Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2194,7 +2194,7 @@ 2194 2194 The camera configured via ip only supports, turn on, turn off, screenshot basic functions. 2195 2195 ))) 2196 2196 2197 -**EZVIZ Cloud Desc irption**2197 +**EZVIZ Cloud Description** 2198 2198 2199 2199 (% style="text-align:center" %) 2200 2200 [[image:企业微信截图_1673081149790.png]] ... ... @@ -2300,23 +2300,23 @@ 2300 2300 |=(% style="width: 129px;" %)60020|(% style="width:366px" %)Unsupport this command|(% style="width:531px" %)Confirm the device whether supports this operation or not 2301 2301 2302 2302 (% class="wikigeneratedid" %) 2303 -**Default Configuration**:Enable the default configuration, the initialization of the EZVIZ cloud camera display components will use the default configuration for binding, the screen can also be modified through the function address configuration information; do not enable the default configuration, the default initial configuration of the EZVIZ cloud camera display components are empty. 2303 +**Default Configuration**: Enable the default configuration, the initialization of the EZVIZ cloud camera display components will use the default configuration for binding, the screen can also be modified through the function address configuration information; do not enable the default configuration, the default initial configuration of the EZVIZ cloud camera display components are empty. 2304 2304 2305 2305 **In the default configuration, the following are required:** 2306 2306 2307 -**AppKey**:EZVIZ cloud application information AppKey, up to 32 characters in length, only letters and numbers can be entered, which can be obtained through the EZVIZ cloud open platform. 2308 -**Secret**:EZVIZ cloud application information Secret, up to 32 characters in length, only letters and numbers can be entered, available through the EZVIZ cloud open platform. 2309 -**Channel number**:EZVIZ cloud device source channel number, 1~~65535, no special modification, generally defaulted to 1, which can be obtained by viewing the EZVIZ cloud client software. 2307 +**AppKey**: EZVIZ cloud application information AppKey, up to 32 characters in length, only letters and numbers can be entered, which can be obtained through the EZVIZ cloud open platform. 2308 +**Secret**: EZVIZ cloud application information Secret, up to 32 characters in length, only letters and numbers can be entered, available through the EZVIZ cloud open platform. 2309 +**Channel number**: EZVIZ cloud device source channel number, 1~~65535, no special modification, generally defaulted to 1, which can be obtained by viewing the EZVIZ cloud client software. 2310 2310 2311 -**S/N:**EZVIZ cloud device serial number, 0 to 80 characters in length, only letters, numbers and "-" can be entered, which can be obtained through the device information. 2311 +**S/N: **EZVIZ cloud device serial number, 0 to 80 characters in length, only letters, numbers and "-" can be entered, which can be obtained through the device information. 2312 2312 2313 2313 2314 2314 **In the default configuration, the following are optional:** 2315 2315 2316 -**IP**:EZVIZ cloud device IP, which can be obtained by viewing the EZVIZ cloud client software. 2316 +**IP**: EZVIZ cloud device IP, which can be obtained by viewing the EZVIZ cloud client software. 2317 2317 2318 -**RTSP Port**:EZVIZ cloud device source rtsp port number, range 0~~65535, no special modification, generally default to 554, can be obtained by viewing the EZVIZ cloud client software. 2319 -**Verification Code**:EZVIZ cloud device authentication code, up to 32 characters in length, obtainable through device information. 2318 +**RTSP Port**: EZVIZ cloud device source rtsp port number, range 0~~65535, no special modification, generally default to 554, can be obtained by viewing the EZVIZ cloud client software. 2319 +**Verification Code**: EZVIZ cloud device authentication code, up to 32 characters in length, obtainable through device information. 2320 2320 2321 2321 {{info}} 2322 2322 **✎Note: **The required content in the configuration only supports remote monitoring when the camera screen can be displayed, if there is a demand for the screen side can also display the camera screen, user need to fill in the optional content in the configuration. ... ... @@ -2324,9 +2324,8 @@ 2324 2324 2325 2325 === **USB Camera** === 2326 2326 2327 +**(1) General** 2327 2327 2328 -1. General 2329 - 2330 2330 (% style="text-align:center" %) 2331 2331 [[image:6.Objects_html_6d926ea40f8267c.gif||class="img-thumbnail"]] 2332 2332 ... ... @@ -2343,7 +2343,7 @@ 2343 2343 |(% style="width:144px" %)1|(% style="width:700px" %)Enable the screenshot function 2344 2344 |(% style="width:144px" %)2|(% style="width:700px" %)refresh camera display object 2345 2345 2346 -**Camera state: **It shows the current camera states. Itoccupies a word address. Different value means different operations, as below table shows: 2345 +**Camera state: **It shows the current camera states. It occupies a word address. Different value means different operations, as below table shows: 2347 2347 2348 2348 (% class="table-bordered" %) 2349 2349 |=**Value**|=**Operation** ... ... @@ -2364,11 +2364,11 @@ 2364 2364 2365 2365 The current screenshots are only allowed on the SD card. When the SD card does not exist the system will cache the latest 10 screenshots. 2366 2366 2367 -**Picture name: **The name of the image is controlled by the address.The length of the file name is limited to 64 words. If the image name address is not set, it will be named according to the time and displayed as [YYYYMMDDHHMMSS.bmp] and screenshot format is [.bmp]. 2366 +**Picture name: **The name of the image is controlled by the address. The length of the file name is limited to 64 words. If the image name address is not set, it will be named according to the time and displayed as [YYYYMMDDHHMMSS.bmp] and screenshot format is [.bmp]. 2368 2368 2369 2369 **4) Global screenshot** 2370 2370 2371 -If this function is enable, camera display object can perform the screenshot operation when HMI is running and save it as a .BMP image. 2370 +If this function is enabled, camera display object can perform the screenshot operation when HMI is running and save it as a . BMP image. 2372 2372 2373 2373 If this function is disabled, camera display object only performs the screenshot operation when it is displayed on screen. 2374 2374 ... ... @@ -2378,15 +2378,15 @@ 2378 2378 2379 2379 **6) Use resolution size** 2380 2380 2381 -Coordinate displays the object location in the screen, and size is the length and width of the object.2380 +Coordinate displays the object location on the screen, and size is the length and width of the object. 2382 2382 2383 2383 **✎Note:** 2384 2384 2385 2385 * When using USB camera, HD USB camera is not recommended, which is limited by the resolution displayed by HMI itself. 2386 -* When HMI is displayed horizontally, the USB camera screen displays normally.If select vertical display, USB camera can't display normally. (USB camera can only display normally when the display Angle of HMI is 0.) 2385 +* When HMI is displayed horizontally, the USB camera screen displays normally. If select vertical display, USB camera can't display normally. (USB camera can only display normally when the display Angle of HMI is 0.) 2387 2387 * One HMI is only allowed to connect with one USB camera device. There is only one USB camera display part in the whole project screen, and the camera display part is not allowed to be placed on the public screen (1002: common Windows). 2388 2388 * Sometimes the USB camera may lose the image because of the influence in the field, then we suggest to PI9000 HMI and the recommended USB camera model. 2389 -* All below USB camera model have been tested by WECON to ensure thecompatibility.2388 +* All below USB camera model have been tested by WECON to ensure compatibility. 2390 2390 * Currently, only PI8000 and PI9000 series support the USB camera function. Recommended USB cameras include: 2391 2391 ** REB-USB 100W07M (supports 720p) 2392 2392 ** WX152HD (supports 720p) ... ... @@ -2395,10 +2395,8 @@ 2395 2395 2396 2396 == **Camera control** == 2397 2397 2398 - **Introduction**2397 +This is for control camera; This object need to be used with camera display object. 2399 2399 2400 -This is for control camera; this object need to be used with camera display object. 2401 - 2402 2402 **Description** 2403 2403 2404 2404 (% style="text-align:center" %) ... ... @@ -2408,11 +2408,11 @@ 2408 2408 2409 2409 Read a string from designated system address, and then combine the instruction to control the camera image. 2410 2410 2411 -When the dynamic control command is disabled, the complete camera control command beentered in order to display the camera contents.2408 +When the dynamic control command is disabled, the complete camera control command is entered in order to display the camera contents. 2412 2412 2413 2413 **2) Camera control instruction** 2414 2414 2415 -This is for enter static instruction for camera ,so that users can operationcamera when HMI running;2412 +This is for entering static instruction for camera so that users can operate camera when HMI running. 2416 2416 2417 2417 **3) Control bit** 2418 2418 ... ... @@ -2424,7 +2424,7 @@ 2424 2424 2425 2425 == **Flow component** == 2426 2426 2427 -The flow components are mainly used to reflect the flow state in process flow production. Youcould set the style of flow components according to requirements.2424 +The flow components are mainly used to reflect the flow state in process flow production. User could set the style of flow components according to requirements. 2428 2428 2429 2429 **Description** 2430 2430 ... ... @@ -2444,9 +2444,9 @@ 2444 2444 1. **Block width:** It sets block width of flow component. 2445 2445 1. **PipeFrn width: **It sets outer border width of flow component. 2446 2446 1. **Block length: **It sets block length of flow component. 2447 -1. **Transparence:** It sets transparence of flow component.(from opaque (0) to full transparence (100)). You could cooperate with transparence and other settings to meet display requirements. 2448 -1. **Ratio:** It sets display ratio of block and background (Display density of the block in flow component). 2449 -1. **Speed:** It setsflow speed of the block during HMI running. 2444 +1. **Transparence:** It sets transparence of flow component. (from opaque (0) to full transparence (100)). You could cooperate with transparence and other settings to meet display requirements. 2445 +1. **Ratio:** It sets the display ratio of block and background (Display density of the block in flow component). 2446 +1. **Speed:** It sets flow speed of the block during HMI running. 2450 2450 2451 2451 **(3) Control** 2452 2452 ... ... @@ -2470,9 +2470,9 @@ 2470 2470 2471 2471 == **Printer** == 2472 2472 2473 -The printing object is primarily suitable for print out or screenshots saving when connected to micro printer. 2470 +The printing object is primarily suitable for printing out or screenshots saving when connected to micro printer. 2474 2474 2475 -Printer has two types: **serial printer and USB printer**. Printf (printext function) should be called when it's used to print fixed message in a script.2472 +Printer has two types: serial printer and USB printer. Printf (printext function) should be called when it's used to print fixed message in a script. 2476 2476 2477 2477 **Printer protocol** 2478 2478 ... ... @@ -2492,18 +2492,18 @@ 2492 2492 **(1) Display settings** 2493 2493 2494 2494 1. **Direction: **Four direction choices in printing: 0, 90, 180, and 270. 2495 -1. **Zoom in: **Check "Zoom in" to zoom printing content in proportion withpaper size.2492 +1. **Zoom in: **Check "Zoom in" to zoom printing content in proportion to paper size. 2496 2496 2497 2497 **(2) Trigger mode** 2498 2498 2499 -1. **Trigger address: **When trigger address turns ON. Printer starts to respond operation.2496 +1. **Trigger address: **When trigger address turns ON. The printer starts to respond operationally. 2500 2500 1. **Printer\ Save:** It sets operation for this object, printer object could support sending printing command to printer device, and including screenshot. 2501 2501 2502 2502 **(3) Save path** 2503 2503 2504 -Valid when the save mode is selected, screenshot the content in printing object area and thesave it in specified storage and folder, when trigger address turns ON.2501 +Valid when the save mode is selected, screenshot the content in printing object area, and save it in specified storage and folder, when trigger address turns ON. 2505 2505 2506 -Folder: It's available to select SD card or USB disk. Set the file name to "Abc" in folder, and it would automatically generate a folder "Abc" when you save picture first time, and all the pictures will save in this folder. The folder name consists of mixed uppercase and lowercase letters and numbers within 32 characters. 2503 +Folder: It's available to select an SD card or USB disk. Set the file name to "Abc" in folder, and it would automatically generate a folder "Abc" when you save picture the first time, and all the pictures will save in this folder. The folder name consists of mixed uppercase and lowercase letters and numbers within 32 characters. 2507 2507 2508 2508 **Related issues** 2509 2509 ... ... @@ -2598,8 +2598,6 @@ 2598 2598 2599 2599 It adds text to HMI screen, and a object can be displayed in 8 languages (set in "All Languages") with a special address setting. 2600 2600 2601 -**Description** 2602 - 2603 2603 (% style="text-align:center" %) 2604 2604 [[image:6.Objects_html_3cae6153cc6e4750.gif||class="img-thumbnail"]] 2605 2605