Changes for page 05 Objects

Last modified by Jett on 2025/07/04 09:41

From version 72.1
edited by Jim(Forgotten)
on 2023/08/10 17:11
Change comment: There is no comment for this version
To version 44.1
edited by Karen
on 2023/05/24 18:13
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Jim
1 +XWiki.Karen
Content
... ... @@ -458,8 +458,6 @@
458 458  * **Run times: **Configuration sub-function execute times. 0 means unlimited times.
459 459  * **Break:** Stop executing sub-function when trigger address is ON.
460 460  
461 -(% class="box infomessage" %)
462 -(((
463 463  ✎**Note:**
464 464  
465 465  * Nested patterns of object cycle and sub-function cycles are as follows.
... ... @@ -469,7 +469,6 @@
469 469  ** If the object cycle ends later than the sub-function cycle, the sub-function cycle would be triggered again.
470 470  ** If the main cycle is triggered again before it finishes, then the main cycle is executed immediately when clicked and only one more time.
471 471  * For [[text>>https://docs.we-con.com.cn/bin/view/PIStudio/7.Library/#HText]]/[[graphics>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HGraphic]]/[[security>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HSecurity]]/[[animations>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HAnimation]], see the "[[Bit Switch>>path:https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]".
472 -)))
473 473  
474 474  == Slider switch ==
475 475  
... ... @@ -1388,7 +1388,7 @@
1388 1388  
1389 1389  == **Pointer meter** ==
1390 1390  
1391 -The meter responds to change in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1388 +The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1392 1392  
1393 1393  (% style="text-align:center" %)
1394 1394  [[image:image-20220805161001-1.jpeg]]
... ... @@ -1403,13 +1403,13 @@
1403 1403  * 32-bit signed decimal
1404 1404  * 32-bit unsigned decimal
1405 1405  
1406 -**Digits setting:** Set directly the maximum and the minimum. Only when the floating point number is selected, can the maximum and minimum value be with a decimal point, and other data formats can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.
1403 +**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.
1407 1407  
1408 1408  * **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1409 1409  
1410 -**Variable limits:** When checked, low limit address and high limit address could be edit showed below;
1407 +**Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1411 1411  
1412 -**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select according to needs.
1409 +**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs.
1413 1413  
1414 1414  **Show pointer**: When not checked, the pointer is not displayed; When checked, you could set the style and color of pointer.
1415 1415  
... ... @@ -1417,15 +1417,15 @@
1417 1417  
1418 1418  **Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value.
1419 1419  
1420 -**Meter Type:** It sets the angle between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1417 +**Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1421 1421  
1422 1422  **Start angle: **It sets the position where the minimum value is displayed.
1423 1423  
1424 -**Position&size:** Set the position of the object on the screen and the size of the object. The object is displayed as square. If the width or the height of the object is changed, the other data will also be changed.
1421 +**Position&size:** Set the position of the object in the screen and the size of the object. The object is displayed as square. If the width or the height of the object is changed, the other data will also be changed.
1425 1425  
1426 1426  **Result**
1427 1427  
1428 -When configuration is completed, the object is shown below picture when HMI is running.
1425 +When configuration is completed, the object is shown as below picture when HMI is running.
1429 1429  
1430 1430  (% style="text-align:center" %)
1431 1431  [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]]
... ... @@ -1608,10 +1608,13 @@
1608 1608  
1609 1609  == **QR Code** ==
1610 1610  
1608 +**Introduction**
1609 +
1611 1611  It is similar to the universal QR code. You could scan this object to get the connection or content, but it provides content settings for QR code.
1612 1612  
1613 1613  **Description**
1614 1614  
1614 +
1615 1615  (% style="text-align:center" %)
1616 1616  [[image:6.Objects_html_4cf155075ac97d16.gif||class="img-thumbnail"]]
1617 1617  
... ... @@ -1623,7 +1623,7 @@
1623 1623  **✎Note:**
1624 1624  
1625 1625  * HMI machine ID address: HSW10494 ~~ HSW10558.
1626 -* So if user want to use QR code to display machine ID on project screen, please check "Variable QR", and set address is HSW10494.
1626 +* So if user want to use QR code to display machine ID in project screen, please check "Variable QR", and set address is HSW10494.
1627 1627  * When scanning the QR code by APP to monitor HMI, the default access password is 888888.
1628 1628  
1629 1629  == **Picture** ==
... ... @@ -1649,9 +1649,9 @@
1649 1649  
1650 1650  This is advanced function of picture object; user can change display picture when HMI is running. The supported formats are bmp, jpg, png, jpeg. This feature is unavailable for offline and online simulation.
1651 1651  
1652 -1. **Root: **Set the save location of the picture, which can be set to U disk,SD card,but could not be set to Flash.
1652 +1. **Root: **Set the save location of the picture,which can be set to U disk,SD card,but could not be set to Flash.
1653 1653  1. **Folder: **Set the name of the folder where the picture is located.The folder name can be up to 31 characters. (Note:The picture must be stored in the U disk folder and cannot be stored in the root directory of the U disk.)
1654 -1. **File address: **16 consecutive addresses enter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed.
1654 +1. **File address: **16 consecutive addressesenter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed.
1655 1655  
1656 1656  ✎**Note:** 
1657 1657  
... ... @@ -1684,7 +1684,7 @@
1684 1684  * **Min. angle:** It sets the starting angle of rotation (Valid in auto-rotation mode).
1685 1685  * **Max. angle:** It sets the ending angle of rotation (Valid in auto-rotation mode).
1686 1686  
1687 -**Rotation angle: **The rotating angle is determined by designated address;
1687 +**Rotation angle: **the rotating angle is determined by designated address;
1688 1688  
1689 1689  **Rotation center**: It shows the rotation center coordinates;
1690 1690  
... ... @@ -1698,7 +1698,7 @@
1698 1698  
1699 1699  **Enable auto-spin: **When the address is set to ON, the picture will rotate automatically.
1700 1700  
1701 -**Hide:** Control the hiding status of the object through the status of the control bit address. The hiding mode can be divided into hide when OFF and hide when ON.
1701 +**Hide:** control the hiding status of the object through the status of the control bit address. The hiding mode can be divided into hide when OFF and hide when ON.
1702 1702  
1703 1703  == **Drop-down List** ==
1704 1704  
... ... @@ -1714,18 +1714,18 @@
1714 1714  **1) Edit**
1715 1715  
1716 1716  1. **Read Address:** The data from designated address will be displayed.
1717 -1. **Same read-write address:** Configure "Write Address" as the same as "Read Address".
1718 -1. **Write Address: **Write data to designated address. The address can be different from "Read Address".
1717 +1. **Same read-write address:** Configure "Write Address" is the same as "Read Address".
1718 +1. **Write Address: **Write data to designated address. The address can be different "Read Address".
1719 1719  
1720 1720  **2) Format**
1721 1721  
1722 -Set data format for object, it provides 16-bit unsigned decimal,16-bit BCD, 16-bit unsigned decimal, 32-bit BCD, 32-bit unsigned decimal, and 32-bit unsigned decimal.
1722 +Set data format for object, it provides 16-bit unsigned decimal,16-bit BCD, 16-bit unsigned decimal, 32-bit BCD, 32-bit unsigned decimal and 32-bit unsigned decimal.
1723 1723  
1724 1724  **3) State count**
1725 1725  
1726 1726  It could set the total number to display in the drop-list and supports up to 128 states (1 to 128). The default value of state is corresponding to the number of states. (State 1 corresponding to value 1). You can also click "state values" to set it according to your needs.
1727 1727  
1728 -**State value: **User can set different values to correspond to different states, the setting window as below figure shows.
1728 +**State value: **You can set different values to correspond to different states, the setting window as below figure shows.
1729 1729  
1730 1730  (% style="text-align:center" %)
1731 1731  [[image:6.Objects_html_da9a6696f320b427.gif||class="img-thumbnail"]]
... ... @@ -1769,12 +1769,12 @@
1769 1769  
1770 1770  **3) Read state text from address**
1771 1771  
1772 -1. **Text start address: **The first address of occupied multiple consecutive addresses. Address length: [Text length/2] *[state number +1].
1772 +1. **Text start address: **the first address of occupied multiple consecutive addresses. Address length: [Text length/2] *[state number +1].
1773 1773  
1774 1774  * For example: 10 states, the address length= (10/2) *(10+1) =55. It set HDW100 as start address, so the HDW100-HDW104 stores the currently selected text content, the HDW105-HDW109 displays the text in the first state, the HDW110-HDW114 displays the second, and so on.
1775 1775  
1776 1776  (% start="2" %)
1777 -1. **Refresh: **The drop-down list status value is updated according to the text address content. The drop-down list is not updated immediately, when the data in the text address change is completed, only the refresh is triggered, it will update.
1777 +1. **Refresh:**The drop-down list status value is updated according to the text address content.The drop-down list is not updated immediately, when the data in the text address change is completed, only the refresh is triggered, it will update.
1778 1778  
1779 1779  == **Camera display** ==
1780 1780  
... ... @@ -1786,8 +1786,6 @@
1786 1786  
1787 1787  === **IP Camera** ===
1788 1788  
1789 -**(1) General**
1790 -
1791 1791  (% style="text-align:center" %)
1792 1792  [[image:6.Objects_html_2bc22bd50bf65eb.gif||class="img-thumbnail"]]
1793 1793  
... ... @@ -2197,7 +2197,7 @@
2197 2197  The camera configured via ip only supports, turn on, turn off, screenshot basic functions.
2198 2198  )))
2199 2199  
2200 -**EZVIZ Cloud Description**
2198 +**EZVIZ Cloud Descirption**
2201 2201  
2202 2202  (% style="text-align:center" %)
2203 2203  [[image:企业微信截图_1673081149790.png]]
... ... @@ -2303,23 +2303,23 @@
2303 2303  |=(% style="width: 129px;" %)60020|(% style="width:366px" %)Unsupport this command|(% style="width:531px" %)Confirm the device whether supports this operation or not
2304 2304  
2305 2305  (% class="wikigeneratedid" %)
2306 -**Default Configuration**: Enable the default configuration, the initialization of the EZVIZ cloud camera display components will use the default configuration for binding, the screen can also be modified through the function address configuration information; do not enable the default configuration, the default initial configuration of the EZVIZ cloud camera display components are empty.
2304 +**Default Configuration**:Enable the default configuration, the initialization of the EZVIZ cloud camera display components will use the default configuration for binding, the screen can also be modified through the function address configuration information; do not enable the default configuration, the default initial configuration of the EZVIZ cloud camera display components are empty.
2307 2307  
2308 2308  **In the default configuration, the following are required:**
2309 2309  
2310 -**AppKey**: EZVIZ cloud application information AppKey, up to 32 characters in length, only letters and numbers can be entered, which can be obtained through the EZVIZ cloud open platform.
2311 -**Secret**: EZVIZ cloud application information Secret, up to 32 characters in length, only letters and numbers can be entered, available through the EZVIZ cloud open platform.
2312 -**Channel number**: EZVIZ cloud device source channel number, 1~~65535, no special modification, generally defaulted to 1, which can be obtained by viewing the EZVIZ cloud client software.
2308 +**AppKey**:EZVIZ cloud application information AppKey, up to 32 characters in length, only letters and numbers can be entered, which can be obtained through the EZVIZ cloud open platform.
2309 +**Secret**:EZVIZ cloud application information Secret, up to 32 characters in length, only letters and numbers can be entered, available through the EZVIZ cloud open platform.
2310 +**Channel number**:EZVIZ cloud device source channel number, 1~~65535, no special modification, generally defaulted to 1, which can be obtained by viewing the EZVIZ cloud client software.
2313 2313  
2314 -**S/N: **EZVIZ cloud device serial number, 0 to 80 characters in length, only letters, numbers and "-" can be entered, which can be obtained through the device information.
2312 +**S/N:**EZVIZ cloud device serial number, 0 to 80 characters in length, only letters, numbers and "-" can be entered, which can be obtained through the device information.
2315 2315  
2316 2316  
2317 2317  **In the default configuration, the following are optional:**
2318 2318  
2319 -**IP**: EZVIZ cloud device IP, which can be obtained by viewing the EZVIZ cloud client software.
2317 +**IP**:EZVIZ cloud device IP, which can be obtained by viewing the EZVIZ cloud client software.
2320 2320  
2321 -**RTSP Port**: EZVIZ cloud device source rtsp port number, range 0~~65535, no special modification, generally default to 554, can be obtained by viewing the EZVIZ cloud client software.
2322 -**Verification Code**: EZVIZ cloud device authentication code, up to 32 characters in length, obtainable through device information.
2319 +**RTSP Port**:EZVIZ cloud device source rtsp port number, range 0~~65535, no special modification, generally default to 554, can be obtained by viewing the EZVIZ cloud client software.
2320 +**Verification Code**:EZVIZ cloud device authentication code, up to 32 characters in length, obtainable through device information.
2323 2323  
2324 2324  {{info}}
2325 2325  **✎Note: **The required content in the configuration only supports remote monitoring when the camera screen can be displayed, if there is a demand for the screen side can also display the camera screen, user need to fill in the optional content in the configuration.
... ... @@ -2327,8 +2327,6 @@
2327 2327  
2328 2328  === **USB Camera** ===
2329 2329  
2330 -**(1) General**
2331 -
2332 2332  (% style="text-align:center" %)
2333 2333  [[image:6.Objects_html_6d926ea40f8267c.gif||class="img-thumbnail"]]
2334 2334  
... ... @@ -2345,7 +2345,7 @@
2345 2345  |(% style="width:144px" %)1|(% style="width:700px" %)Enable the screenshot function
2346 2346  |(% style="width:144px" %)2|(% style="width:700px" %)refresh camera display object
2347 2347  
2348 -**Camera state: **It shows the current camera states. It occupies a word address. Different value means different operations, as below table shows:
2344 +**Camera state: **It shows the current camera states. Itoccupies a word address. Different value means different operations, as below table shows:
2349 2349  
2350 2350  (% class="table-bordered" %)
2351 2351  |=**Value**|=**Operation**
... ... @@ -2366,11 +2366,11 @@
2366 2366  
2367 2367  The current screenshots are only allowed on the SD card. When the SD card does not exist the system will cache the latest 10 screenshots.
2368 2368  
2369 -**Picture name: **The name of the image is controlled by the address. The length of the file name is limited to 64 words. If the image name address is not set, it will be named according to the time and displayed as [YYYYMMDDHHMMSS.bmp] and screenshot format is [.bmp].
2365 +**Picture name: **The name of the image is controlled by the address.The length of the file name is limited to 64 words. If the image name address is not set, it will be named according to the time and displayed as [YYYYMMDDHHMMSS.bmp] and screenshot format is [.bmp].
2370 2370  
2371 2371  **4) Global screenshot**
2372 2372  
2373 -If this function is enabled, camera display object can perform the screenshot operation when HMI is running and save it as a . BMP image.
2369 +If this function is enable, camera display object can perform the screenshot operation when HMI is running and save it as a .BMP image.
2374 2374  
2375 2375  If this function is disabled, camera display object only performs the screenshot operation when it is displayed on screen.
2376 2376  
... ... @@ -2380,15 +2380,15 @@
2380 2380  
2381 2381  **6) Use resolution size**
2382 2382  
2383 -Coordinate displays the object location on the screen, and size is the length and width of the object.
2379 +Coordinate displays the object location in the screen, and size is the length and width of the object.
2384 2384  
2385 2385  **✎Note:**
2386 2386  
2387 2387  * When using USB camera, HD USB camera is not recommended, which is limited by the resolution displayed by HMI itself.
2388 -* When HMI is displayed horizontally, the USB camera screen displays normally. If select vertical display, USB camera can't display normally. (USB camera can only display normally when the display Angle of HMI is 0.)
2384 +* When HMI is displayed horizontally, the USB camera screen displays normally.If select vertical display, USB camera can't display normally. (USB camera can only display normally when the display Angle of HMI is 0.)
2389 2389  * One HMI is only allowed to connect with one USB camera device. There is only one USB camera display part in the whole project screen, and the camera display part is not allowed to be placed on the public screen (1002: common Windows).
2390 2390  * Sometimes the USB camera may lose the image because of the influence in the field, then we suggest to PI9000 HMI and the recommended USB camera model.
2391 -* All below USB camera model have been tested by WECON to ensure compatibility.
2387 +* All below USB camera model have been tested by WECON to ensure the compatibility.
2392 2392  * Currently, only PI8000 and PI9000 series support the USB camera function. Recommended USB cameras include:
2393 2393  ** REB-USB 100W07M (supports 720p)
2394 2394  ** WX152HD (supports 720p)
... ... @@ -2397,8 +2397,10 @@
2397 2397  
2398 2398  == **Camera control** ==
2399 2399  
2400 -This is for control camera; This object need to be used with camera display object.
2396 +**Introduction**
2401 2401  
2398 +This is for control camera; this object need to be used with camera display object.
2399 +
2402 2402  **Description**
2403 2403  
2404 2404  (% style="text-align:center" %)
... ... @@ -2408,11 +2408,11 @@
2408 2408  
2409 2409  Read a string from designated system address, and then combine the instruction to control the camera image.
2410 2410  
2411 -When the dynamic control command is disabled, the complete camera control command is entered in order to display the camera contents.
2409 +When the dynamic control command is disabled, the complete camera control command be entered in order to display the camera contents.
2412 2412  
2413 2413  **2) Camera control instruction**
2414 2414  
2415 -This is for entering static instruction for camera so that users can operate camera when HMI running.
2413 +This is for enter static instruction for camera, so that users can operation camera when HMI running;
2416 2416  
2417 2417  **3) Control bit**
2418 2418  
... ... @@ -2424,7 +2424,7 @@
2424 2424  
2425 2425  == **Flow component** ==
2426 2426  
2427 -The flow components are mainly used to reflect the flow state in process flow production. User could set the style of flow components according to requirements.
2425 +The flow components are mainly used to reflect the flow state in process flow production. You could set the style of flow components according to requirements.
2428 2428  
2429 2429  **Description**
2430 2430  
... ... @@ -2444,9 +2444,9 @@
2444 2444  1. **Block width:** It sets block width of flow component.
2445 2445  1. **PipeFrn width: **It sets outer border width of flow component.
2446 2446  1. **Block length: **It sets block length of flow component.
2447 -1. **Transparence:** It sets transparence of flow component. (from opaque (0) to full transparence (100)). You could cooperate with transparence and other settings to meet display requirements.
2448 -1. **Ratio:** It sets the display ratio of block and background (Display density of the block in flow component).
2449 -1. **Speed:** It sets flow speed of the block during HMI running.
2445 +1. **Transparence:** It sets transparence of flow component.(from opaque (0) to full transparence (100)). You could cooperate with transparence and other settings to meet display requirements.
2446 +1. **Ratio:** It sets display ratio of block and background (Display density of the block in flow component).
2447 +1. **Speed:** It setsflow speed of the block during HMI running.
2450 2450  
2451 2451  **(3) Control**
2452 2452  
... ... @@ -2470,9 +2470,9 @@
2470 2470  
2471 2471  == **Printer** ==
2472 2472  
2473 -The printing object is primarily suitable for printing out or screenshots saving when connected to micro printer.
2471 +The printing object is primarily suitable for print out or screenshots saving when connected to micro printer.
2474 2474  
2475 -Printer has two types: serial printer and USB printer. Printf (printext function) should be called when it's used to print fixed message in a script.
2473 +Printer has two types: **serial printer and USB printer**. Printf (printext function) should be called when it's used to print fixed message in a script.
2476 2476  
2477 2477  **Printer protocol**
2478 2478  
... ... @@ -2492,18 +2492,18 @@
2492 2492  **(1) Display settings**
2493 2493  
2494 2494  1. **Direction: **Four direction choices in printing: 0, 90, 180, and 270.
2495 -1. **Zoom in: **Check "Zoom in" to zoom printing content in proportion to paper size.
2493 +1. **Zoom in: **Check "Zoom in" to zoom printing content in proportion with paper size.
2496 2496  
2497 2497  **(2) Trigger mode**
2498 2498  
2499 -1. **Trigger address: **When trigger address turns ON. The printer starts to respond operationally.
2497 +1. **Trigger address: **When trigger address turns ON.Printer starts to respond operation.
2500 2500  1. **Printer\ Save:** It sets operation for this object, printer object could support sending printing command to printer device, and including screenshot.
2501 2501  
2502 2502  **(3) Save path**
2503 2503  
2504 -Valid when the save mode is selected, screenshot the content in printing object area, and save it in specified storage and folder, when trigger address turns ON.
2502 +Valid when the save mode is selected, screenshot the content in printing object area and the save it in specified storage and folder, when trigger address turns ON.
2505 2505  
2506 -Folder: It's available to select an SD card or USB disk. Set the file name to "Abc" in folder, and it would automatically generate a folder "Abc" when you save picture the first time, and all the pictures will save in this folder. The folder name consists of mixed uppercase and lowercase letters and numbers within 32 characters.
2504 +Folder: It's available to select SD card or USB disk. Set the file name to "Abc" in folder, and it would automatically generate a folder "Abc" when you save picture first time, and all the pictures will save in this folder. The folder name consists of mixed uppercase and lowercase letters and numbers within 32 characters.
2507 2507  
2508 2508  **Related issues**
2509 2509  
... ... @@ -2596,14 +2596,16 @@
2596 2596  
2597 2597  == **Text** ==
2598 2598  
2599 -It adds text to HMI screen, and an object can be displayed in 8 languages (set in "All Languages") with a special address setting.
2597 +It adds text to HMI screen, and a object can be displayed in 8 languages (set in "All Languages") with a special address setting.
2600 2600  
2599 +**Description**
2600 +
2601 2601  (% style="text-align:center" %)
2602 2602  [[image:6.Objects_html_3cae6153cc6e4750.gif||class="img-thumbnail"]]
2603 2603  
2604 2604  **(1) Current state**
2605 2605  
2606 -It is used to switch the object states, but [Text] object only has one state, so this function is invalid.
2606 +It used to switch the object states, but [Text] object only has one state, so this function is invalid.
2607 2607  
2608 2608  **(2) All language**
2609 2609  
... ... @@ -2622,7 +2622,7 @@
2622 2622  
2623 2623  **(5) Text color**
2624 2624  
2625 -It sets color of text in object.
2625 +It sets color for text in object.
2626 2626  
2627 2627  **(6) Text background**
2628 2628  
... ... @@ -2630,8 +2630,10 @@
2630 2630  
2631 2631  == **Table** ==
2632 2632  
2633 -It is displayed in a table format on the HMI screen to meet the display needs of user.
2633 +It is displayed in a table format in the HMI screen to meet the display needs of user.
2634 2634  
2635 +**Description**
2636 +
2635 2635  (% style="text-align:center" %)
2636 2636  [[image:6.Objects_html_2aad7ef679949d71.gif||class="img-thumbnail"]]
2637 2637  
... ... @@ -2644,7 +2644,7 @@
2644 2644  1. **Border:** It sets table line color, including table line and frame line.
2645 2645  1. **Transparence: **It sets the transparency of the object background.
2646 2646  1. **Fill style: **There are two options for it, one is display background, and the other is no background.
2647 -1. **Background:** Valid when selecting display background in "Fill style".
2649 +1. **Background:** Valid when select display background in "Fill style".
2648 2648  
2649 2649  **(2) View**
2650 2650  
... ... @@ -2654,6 +2654,8 @@
2654 2654  
2655 2655  It is displayed in line format in the HMI screen to meet the display needs of user.
2656 2656  
2659 +**Description**
2660 +
2657 2657  (% style="text-align:center" %)
2658 2658  [[image:6.Objects_html_795af47bf0ad8529.gif||class="img-thumbnail"]]
2659 2659  
... ... @@ -2671,7 +2671,7 @@
2671 2671  
2672 2672  **(3) Coordinate control**
2673 2673  
2674 -Dynamically set the position coordinate between two points in line. Set four addresses respectively corresponding to the starting point and end point coordinate. If the numerical value of coordinate is over interface, the object will not be displayed.
2678 +Dynamically set the position coordinate between two points in line. Set four addressesrespectively corresponding to the starting point and end point coordinate. If the numerical value of coordinate is over interface, the object will not be displayed.
2675 2675  
2676 2676  **(4) Color control**
2677 2677  
... ... @@ -2683,10 +2683,12 @@
2683 2683  
2684 2684  == **Polygon** ==
2685 2685  
2686 -It is displayed in polygon format on the HMI screen to meet the display needs of user.
2690 +It is displayed in polygon format in the HMI screen to meet the display needs of user.
2687 2687  
2688 2688  Right click to close polygon and then complete the creation procedure. Select the polygon, then click its point position to change its vertex coordinate after it is created.
2689 2689  
2694 +**Description**
2695 +
2690 2690  (% style="text-align:center" %)
2691 2691  [[image:6.Objects_html_9f46a2daf3b48e68.gif||class="img-thumbnail"]]
2692 2692  
... ... @@ -2695,7 +2695,7 @@
2695 2695  1. **Border color: **It sets border line color.
2696 2696  1. **Border type:** It sets border line type.
2697 2697  1. **Border width: **It sets border line width.
2698 -1. **Transparence: **It sets the transparency of the object's background.
2704 +1. **Transparence: **It sets the transparency of the object background.
2699 2699  1. **Coordinate editing:** It changes coordinate for all points in this object, as below shows.
2700 2700  
2701 2701  (% style="text-align:center" %)
... ... @@ -2719,8 +2719,10 @@
2719 2719  
2720 2720  == **Cycle/ Ellipse** ==
2721 2721  
2722 -It is displayed as cycle on HMI screen to meet the display needs of user.
2728 +It is displayed as cycle in HMI screen to meet the display needs of user.
2723 2723  
2730 +**Description**
2731 +
2724 2724  (% style="text-align:center" %)
2725 2725  [[image:6.Objects_html_1851aaa90af6ee72.gif||class="img-thumbnail"]]
2726 2726  
... ... @@ -2730,8 +2730,8 @@
2730 2730  1. **Frame width: **It sets border line type.
2731 2731  1. **Frame type: **It sets border line width
2732 2732  1. **Pattern: **It sets background type, there are four types.
2733 -1. **Background: **It sets background color of object, invalid when selecting [No fill] in [Pattern]
2734 -1. **Transparence:** It sets the transparency of the object's background.
2741 +1. **Background: **It sets background color of object, invalid when select [No fill] in [Pattern]
2742 +1. **Transparence:** It sets the transparency of the object background.
2735 2735  
2736 2736  **2) Transparence control**
2737 2737  
... ... @@ -2739,7 +2739,7 @@
2739 2739  
2740 2740  **3) Cycle**
2741 2741  
2742 -Check if it is for circle; uncheck it for ellipse.
2750 +Check if for circle; uncheck it for ellipse.
2743 2743  
2744 2744  **4) Color control**
2745 2745  
... ... @@ -2765,6 +2765,7 @@
2765 2765  
2766 2766  **2) Display settings**
2767 2767  
2776 +
2768 2768  (% style="text-align:center" %)
2769 2769  [[image:6.Objects_html_4729b28f315a5a9b.gif||class="img-thumbnail"]]
2770 2770  
... ... @@ -2773,7 +2773,7 @@
2773 2773  1. **Line width: **It sets border line type.
2774 2774  1. **Fill style: **It sets background type, there are four types.
2775 2775  1. **Transparence:** It sets the transparency of the object background.
2776 -1. **Background: **It sets background color of object, invalid when selecting [No fill] in [Pattern].
2785 +1. **Background: **It sets background color of object, invalid when select [No fill] in [Pattern].
2777 2777  
2778 2778  **(3) Only show arc**
2779 2779  
... ... @@ -2799,6 +2799,8 @@
2799 2799  
2800 2800  The line segments are linked end-to-end to form a broken line, whose vertex coordinate can be modified by drafting, just like polygon.
2801 2801  
2811 +**Description**
2812 +
2802 2802  (% style="text-align:center" %)
2803 2803  [[image:6.Objects_html_c3b0de1d4c2fe745.gif||class="img-thumbnail"]]
2804 2804  
... ... @@ -2821,7 +2821,7 @@
2821 2821  
2822 2822  In basic display settings, the line width can't be changed, but user can change width by address.
2823 2823  
2824 -Read the numerical value of address to control the width of line. Display range of numerical value:1-10.
2835 +Read the numerical value of address to control the width of line.Display range of numerical value:1-10.
2825 2825  
2826 2826  **(4) View**
2827 2827  
... ... @@ -2831,6 +2831,8 @@
2831 2831  
2832 2832  The linear scale is a linear scale that draws the specified area with a bisector. The specific scale of the scale can be marked with static text.
2833 2833  
2845 +**Description**
2846 +
2834 2834  (% style="text-align:center" %)
2835 2835  [[image:6.Objects_html_b604bd83c8b8b6d1.gif||class="img-thumbnail"]]
2836 2836  
... ... @@ -2838,12 +2838,12 @@
2838 2838  
2839 2839  1. **Line color:** It sets all line in object (including main and sub scale).
2840 2840  1. **Display direction: **It provides four modes for display.
2841 -1. **Main scale: **It sets the cell of the main scale.
2854 +1. **Main scale:**It sets the cell of the main scale.
2842 2842  1. **Sub scale:** It sets the cell of sub scale for every main scale.
2843 2843  
2844 2844  **(2) View**
2845 2845  
2846 -It is for preview object.
2859 +It is for preview object;
2847 2847  
2848 2848  == **Arc scale** ==
2849 2849  
... ... @@ -2877,12 +2877,14 @@
2877 2877  
2878 2878  Customized object is provided for users to design the universal interface of object freely to meet customization requirements.
2879 2879  
2893 +**Description**
2894 +
2880 2880  (% style="text-align:center" %)
2881 2881  [[image:6.Objects_html_c8146ad79a9ce732.gif||class="img-thumbnail"]]
2882 2882  
2883 -1. **Function Address:** The numerical value in this address is used as the function code of object to handle the corresponding operation.
2884 -1. **DLL file name: **Select needed dll file. (i.e. dll files provided by users)
2885 -1. **Custom address:** Users can add some function address to cooperate with dll file to complete other operations.
2898 +1. **Function Address:** the numerical value in this address is used as the function code of object to handle the corresponding operation.
2899 +1. **DLL file name: **Select needed dll file (i.e. dll files provided by users)
2900 +1. **Custom address:** users can add some function address to cooperate with dll file to complete other operations
2886 2886  
2887 2887  **✎Note:**
2888 2888  
... ... @@ -2890,6 +2890,6 @@
2890 2890  
2891 2891  Required documents: two XXXXXX.dll files and an document.
2892 2892  
2893 -* One dll file is used on PC and should be put under the dll_pc folder in the software installation directory.
2908 +* One dll file is used in PC and should be put under the dll_pc folder in the software installation directory.
2894 2894  * One dll file is used in HMI and should be put under the dll_hmi folder in the software installation directory.
2895 2895  * A document for illustrating the dll files.
XWiki.XWikiComments[0]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -{{mention reference="XWiki.Roy" style="FULL_NAME" anchor="XWiki-Roy-1tuen8"/}} {{mention reference="XWiki.admin" style="FULL_NAME" anchor="XWiki-admin-v9dwdf"/}} this is test message
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:16:52.686
XWiki.XWikiComments[1]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -{{mention reference="XWiki.admin" style="FULL_NAME" anchor="XWiki-admin-54p1l2"/}} hi
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:20:52.190
XWiki.XWikiComments[2]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -{{mention reference="XWiki.Roy" style="FULL_NAME" anchor="XWiki-Roy-xj75f6"/}} {{mention reference="XWiki.admin" style="FULL_NAME" anchor="XWiki-admin-le3bx2"/}} 这个应该可以了吧
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:23:11.227
XWiki.XWikiComments[3]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -hello
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:28:36.248
XWiki.XWikiComments[4]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -撒反对
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:31:30.668
XWiki.XWikiComments[5]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -{{mention reference="XWiki.admin" style="FULL_NAME" anchor="XWiki-admin-z27h71"/}} 最新的测试
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:38:03.653