Changes for page 05 Objects

Last modified by Jett on 2025/07/04 09:41

From version 77.1
edited by Jim(Forgotten)
on 2023/08/10 17:26
Change comment: There is no comment for this version
To version 72.1
edited by Jim(Forgotten)
on 2023/08/10 17:11
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -774,8 +774,6 @@
774 774  |(% style="width:277px" %)HDW18|(% style="width:113px" %)Word|(% style="width:291px" %)End Time: Minute
775 775  |(% style="width:277px" %)HDW19|(% style="width:113px" %)Word|(% style="width:291px" %)End Time: Second
776 776  
777 -(% class="box infomessage" %)
778 -(((
779 779  **✎Note:**
780 780  
781 781  * [Function address (20 words)] need to be HMI internal address;
... ... @@ -782,9 +782,6 @@
782 782  * When the start time and end time of the query are enabled, if the end time is smaller than the start time, the system automatically swaps the start and end times to calculate the span of the query;
783 783  * After manually setting the start time and end time of the query, you need to manually update the data (the default will be automatically updated);
784 784  
785 -
786 -)))
787 -
788 788  **Appearance**
789 789  
790 790  (% style="text-align:center" %)
... ... @@ -934,10 +934,7 @@
934 934  * ...
935 935  * 40=10 means this object display 10th page.
936 936  
937 -(% class="box infomessage" %)
938 -(((
939 939  **✎Note:** Every page contains 50 records.
940 -)))
941 941  
942 942  **Start Time**
943 943  
... ... @@ -1173,10 +1173,7 @@
1173 1173  ** ...
1174 1174  ** If 40=10, the 10th row of object is selected.
1175 1175  
1176 -(% class="box infomessage" %)
1177 -(((
1178 1178  ✎**Note: **When the file type is Recipe File, modify the address value to control the selected line of the list to jump to the corresponding line; for other file types, this address only has the effect of displaying line No.
1179 -)))
1180 1180  
1181 1181  * **Folder name address:** This is for setting recipe file name, in advance recipe mode.
1182 1182  
... ... @@ -2393,8 +2393,6 @@
2393 2393  
2394 2394  Coordinate displays the object location on the screen, and size is the length and width of the object.
2395 2395  
2396 -(% class="box infomessage" %)
2397 -(((
2398 2398  **✎Note:**
2399 2399  
2400 2400  * When using USB camera, HD USB camera is not recommended, which is limited by the resolution displayed by HMI itself.
... ... @@ -2406,11 +2406,8 @@
2406 2406  ** REB-USB 100W07M (supports 720p)
2407 2407  ** WX152HD (supports 720p)
2408 2408  ** RMONCAM G200 (supports 720p)
2409 -** ASHU S300 (640*480
2410 -)))
2396 +** ASHU S300 (640*480)
2411 2411  
2412 -* \\
2413 -
2414 2414  == **Camera control** ==
2415 2415  
2416 2416  This is for control camera; This object need to be used with camera display object.
... ... @@ -2900,8 +2900,6 @@
2900 2900  1. **DLL file name: **Select needed dll file. (i.e. dll files provided by users)
2901 2901  1. **Custom address:** Users can add some function address to cooperate with dll file to complete other operations.
2902 2902  
2903 -(% class="box infomessage" %)
2904 -(((
2905 2905  **✎Note:**
2906 2906  
2907 2907  This is a custom-made object that requires the cooperation of WECON software engineers.
... ... @@ -2911,4 +2911,3 @@
2911 2911  * One dll file is used on PC and should be put under the dll_pc folder in the software installation directory.
2912 2912  * One dll file is used in HMI and should be put under the dll_hmi folder in the software installation directory.
2913 2913  * A document for illustrating the dll files.
2914 -)))