303 +**Default Configuration**: Enable the default configuration, the initialization of the EZVIZ cloud camera display components will use the default configuration for binding, the screen can also be modified through the function address configuration information; do not enable the default configuration, the default initial configuration of the EZVIZ cloud camera display components are empty. 2302 2302 2303 2303 **In the default configuration, the following are required:** 2304 2304 2305 -**AppKey**:EZVIZ cloud application information AppKey, up to 32 characters in length, only letters and numbers can be entered, which can be obtained through the EZVIZ cloud open platform. 2306 -**Secret**:EZVIZ cloud application information Secret, up to 32 characters in length, only letters and numbers can be entered, available through the EZVIZ cloud open platform. 2307 -**Channel number**:EZVIZ cloud device source channel number, 1~~65535, no special modification, generally defaulted to 1, which can be obtained by viewing the EZVIZ cloud client software. 2307 +**AppKey**: EZVIZ cloud application information AppKey, up to 32 characters in length, only letters and numbers can be entered, which can be obtained through the EZVIZ cloud open platform. 2308 +**Secret**: EZVIZ cloud application information Secret, up to 32 characters in length, only letters and numbers can be entered, available through the EZVIZ cloud open platform. 2309 +**Channel number**: EZVIZ cloud device source channel number, 1~~65535, no special modification, generally defaulted to 1, which can be obtained by viewing the EZVIZ cloud client software. 2308 2308 2309 -**S/N:**EZVIZ cloud device serial number, 0 to 80 characters in length, only letters, numbers and "-" can be entered, which can be obtained through the device information. 2311 +**S/N: **EZVIZ cloud device serial number, 0 to 80 characters in length, only letters, numbers and "-" can be entered, which can be obtained through the device information. 2310 2310 2311 2311 2312 2312 **In the default configuration, the following are optional:** 2313 2313 2314 -**IP**:EZVIZ cloud device IP, which can be obtained by viewing the EZVIZ cloud client software. 2316 +**IP**: EZVIZ cloud device IP, which can be obtained by viewing the EZVIZ cloud client software. 2315 2315 2316 -**RTSP Port**:EZVIZ cloud device source rtsp port number, range 0~~65535, no special modification, generally default to 554, can be obtained by viewing the EZVIZ cloud client software. 2317 -**Verification Code**:EZVIZ cloud device authentication code, up to 32 characters in length, obtainable through device information. 2318 +**RTSP Port**: EZVIZ cloud device source rtsp port number, range 0~~65535, no special modification, generally default to 554, can be obtained by viewing the EZVIZ cloud client software. 2319 +**Verification Code**: EZVIZ cloud device authentication code, up to 32 characters in length, obtainable through device information. 2318 2318 2319 2319 {{info}} 2320 2320 **✎Note: **The required content in the configuration only supports remote monitoring when the camera screen can be displayed, if there is a demand for the screen side can also display the camera screen, user need to fill in the optional content in the configuration. ... ... @@ -2322,6 +2322,8 @@ 2322 2322 2323 2323 === **USB Camera** === 2324 2324 2327 +**(1) General** 2328 + 2325 2325 (% style="text-align:center" %) 2326 2326 [[image:6.Objects_html_6d926ea40f8267c.gif||class="img-thumbnail"]] 2327 2327 ... ... @@ -2338,7 +2338,7 @@ 2338 2338 |(% style="width:144px" %)1|(% style="width:700px" %)Enable the screenshot function 2339 2339 |(% style="width:144px" %)2|(% style="width:700px" %)refresh camera display object 2340 2340 2341 -**Camera state: **It shows the current camera states. Itoccupies a word address. Different value means different operations, as below table shows: 2345 +**Camera state: **It shows the current camera states. It occupies a word address. Different value means different operations, as below table shows: 2342 2342 2343 2343 (% class="table-bordered" %) 2344 2344 |=**Value**|=**Operation** ... ... @@ -2359,11 +2359,11 @@ 2359 2359 2360 2360 The current screenshots are only allowed on the SD card. When the SD card does not exist the system will cache the latest 10 screenshots. 2361 2361 2362 -**Picture name: **The name of the image is controlled by the address.The length of the file name is limited to 64 words. If the image name address is not set, it will be named according to the time and displayed as [YYYYMMDDHHMMSS.bmp] and screenshot format is [.bmp]. 2366 +**Picture name: **The name of the image is controlled by the address. The length of the file name is limited to 64 words. If the image name address is not set, it will be named according to the time and displayed as [YYYYMMDDHHMMSS.bmp] and screenshot format is [.bmp]. 2363 2363 2364 2364 **4) Global screenshot** 2365 2365 2366 -If this function is enable, camera display object can perform the screenshot operation when HMI is running and save it as a .BMP image. 2370 +If this function is enabled, camera display object can perform the screenshot operation when HMI is running and save it as a . BMP image. 2367 2367 2368 2368 If this function is disabled, camera display object only performs the screenshot operation when it is displayed on screen. 2369 2369 ... ... @@ -2373,15 +2373,15 @@ 2373 2373 2374 2374 **6) Use resolution size** 2375 2375 2376 -Coordinate displays the object location in the screen, and size is the length and width of the object.2380 +Coordinate displays the object location on the screen, and size is the length and width of the object. 2377 2377 2378 2378 **✎Note:** 2379 2379 2380 2380 * When using USB camera, HD USB camera is not recommended, which is limited by the resolution displayed by HMI itself. 2381 -* When HMI is displayed horizontally, the USB camera screen displays normally.If select vertical display, USB camera can't display normally. (USB camera can only display normally when the display Angle of HMI is 0.) 2385 +* When HMI is displayed horizontally, the USB camera screen displays normally. If select vertical display, USB camera can't display normally. (USB camera can only display normally when the display Angle of HMI is 0.) 2382 2382 * One HMI is only allowed to connect with one USB camera device. There is only one USB camera display part in the whole project screen, and the camera display part is not allowed to be placed on the public screen (1002: common Windows). 2383 2383 * Sometimes the USB camera may lose the image because of the influence in the field, then we suggest to PI9000 HMI and the recommended USB camera model. 2384 -* All below USB camera model have been tested by WECON to ensure thecompatibility.2388 +* All below USB camera model have been tested by WECON to ensure compatibility. 2385 2385 * Currently, only PI8000 and PI9000 series support the USB camera function. Recommended USB cameras include: 2386 2386 ** REB-USB 100W07M (supports 720p) 2387 2387 ** WX152HD (supports 720p) ... ... @@ -2390,10 +2390,8 @@ 2390 2390 2391 2391 == **Camera control** == 2392 2392 2393 - **Introduction**2397 +This is for control camera; This object need to be used with camera display object. 2394 2394 2395 -This is for control camera; this object need to be used with camera display object. 2396 - 2397 2397 **Description** 2398 2398 2399 2399 (% style="text-align:center" %) ... ... @@ -2403,11 +2403,11 @@ 2403 2403 2404 2404 Read a string from designated system address, and then combine the instruction to control the camera image. 2405 2405 2406 -When the dynamic control command is disabled, the complete camera control command beentered in order to display the camera contents.2408 +When the dynamic control command is disabled, the complete camera control command is entered in order to display the camera contents. 2407 2407 2408 2408 **2) Camera control instruction** 2409 2409 2410 -This is for enter static instruction for camera ,so that users can operationcamera when HMI running;2412 +This is for entering static instruction for camera so that users can operate camera when HMI running. 2411 2411 2412 2412 **3) Control bit** 2413 2413 ... ... @@ -2419,7 +2419,7 @@ 2419 2419 2420 2420 == **Flow component** == 2421 2421 2422 -The flow components are mainly used to reflect the flow state in process flow production. Youcould set the style of flow components according to requirements.2424 +The flow components are mainly used to reflect the flow state in process flow production. User could set the style of flow components according to requirements. 2423 2423 2424 2424 **Description** 2425 2425