Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
From version 75.1
edited by Jim(Forgotten)
on 2023/08/10 17:21
on 2023/08/10 17:21
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.test - Content
-
... ... @@ -458,8 +458,6 @@ 458 458 * **Run times: **Configuration sub-function execute times. 0 means unlimited times. 459 459 * **Break:** Stop executing sub-function when trigger address is ON. 460 460 461 -(% class="box infomessage" %) 462 -((( 463 463 ✎**Note:** 464 464 465 465 * Nested patterns of object cycle and sub-function cycles are as follows. ... ... @@ -469,7 +469,6 @@ 469 469 ** If the object cycle ends later than the sub-function cycle, the sub-function cycle would be triggered again. 470 470 ** If the main cycle is triggered again before it finishes, then the main cycle is executed immediately when clicked and only one more time. 471 471 * For [[text>>https://docs.we-con.com.cn/bin/view/PIStudio/7.Library/#HText]]/[[graphics>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HGraphic]]/[[security>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HSecurity]]/[[animations>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HAnimation]], see the "[[Bit Switch>>path:https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 472 -))) 473 473 474 474 == Slider switch == 475 475 ... ... @@ -774,8 +774,6 @@ 774 774 |(% style="width:277px" %)HDW18|(% style="width:113px" %)Word|(% style="width:291px" %)End Time: Minute 775 775 |(% style="width:277px" %)HDW19|(% style="width:113px" %)Word|(% style="width:291px" %)End Time: Second 776 776 777 -(% class="box infomessage" %) 778 -((( 779 779 **✎Note:** 780 780 781 781 * [Function address (20 words)] need to be HMI internal address; ... ... @@ -782,9 +782,6 @@ 782 782 * When the start time and end time of the query are enabled, if the end time is smaller than the start time, the system automatically swaps the start and end times to calculate the span of the query; 783 783 * After manually setting the start time and end time of the query, you need to manually update the data (the default will be automatically updated); 784 784 785 - 786 -))) 787 - 788 788 **Appearance** 789 789 790 790 (% style="text-align:center" %) ... ... @@ -2387,8 +2387,6 @@ 2387 2387 2388 2388 Coordinate displays the object location on the screen, and size is the length and width of the object. 2389 2389 2390 -(% class="box infomessage" %) 2391 -((( 2392 2392 **✎Note:** 2393 2393 2394 2394 * When using USB camera, HD USB camera is not recommended, which is limited by the resolution displayed by HMI itself. ... ... @@ -2400,11 +2400,8 @@ 2400 2400 ** REB-USB 100W07M (supports 720p) 2401 2401 ** WX152HD (supports 720p) 2402 2402 ** RMONCAM G200 (supports 720p) 2403 -** ASHU S300 (640*480 2404 -))) 2393 +** ASHU S300 (640*480) 2405 2405 2406 -* \\ 2407 - 2408 2408 == **Camera control** == 2409 2409 2410 2410 This is for control camera; This object need to be used with camera display object. ... ... @@ -2894,8 +2894,6 @@ 2894 2894 1. **DLL file name: **Select needed dll file. (i.e. dll files provided by users) 2895 2895 1. **Custom address:** Users can add some function address to cooperate with dll file to complete other operations. 2896 2896 2897 -(% class="box infomessage" %) 2898 -((( 2899 2899 **✎Note:** 2900 2900 2901 2901 This is a custom-made object that requires the cooperation of WECON software engineers. ... ... @@ -2905,4 +2905,3 @@ 2905 2905 * One dll file is used on PC and should be put under the dll_pc folder in the software installation directory. 2906 2906 * One dll file is used in HMI and should be put under the dll_hmi folder in the software installation directory. 2907 2907 * A document for illustrating the dll files. 2908 -)))