Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
From version 72.1
edited by Jim(Forgotten)
on 2023/08/10 17:11
on 2023/08/10 17:11
Change comment:
There is no comment for this version
To version 81.1
edited by Jim(Forgotten)
on 2023/08/11 09:26
on 2023/08/11 09:26
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -774,6 +774,8 @@ 774 774 |(% style="width:277px" %)HDW18|(% style="width:113px" %)Word|(% style="width:291px" %)End Time: Minute 775 775 |(% style="width:277px" %)HDW19|(% style="width:113px" %)Word|(% style="width:291px" %)End Time: Second 776 776 777 +(% class="box infomessage" %) 778 +((( 777 777 **✎Note:** 778 778 779 779 * [Function address (20 words)] need to be HMI internal address; ... ... @@ -780,6 +780,9 @@ 780 780 * When the start time and end time of the query are enabled, if the end time is smaller than the start time, the system automatically swaps the start and end times to calculate the span of the query; 781 781 * After manually setting the start time and end time of the query, you need to manually update the data (the default will be automatically updated); 782 782 785 + 786 +))) 787 + 783 783 **Appearance** 784 784 785 785 (% style="text-align:center" %) ... ... @@ -929,7 +929,10 @@ 929 929 * ... 930 930 * 40=10 means this object display 10th page. 931 931 937 +(% class="box infomessage" %) 938 +((( 932 932 **✎Note:** Every page contains 50 records. 940 +))) 933 933 934 934 **Start Time** 935 935 ... ... @@ -1135,6 +1135,8 @@ 1135 1135 (% style="text-align:center" %) 1136 1136 [[image:6.Objects_html_ea2cd87aaa6600cd.gif||height="413" width="567" class="img-thumbnail"]] 1137 1137 1146 +(% class="box infomessage" %) 1147 +((( 1138 1138 (% class="wikigeneratedid" %) 1139 1139 **✎Note:** 1140 1140 ... ... @@ -1141,6 +1141,7 @@ 1141 1141 * If the file type is recipe file, modify the value of the address of "Select line" to control the selected line in the display list to the corresponding line. If another file type is selected, this address can only display the selected line (read-only mode). 1142 1142 * For ie series and ig series HMI, "system message" and "timeout alert" will be displayed in the top pop-up window. The options of them will no longer be displayed in the record. 1143 1143 * For the details, please refer to "[[Recipe>>https://docs.we-con.com.cn/bin/view/PIStudio/08.Basic%20Function/#HRecipe]]". 1154 +))) 1144 1144 1145 1145 == **File list** == 1146 1146 ... ... @@ -1165,7 +1165,10 @@ 1165 1165 ** ... 1166 1166 ** If 40=10, the 10th row of object is selected. 1167 1167 1179 +(% class="box infomessage" %) 1180 +((( 1168 1168 ✎**Note: **When the file type is Recipe File, modify the address value to control the selected line of the list to jump to the corresponding line; for other file types, this address only has the effect of displaying line No. 1182 +))) 1169 1169 1170 1170 * **Folder name address:** This is for setting recipe file name, in advance recipe mode. 1171 1171 ... ... @@ -1212,8 +1212,10 @@ 1212 1212 (% style="text-align:center" %) 1213 1213 [[image:6.Objects_html_a68643b928e3930.gif||class="img-thumbnail"]] 1214 1214 1215 -(% class="wikigeneratedid" %) 1229 +(% class="box infomessage" %) 1230 +((( 1216 1216 ✎**Note: **For the details, please refer to "[[Recipe>>https://docs.we-con.com.cn/bin/view/PIStudio/08.Basic%20Function/#HRecipe]]". 1232 +))) 1217 1217 1218 1218 == **XY plot** == 1219 1219 ... ... @@ -1324,7 +1324,10 @@ 1324 1324 1325 1325 The Disc Record displays the data from data source in the form of a disc curve. 1326 1326 1343 +(% class="box infomessage" %) 1344 +((( 1327 1327 **✎Note: **This function are only supported by HMI+, i series, ie series and ig series. 1346 +))) 1328 1328 1329 1329 **Source** 1330 1330 ... ... @@ -1338,7 +1338,10 @@ 1338 1338 ** **History**: It is in data record area configured by data record. Multiple record groups could be configured, and each record group has multiple channels. 1339 1339 ** **Real Time**: It is in Real-time trend chart configured by data record. Multiple record groups could be configured, and each record group has multiple curve numbers. 1340 1340 1360 +(% class="box infomessage" %) 1361 +((( 1341 1341 **✎Note: **There must be one of settings (Data record and real-time trend chart) in configurations, otherwise there will be no data in curve buffer. 1363 +))) 1342 1342 1343 1343 * **Curve No.**: The number of curves is the same as the number of channels in the record group. A maximum of 8 curves could be displayed. After selecting the curve to be displayed, it can set the scale range and scale color of each curve. 1344 1344 * **Enable**: After selecting the corresponding curve number in the status bar and enabling the curve, set different curve styles and colors according to your needs, then select the channel number in the data buffer, and finally set the data range. ... ... @@ -1372,7 +1372,10 @@ 1372 1372 **Function start Address**: Open the sub-screen of the data record query, and the system can automatically allocate the object address of the query screen according to the configured address. When using this component, it will automatically generate buttons for four direction, you can use these four control keys to view the data record display, and automatically create a new sub-screen based on the function start address, the content of the sub-screen is the query setting for span and start time. 1373 1373 When two objects use one function screen at the same time, if the function addresses of the two object are the same, changing the built-in screen will affect the operation of the two display object at the same time. If the function addresses of the two objects are different, the second object with the built-in screen can be displayed normally, and the first object will be displayed abnormally. 1374 1374 1397 +(% class="box infomessage" %) 1398 +((( 1375 1375 **✎Note: ** When copying Data record display, it is recommended to create a new "function screen" to avoid repeated calls that may cause abnormal functions. 1400 +))) 1376 1376 1377 1377 **Start time**: Set the start time and conditions for data viewing. 1378 1378 ... ... @@ -2382,6 +2382,8 @@ 2382 2382 2383 2383 Coordinate displays the object location on the screen, and size is the length and width of the object. 2384 2384 2410 +(% class="box infomessage" %) 2411 +((( 2385 2385 **✎Note:** 2386 2386 2387 2387 * When using USB camera, HD USB camera is not recommended, which is limited by the resolution displayed by HMI itself. ... ... @@ -2393,8 +2393,11 @@ 2393 2393 ** REB-USB 100W07M (supports 720p) 2394 2394 ** WX152HD (supports 720p) 2395 2395 ** RMONCAM G200 (supports 720p) 2396 -** ASHU S300 (640*480) 2423 +** ASHU S300 (640*480 2424 +))) 2397 2397 2426 +* \\ 2427 + 2398 2398 == **Camera control** == 2399 2399 2400 2400 This is for control camera; This object need to be used with camera display object. ... ... @@ -2884,6 +2884,8 @@ 2884 2884 1. **DLL file name: **Select needed dll file. (i.e. dll files provided by users) 2885 2885 1. **Custom address:** Users can add some function address to cooperate with dll file to complete other operations. 2886 2886 2917 +(% class="box infomessage" %) 2918 +((( 2887 2887 **✎Note:** 2888 2888 2889 2889 This is a custom-made object that requires the cooperation of WECON software engineers. ... ... @@ -2893,3 +2893,4 @@ 2893 2893 * One dll file is used on PC and should be put under the dll_pc folder in the software installation directory. 2894 2894 * One dll file is used in HMI and should be put under the dll_hmi folder in the software installation directory. 2895 2895 * A document for illustrating the dll files. 2928 +)))