Changes for page 05 Objects

Last modified by Jett on 2025/07/04 09:41

From version 78.1
edited by Jim(Forgotten)
on 2023/08/10 17:30
Change comment: There is no comment for this version
To version 41.2
edited by Karen
on 2023/05/24 15:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Jim
1 +XWiki.Karen
Content
... ... @@ -458,8 +458,6 @@
458 458  * **Run times: **Configuration sub-function execute times. 0 means unlimited times.
459 459  * **Break:** Stop executing sub-function when trigger address is ON.
460 460  
461 -(% class="box infomessage" %)
462 -(((
463 463  ✎**Note:**
464 464  
465 465  * Nested patterns of object cycle and sub-function cycles are as follows.
... ... @@ -469,7 +469,6 @@
469 469  ** If the object cycle ends later than the sub-function cycle, the sub-function cycle would be triggered again.
470 470  ** If the main cycle is triggered again before it finishes, then the main cycle is executed immediately when clicked and only one more time.
471 471  * For [[text>>https://docs.we-con.com.cn/bin/view/PIStudio/7.Library/#HText]]/[[graphics>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HGraphic]]/[[security>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HSecurity]]/[[animations>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HAnimation]], see the "[[Bit Switch>>path:https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]".
472 -)))
473 473  
474 474  == Slider switch ==
475 475  
... ... @@ -774,8 +774,6 @@
774 774  |(% style="width:277px" %)HDW18|(% style="width:113px" %)Word|(% style="width:291px" %)End Time: Minute
775 775  |(% style="width:277px" %)HDW19|(% style="width:113px" %)Word|(% style="width:291px" %)End Time: Second
776 776  
777 -(% class="box infomessage" %)
778 -(((
779 779  **✎Note:**
780 780  
781 781  * [Function address (20 words)] need to be HMI internal address;
... ... @@ -782,9 +782,6 @@
782 782  * When the start time and end time of the query are enabled, if the end time is smaller than the start time, the system automatically swaps the start and end times to calculate the span of the query;
783 783  * After manually setting the start time and end time of the query, you need to manually update the data (the default will be automatically updated);
784 784  
785 -
786 -)))
787 -
788 788  **Appearance**
789 789  
790 790  (% style="text-align:center" %)
... ... @@ -934,10 +934,7 @@
934 934  * ...
935 935  * 40=10 means this object display 10th page.
936 936  
937 -(% class="box infomessage" %)
938 -(((
939 939  **✎Note:** Every page contains 50 records.
940 -)))
941 941  
942 942  **Start Time**
943 943  
... ... @@ -1097,24 +1097,24 @@
1097 1097  (% style="text-align:center" %)
1098 1098  [[image:6.Objects_html_858d4ec965274b8a.gif||class="img-thumbnail"]]
1099 1099  
1100 -* **File type: **There are more than one function in this object, this is for selecting function, select [System message], when event occurs, it displays prompt messages automatically.
1089 +* **File type: **There are more than one functions in this object, this is for selecting function, select [System message],when event occurs, it displays prompt messages automatically.
1101 1101  * **Select line: **Set address for select row.
1102 1102  
1103 1103  **Address Control**
1104 1104  
1105 -* **Start group: **Control displaying start from specified row, which means display from specified group.
1106 -* For example, set 40
1094 +* **Start group: **control displaying start fromspecified row, which means display from specified group.
1095 +* For example set 40,
1107 1107  ** If 40=1, Start from first row (first group).
1108 1108  ** If 40=2, Start from second row (second group).
1109 1109  ** ...
1110 1110  ** If 40=10, Start from 10th row (10th group).
1111 1111  * **Group number address: **Control the number of rows displayed;
1112 -* For example, set 410
1101 +* For example set 410,
1113 1113  ** If 410=1, this object only displays 1 row (1 group).
1114 1114  ** If 410=2, this object displays 2 rows (2 groups).
1115 1115  ** ...
1116 1116  ** If 410=10, this object displays 10 rows (10 groups).
1117 -* **Start address: **Control displaying start from specified column, which means display from specified member.
1106 +* **Start address: **Control displaying start fromspecified column, which means display from specified member.
1118 1118  * For example, set 420,
1119 1119  ** If 420=1, Start from first column (first member).
1120 1120  ** If 420=2, Start from second column (second member).
... ... @@ -1143,21 +1143,18 @@
1143 1143  (% style="text-align:center" %)
1144 1144  [[image:6.Objects_html_ea2cd87aaa6600cd.gif||height="413" width="567" class="img-thumbnail"]]
1145 1145  
1146 -(% class="box infomessage" %)
1147 -(((
1148 1148  (% class="wikigeneratedid" %)
1149 1149  **✎Note:**
1150 1150  
1151 1151  * If the file type is recipe file, modify the value of the address of "Select line" to control the selected line in the display list to the corresponding line. If another file type is selected, this address can only display the selected line (read-only mode).
1152 -* For ie series and ig series HMI, "system message" and "timeout alert" will be displayed in the top pop-up window. The options of them will no longer be displayed in the record.
1139 +* For ie series and ig series HMI, "system message" and "timeout alert" will be displayed in the top pop-up window. They options of them will no longer be displayed in the record.
1153 1153  * For the details, please refer to "[[Recipe>>https://docs.we-con.com.cn/bin/view/PIStudio/08.Basic%20Function/#HRecipe]]".
1154 -)))
1155 1155  
1156 1156  == **File list** ==
1157 1157  
1158 1158  "File List" displays the recipe file name of the current project in the form of table in HMI. If there is no recipe file in the project, the table of the object is empty. (Table and trend chart objects currently only support Song Typeface, other fonts you set will not work.
1159 1159  
1160 -Recipe files in "Flash", and also shows custom folder information.
1146 +recipe files in "Flash", and also shows custom folder information.
1161 1161  
1162 1162  **Function (Recipe File)**
1163 1163  
... ... @@ -1167,7 +1167,7 @@
1167 1167  (% style="text-align:center" %)
1168 1168  [[image:6.Objects_html_66cd30b2b962a04e.gif||class="img-thumbnail"]]
1169 1169  
1170 -* **File type: **[Recipe File] is for displaying recipe files in Flash.
1156 +* **File type: **[Recipe File] is for display recipe files in Flash.
1171 1171  * **Folder name:** This is located to recipe function setting.
1172 1172  * **Select line:** Select one line in list and display its line No. in this address.
1173 1173  * For example, set 40,
... ... @@ -1176,10 +1176,7 @@
1176 1176  ** ...
1177 1177  ** If 40=10, the 10th row of object is selected.
1178 1178  
1179 -(% class="box infomessage" %)
1180 -(((
1181 -✎**Note: **When the file type is Recipe File, modify the address value to control the selected line of the list to jump to the corresponding line; for other file types, this address only has the effect of displaying line No.
1182 -)))
1165 +✎**Note: **When the file type is Recipe File, modify the address value to control the selected line of the list to jump to the corresponding line; for other file types, this address only has the effect of displaying the line No.
1183 1183  
1184 1184  * **Folder name address:** This is for setting recipe file name, in advance recipe mode.
1185 1185  
... ... @@ -1204,9 +1204,9 @@
1204 1204  (% style="text-align:center" %)
1205 1205  [[image:6.Objects_html_dc49c7d7148792b3.gif||class="img-thumbnail"]]
1206 1206  
1207 -Function address includes copy, paste, delete, and rename. And HMI automatically assigns the functions to bit addresses.
1190 +Function address includes copy, past, delete and rename. And HMI automatically assigns the functions to bit addresses.
1208 1208  
1209 -For example, if the function address is HDW 90, the detailed information is below.
1192 +For example, if the function address is HDW 90, the detailed information as below.
1210 1210  
1211 1211  (% class="table-bordered" %)
1212 1212  |**Address**|**Address type**|**Object type**|**Function**
... ... @@ -1349,15 +1349,15 @@
1349 1349  ** **History**: Historical data can be queried.
1350 1350  ** **Real Time**: Only real-time data is displayed.
1351 1351  * **Curve Buffer**
1352 -** **History**: Iis in data record area configured by data record. Multiple record groups could be configured, and each record group has multiple channels.
1335 +** **History**: Ii is in data record area configured by data record. Multiple record groups could be configured, and each record group has multiple channels.
1353 1353  ** **Real Time**: It is in Real-time trend chart configured by data record. Multiple record groups could be configured, and each record group has multiple curve numbers.
1354 1354  
1355 -**✎Note: **There must be one of settings (Data record and real-time trend chart) in configurations, otherwise there will be no data in curve buffer.
1338 +**✎Note: **There must be one of settings (Data record and real-time trend chart) in configurations, otherwise there will no data in curve buffer.
1356 1356  
1357 -* **Curve No.**: The number of curves is the same as the number of channels in the record group. A maximum of 8 curves could be displayed. After selecting the curve to be displayed, it can set the scale range and scale color of each curve.
1358 -* **Enable**: After selecting the corresponding curve number in the status bar and enabling the curve, set different curve styles and colors according to your needs, then select the channel number in the data buffer, and finally set the data range.
1340 +* **Curve No.**: The number of curves is the same as the number of channels in the record group. A maximum of 8 curves could be displayed.After selecting the curve to be displayed, it can set the scale range and scale color of each curve.
1341 +* **Enable**: After selecting the corresponding curve number in the status bar and enable the curve, set different curve styles and colors according to your needs, then select the channel number in the data buffer, and finally set the data range.
1359 1359  * **Data Range: **Directly set the maximum and minimum values of the displayed graph. If the box "Variable Range" is checked, the set data is read from the filled address. The data format of the address is set as needed, and the length of the variable address is related to the set data format.
1360 -* **Display Scale Value: **Display the value of disc record. The font color could be changed.
1343 +* **Display Scale Value: **Display the value of disc record. The font color could be changed
1361 1361  
1362 1362  **Appearance**
1363 1363  
... ... @@ -1364,9 +1364,9 @@
1364 1364  (% style="text-align:center" %)
1365 1365  [[image:6-3DiscRecordConfigAppearen.png||class="img-thumbnail"]]
1366 1366  
1367 -1. **Circular Axis Scale**: Number of scale intervals in the direction of the circular axis. The range is 1 to 10.
1368 -1. **Start Position**: The starting position to draw the curve: top, bottom, left, and right.
1369 -1. **Rotary Axis Scale**: Number of scale intervals in the direction of the axis of rotation. The range is 4, 6, and 12.
1350 +1. **Circular Axis Scale**: Number of scale intervals in the direction of the circular axis. The range is1 to10.
1351 +1. **Start Position**: The starting position to draw the curve: top, bottom, left and right.
1352 +1. **Rotary Axis Scale**: Number of scale intervals in the direction of the axis of rotation. The range is 4, 6 and 12.
1370 1370  1. **Inner Circle Size**: Ratio of the inner circle to the outer circle.
1371 1371  1. **Scale Style**: The way the scale is displayed, style 0 represents adaptive display, and style 1 represents forward display.
1372 1372  1. **Background Color**: Appearance background color.
... ... @@ -1402,7 +1402,7 @@
1402 1402  
1403 1403  == **Pointer meter** ==
1404 1404  
1405 -The meter responds to change in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1388 +The meter responds to changes in the value of the indicated word address by means of a dial and a pointer. The meter looks very similar to the actual meter.
1406 1406  
1407 1407  (% style="text-align:center" %)
1408 1408  [[image:image-20220805161001-1.jpeg]]
... ... @@ -1417,13 +1417,13 @@
1417 1417  * 32-bit signed decimal
1418 1418  * 32-bit unsigned decimal
1419 1419  
1420 -**Digits setting:** Set directly the maximum and the minimum. Only when the floating point number is selected, can the maximum and minimum value be with a decimal point, and other data formats can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.
1403 +**Digits setting:** set directly the maximum and the minimum. Only when the floating point number is selected, can the the maximum and minimum value be with a decimal point, and other data format can't be with a decimal point. If the value is read by the address, then select "variable limits", and fill in the address.
1421 1421  
1422 1422  * **Min angle and max angle:** Data range, if data beyond range will be not inputted.
1423 1423  
1424 -**Variable limits:** When checked, low limit address and high limit address could be edit showed below;
1407 +**Variable limits:** when checked, low limit address and high limit address could be edit showed below;
1425 1425  
1426 -**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select according to needs.
1409 +**Show meter background**: This is for setting meter background. When not checked, the background color is transparent; When checked, there are four styles of pointer meter to select it according to needs.
1427 1427  
1428 1428  **Show pointer**: When not checked, the pointer is not displayed; When checked, you could set the style and color of pointer.
1429 1429  
... ... @@ -1431,15 +1431,15 @@
1431 1431  
1432 1432  **Show scale**: Display the scale on the object to observe the value. You need to set major scale, minor scale and scale value.
1433 1433  
1434 -**Meter Type:** It sets the angle between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1417 +**Meter Type:** It sets the angel between the maximum and minimum value. It provides 7 kinds of styles, they are 180°, 210°, 240°, 270°, 300°, 330° and 360°.
1435 1435  
1436 1436  **Start angle: **It sets the position where the minimum value is displayed.
1437 1437  
1438 -**Position&size:** Set the position of the object on the screen and the size of the object. The object is displayed as square. If the width or the height of the object is changed, the other data will also be changed.
1421 +**Position&size:** Set the position of the object in the screen and the size of the object. The object is displayed as square. If the width or the height of the object is changed, the other data will also be changed.
1439 1439  
1440 1440  **Result**
1441 1441  
1442 -When configuration is completed, the object is shown below picture when HMI is running.
1425 +When configuration is completed, the object is shown as below picture when HMI is running.
1443 1443  
1444 1444  (% style="text-align:center" %)
1445 1445  [[image:6.Objects_html_1b8e24a5065cf96a.gif||class="img-thumbnail"]]
... ... @@ -1622,10 +1622,13 @@
1622 1622  
1623 1623  == **QR Code** ==
1624 1624  
1608 +**Introduction**
1609 +
1625 1625  It is similar to the universal QR code. You could scan this object to get the connection or content, but it provides content settings for QR code.
1626 1626  
1627 1627  **Description**
1628 1628  
1614 +
1629 1629  (% style="text-align:center" %)
1630 1630  [[image:6.Objects_html_4cf155075ac97d16.gif||class="img-thumbnail"]]
1631 1631  
... ... @@ -1637,7 +1637,7 @@
1637 1637  **✎Note:**
1638 1638  
1639 1639  * HMI machine ID address: HSW10494 ~~ HSW10558.
1640 -* So if user want to use QR code to display machine ID on project screen, please check "Variable QR", and set address is HSW10494.
1626 +* So if user want to use QR code to display machine ID in project screen, please check "Variable QR", and set address is HSW10494.
1641 1641  * When scanning the QR code by APP to monitor HMI, the default access password is 888888.
1642 1642  
1643 1643  == **Picture** ==
... ... @@ -1663,9 +1663,9 @@
1663 1663  
1664 1664  This is advanced function of picture object; user can change display picture when HMI is running. The supported formats are bmp, jpg, png, jpeg. This feature is unavailable for offline and online simulation.
1665 1665  
1666 -1. **Root: **Set the save location of the picture, which can be set to U disk,SD card,but could not be set to Flash.
1652 +1. **Root: **Set the save location of the picture,which can be set to U disk,SD card,but could not be set to Flash.
1667 1667  1. **Folder: **Set the name of the folder where the picture is located.The folder name can be up to 31 characters. (Note:The picture must be stored in the U disk folder and cannot be stored in the root directory of the U disk.)
1668 -1. **File address: **16 consecutive addresses enter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed.
1654 +1. **File address: **16 consecutive addressesenter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed.
1669 1669  
1670 1670  ✎**Note:** 
1671 1671  
... ... @@ -1698,7 +1698,7 @@
1698 1698  * **Min. angle:** It sets the starting angle of rotation (Valid in auto-rotation mode).
1699 1699  * **Max. angle:** It sets the ending angle of rotation (Valid in auto-rotation mode).
1700 1700  
1701 -**Rotation angle: **The rotating angle is determined by designated address;
1687 +**Rotation angle: **the rotating angle is determined by designated address;
1702 1702  
1703 1703  **Rotation center**: It shows the rotation center coordinates;
1704 1704  
... ... @@ -1712,7 +1712,7 @@
1712 1712  
1713 1713  **Enable auto-spin: **When the address is set to ON, the picture will rotate automatically.
1714 1714  
1715 -**Hide:** Control the hiding status of the object through the status of the control bit address. The hiding mode can be divided into hide when OFF and hide when ON.
1701 +**Hide:** control the hiding status of the object through the status of the control bit address. The hiding mode can be divided into hide when OFF and hide when ON.
1716 1716  
1717 1717  == **Drop-down List** ==
1718 1718  
... ... @@ -1728,18 +1728,18 @@
1728 1728  **1) Edit**
1729 1729  
1730 1730  1. **Read Address:** The data from designated address will be displayed.
1731 -1. **Same read-write address:** Configure "Write Address" as the same as "Read Address".
1732 -1. **Write Address: **Write data to designated address. The address can be different from "Read Address".
1717 +1. **Same read-write address:** Configure "Write Address" is the same as "Read Address".
1718 +1. **Write Address: **Write data to designated address. The address can be different "Read Address".
1733 1733  
1734 1734  **2) Format**
1735 1735  
1736 -Set data format for object, it provides 16-bit unsigned decimal,16-bit BCD, 16-bit unsigned decimal, 32-bit BCD, 32-bit unsigned decimal, and 32-bit unsigned decimal.
1722 +Set data format for object, it provides 16-bit unsigned decimal,16-bit BCD, 16-bit unsigned decimal, 32-bit BCD, 32-bit unsigned decimal and 32-bit unsigned decimal.
1737 1737  
1738 1738  **3) State count**
1739 1739  
1740 1740  It could set the total number to display in the drop-list and supports up to 128 states (1 to 128). The default value of state is corresponding to the number of states. (State 1 corresponding to value 1). You can also click "state values" to set it according to your needs.
1741 1741  
1742 -**State value: **User can set different values to correspond to different states, the setting window as below figure shows.
1728 +**State value: **You can set different values to correspond to different states, the setting window as below figure shows.
1743 1743  
1744 1744  (% style="text-align:center" %)
1745 1745  [[image:6.Objects_html_da9a6696f320b427.gif||class="img-thumbnail"]]
... ... @@ -1783,12 +1783,12 @@
1783 1783  
1784 1784  **3) Read state text from address**
1785 1785  
1786 -1. **Text start address: **The first address of occupied multiple consecutive addresses. Address length: [Text length/2] *[state number +1].
1772 +1. **Text start address: **the first address of occupied multiple consecutive addresses. Address length: [Text length/2] *[state number +1].
1787 1787  
1788 1788  * For example: 10 states, the address length= (10/2) *(10+1) =55. It set HDW100 as start address, so the HDW100-HDW104 stores the currently selected text content, the HDW105-HDW109 displays the text in the first state, the HDW110-HDW114 displays the second, and so on.
1789 1789  
1790 1790  (% start="2" %)
1791 -1. **Refresh: **The drop-down list status value is updated according to the text address content. The drop-down list is not updated immediately, when the data in the text address change is completed, only the refresh is triggered, it will update.
1777 +1. **Refresh:**The drop-down list status value is updated according to the text address content.The drop-down list is not updated immediately, when the data in the text address change is completed, only the refresh is triggered, it will update.
1792 1792  
1793 1793  == **Camera display** ==
1794 1794  
... ... @@ -1800,8 +1800,6 @@
1800 1800  
1801 1801  === **IP Camera** ===
1802 1802  
1803 -**(1) General**
1804 -
1805 1805  (% style="text-align:center" %)
1806 1806  [[image:6.Objects_html_2bc22bd50bf65eb.gif||class="img-thumbnail"]]
1807 1807  
... ... @@ -2211,7 +2211,7 @@
2211 2211  The camera configured via ip only supports, turn on, turn off, screenshot basic functions.
2212 2212  )))
2213 2213  
2214 -**EZVIZ Cloud Description**
2198 +**EZVIZ Cloud Descirption**
2215 2215  
2216 2216  (% style="text-align:center" %)
2217 2217  [[image:企业微信截图_1673081149790.png]]
... ... @@ -2317,23 +2317,23 @@
2317 2317  |=(% style="width: 129px;" %)60020|(% style="width:366px" %)Unsupport this command|(% style="width:531px" %)Confirm the device whether supports this operation or not
2318 2318  
2319 2319  (% class="wikigeneratedid" %)
2320 -**Default Configuration**: Enable the default configuration, the initialization of the EZVIZ cloud camera display components will use the default configuration for binding, the screen can also be modified through the function address configuration information; do not enable the default configuration, the default initial configuration of the EZVIZ cloud camera display components are empty.
2304 +**Default Configuration**:Enable the default configuration, the initialization of the EZVIZ cloud camera display components will use the default configuration for binding, the screen can also be modified through the function address configuration information; do not enable the default configuration, the default initial configuration of the EZVIZ cloud camera display components are empty.
2321 2321  
2322 2322  **In the default configuration, the following are required:**
2323 2323  
2324 -**AppKey**: EZVIZ cloud application information AppKey, up to 32 characters in length, only letters and numbers can be entered, which can be obtained through the EZVIZ cloud open platform.
2325 -**Secret**: EZVIZ cloud application information Secret, up to 32 characters in length, only letters and numbers can be entered, available through the EZVIZ cloud open platform.
2326 -**Channel number**: EZVIZ cloud device source channel number, 1~~65535, no special modification, generally defaulted to 1, which can be obtained by viewing the EZVIZ cloud client software.
2308 +**AppKey**:EZVIZ cloud application information AppKey, up to 32 characters in length, only letters and numbers can be entered, which can be obtained through the EZVIZ cloud open platform.
2309 +**Secret**:EZVIZ cloud application information Secret, up to 32 characters in length, only letters and numbers can be entered, available through the EZVIZ cloud open platform.
2310 +**Channel number**:EZVIZ cloud device source channel number, 1~~65535, no special modification, generally defaulted to 1, which can be obtained by viewing the EZVIZ cloud client software.
2327 2327  
2328 -**S/N: **EZVIZ cloud device serial number, 0 to 80 characters in length, only letters, numbers and "-" can be entered, which can be obtained through the device information.
2312 +**S/N:**EZVIZ cloud device serial number, 0 to 80 characters in length, only letters, numbers and "-" can be entered, which can be obtained through the device information.
2329 2329  
2330 2330  
2331 2331  **In the default configuration, the following are optional:**
2332 2332  
2333 -**IP**: EZVIZ cloud device IP, which can be obtained by viewing the EZVIZ cloud client software.
2317 +**IP**:EZVIZ cloud device IP, which can be obtained by viewing the EZVIZ cloud client software.
2334 2334  
2335 -**RTSP Port**: EZVIZ cloud device source rtsp port number, range 0~~65535, no special modification, generally default to 554, can be obtained by viewing the EZVIZ cloud client software.
2336 -**Verification Code**: EZVIZ cloud device authentication code, up to 32 characters in length, obtainable through device information.
2319 +**RTSP Port**:EZVIZ cloud device source rtsp port number, range 0~~65535, no special modification, generally default to 554, can be obtained by viewing the EZVIZ cloud client software.
2320 +**Verification Code**:EZVIZ cloud device authentication code, up to 32 characters in length, obtainable through device information.
2337 2337  
2338 2338  {{info}}
2339 2339  **✎Note: **The required content in the configuration only supports remote monitoring when the camera screen can be displayed, if there is a demand for the screen side can also display the camera screen, user need to fill in the optional content in the configuration.
... ... @@ -2341,8 +2341,6 @@
2341 2341  
2342 2342  === **USB Camera** ===
2343 2343  
2344 -**(1) General**
2345 -
2346 2346  (% style="text-align:center" %)
2347 2347  [[image:6.Objects_html_6d926ea40f8267c.gif||class="img-thumbnail"]]
2348 2348  
... ... @@ -2359,7 +2359,7 @@
2359 2359  |(% style="width:144px" %)1|(% style="width:700px" %)Enable the screenshot function
2360 2360  |(% style="width:144px" %)2|(% style="width:700px" %)refresh camera display object
2361 2361  
2362 -**Camera state: **It shows the current camera states. It occupies a word address. Different value means different operations, as below table shows:
2344 +**Camera state: **It shows the current camera states. Itoccupies a word address. Different value means different operations, as below table shows:
2363 2363  
2364 2364  (% class="table-bordered" %)
2365 2365  |=**Value**|=**Operation**
... ... @@ -2380,11 +2380,11 @@
2380 2380  
2381 2381  The current screenshots are only allowed on the SD card. When the SD card does not exist the system will cache the latest 10 screenshots.
2382 2382  
2383 -**Picture name: **The name of the image is controlled by the address. The length of the file name is limited to 64 words. If the image name address is not set, it will be named according to the time and displayed as [YYYYMMDDHHMMSS.bmp] and screenshot format is [.bmp].
2365 +**Picture name: **The name of the image is controlled by the address.The length of the file name is limited to 64 words. If the image name address is not set, it will be named according to the time and displayed as [YYYYMMDDHHMMSS.bmp] and screenshot format is [.bmp].
2384 2384  
2385 2385  **4) Global screenshot**
2386 2386  
2387 -If this function is enabled, camera display object can perform the screenshot operation when HMI is running and save it as a . BMP image.
2369 +If this function is enable, camera display object can perform the screenshot operation when HMI is running and save it as a .BMP image.
2388 2388  
2389 2389  If this function is disabled, camera display object only performs the screenshot operation when it is displayed on screen.
2390 2390  
... ... @@ -2394,30 +2394,27 @@
2394 2394  
2395 2395  **6) Use resolution size**
2396 2396  
2397 -Coordinate displays the object location on the screen, and size is the length and width of the object.
2379 +Coordinate displays the object location in the screen, and size is the length and width of the object.
2398 2398  
2399 -(% class="box infomessage" %)
2400 -(((
2401 2401  **✎Note:**
2402 2402  
2403 2403  * When using USB camera, HD USB camera is not recommended, which is limited by the resolution displayed by HMI itself.
2404 -* When HMI is displayed horizontally, the USB camera screen displays normally. If select vertical display, USB camera can't display normally. (USB camera can only display normally when the display Angle of HMI is 0.)
2384 +* When HMI is displayed horizontally, the USB camera screen displays normally.If select vertical display, USB camera can't display normally. (USB camera can only display normally when the display Angle of HMI is 0.)
2405 2405  * One HMI is only allowed to connect with one USB camera device. There is only one USB camera display part in the whole project screen, and the camera display part is not allowed to be placed on the public screen (1002: common Windows).
2406 2406  * Sometimes the USB camera may lose the image because of the influence in the field, then we suggest to PI9000 HMI and the recommended USB camera model.
2407 -* All below USB camera model have been tested by WECON to ensure compatibility.
2387 +* All below USB camera model have been tested by WECON to ensure the compatibility.
2408 2408  * Currently, only PI8000 and PI9000 series support the USB camera function. Recommended USB cameras include:
2409 2409  ** REB-USB 100W07M (supports 720p)
2410 2410  ** WX152HD (supports 720p)
2411 2411  ** RMONCAM G200 (supports 720p)
2412 -** ASHU S300 (640*480
2413 -)))
2392 +** ASHU S300 (640*480)
2414 2414  
2415 -* \\
2416 -
2417 2417  == **Camera control** ==
2418 2418  
2419 -This is for control camera; This object need to be used with camera display object.
2396 +**Introduction**
2420 2420  
2398 +This is for control camera; this object need to be used with camera display object.
2399 +
2421 2421  **Description**
2422 2422  
2423 2423  (% style="text-align:center" %)
... ... @@ -2427,11 +2427,11 @@
2427 2427  
2428 2428  Read a string from designated system address, and then combine the instruction to control the camera image.
2429 2429  
2430 -When the dynamic control command is disabled, the complete camera control command is entered in order to display the camera contents.
2409 +When the dynamic control command is disabled, the complete camera control command be entered in order to display the camera contents.
2431 2431  
2432 2432  **2) Camera control instruction**
2433 2433  
2434 -This is for entering static instruction for camera so that users can operate camera when HMI running.
2413 +This is for enter static instruction for camera, so that users can operation camera when HMI running;
2435 2435  
2436 2436  **3) Control bit**
2437 2437  
... ... @@ -2443,7 +2443,7 @@
2443 2443  
2444 2444  == **Flow component** ==
2445 2445  
2446 -The flow components are mainly used to reflect the flow state in process flow production. User could set the style of flow components according to requirements.
2425 +The flow components are mainly used to reflect the flow state in process flow production. You could set the style of flow components according to requirements.
2447 2447  
2448 2448  **Description**
2449 2449  
... ... @@ -2463,9 +2463,9 @@
2463 2463  1. **Block width:** It sets block width of flow component.
2464 2464  1. **PipeFrn width: **It sets outer border width of flow component.
2465 2465  1. **Block length: **It sets block length of flow component.
2466 -1. **Transparence:** It sets transparence of flow component. (from opaque (0) to full transparence (100)). You could cooperate with transparence and other settings to meet display requirements.
2467 -1. **Ratio:** It sets the display ratio of block and background (Display density of the block in flow component).
2468 -1. **Speed:** It sets flow speed of the block during HMI running.
2445 +1. **Transparence:** It sets transparence of flow component.(from opaque (0) to full transparence (100)). You could cooperate with transparence and other settings to meet display requirements.
2446 +1. **Ratio:** It sets display ratio of block and background (Display density of the block in flow component).
2447 +1. **Speed:** It setsflow speed of the block during HMI running.
2469 2469  
2470 2470  **(3) Control**
2471 2471  
... ... @@ -2489,9 +2489,9 @@
2489 2489  
2490 2490  == **Printer** ==
2491 2491  
2492 -The printing object is primarily suitable for printing out or screenshots saving when connected to micro printer.
2471 +The printing object is primarily suitable for print out or screenshots saving when connected to micro printer.
2493 2493  
2494 -Printer has two types: serial printer and USB printer. Printf (printext function) should be called when it's used to print fixed message in a script.
2473 +Printer has two types: **serial printer and USB printer**. Printf (printext function) should be called when it's used to print fixed message in a script.
2495 2495  
2496 2496  **Printer protocol**
2497 2497  
... ... @@ -2511,18 +2511,18 @@
2511 2511  **(1) Display settings**
2512 2512  
2513 2513  1. **Direction: **Four direction choices in printing: 0, 90, 180, and 270.
2514 -1. **Zoom in: **Check "Zoom in" to zoom printing content in proportion to paper size.
2493 +1. **Zoom in: **Check "Zoom in" to zoom printing content in proportion with paper size.
2515 2515  
2516 2516  **(2) Trigger mode**
2517 2517  
2518 -1. **Trigger address: **When trigger address turns ON. The printer starts to respond operationally.
2497 +1. **Trigger address: **When trigger address turns ON.Printer starts to respond operation.
2519 2519  1. **Printer\ Save:** It sets operation for this object, printer object could support sending printing command to printer device, and including screenshot.
2520 2520  
2521 2521  **(3) Save path**
2522 2522  
2523 -Valid when the save mode is selected, screenshot the content in printing object area, and save it in specified storage and folder, when trigger address turns ON.
2502 +Valid when the save mode is selected, screenshot the content in printing object area and the save it in specified storage and folder, when trigger address turns ON.
2524 2524  
2525 -Folder: It's available to select an SD card or USB disk. Set the file name to "Abc" in folder, and it would automatically generate a folder "Abc" when you save picture the first time, and all the pictures will save in this folder. The folder name consists of mixed uppercase and lowercase letters and numbers within 32 characters.
2504 +Folder: It's available to select SD card or USB disk. Set the file name to "Abc" in folder, and it would automatically generate a folder "Abc" when you save picture first time, and all the pictures will save in this folder. The folder name consists of mixed uppercase and lowercase letters and numbers within 32 characters.
2526 2526  
2527 2527  **Related issues**
2528 2528  
... ... @@ -2615,14 +2615,16 @@
2615 2615  
2616 2616  == **Text** ==
2617 2617  
2618 -It adds text to HMI screen, and an object can be displayed in 8 languages (set in "All Languages") with a special address setting.
2597 +It adds text to HMI screen, and a object can be displayed in 8 languages (set in "All Languages") with a special address setting.
2619 2619  
2599 +**Description**
2600 +
2620 2620  (% style="text-align:center" %)
2621 2621  [[image:6.Objects_html_3cae6153cc6e4750.gif||class="img-thumbnail"]]
2622 2622  
2623 2623  **(1) Current state**
2624 2624  
2625 -It is used to switch the object states, but [Text] object only has one state, so this function is invalid.
2606 +It used to switch the object states, but [Text] object only has one state, so this function is invalid.
2626 2626  
2627 2627  **(2) All language**
2628 2628  
... ... @@ -2641,7 +2641,7 @@
2641 2641  
2642 2642  **(5) Text color**
2643 2643  
2644 -It sets color of text in object.
2625 +It sets color for text in object.
2645 2645  
2646 2646  **(6) Text background**
2647 2647  
... ... @@ -2649,8 +2649,10 @@
2649 2649  
2650 2650  == **Table** ==
2651 2651  
2652 -It is displayed in a table format on the HMI screen to meet the display needs of user.
2633 +It is displayed in a table format in the HMI screen to meet the display needs of user.
2653 2653  
2635 +**Description**
2636 +
2654 2654  (% style="text-align:center" %)
2655 2655  [[image:6.Objects_html_2aad7ef679949d71.gif||class="img-thumbnail"]]
2656 2656  
... ... @@ -2663,7 +2663,7 @@
2663 2663  1. **Border:** It sets table line color, including table line and frame line.
2664 2664  1. **Transparence: **It sets the transparency of the object background.
2665 2665  1. **Fill style: **There are two options for it, one is display background, and the other is no background.
2666 -1. **Background:** Valid when selecting display background in "Fill style".
2649 +1. **Background:** Valid when select display background in "Fill style".
2667 2667  
2668 2668  **(2) View**
2669 2669  
... ... @@ -2673,6 +2673,8 @@
2673 2673  
2674 2674  It is displayed in line format in the HMI screen to meet the display needs of user.
2675 2675  
2659 +**Description**
2660 +
2676 2676  (% style="text-align:center" %)
2677 2677  [[image:6.Objects_html_795af47bf0ad8529.gif||class="img-thumbnail"]]
2678 2678  
... ... @@ -2690,7 +2690,7 @@
2690 2690  
2691 2691  **(3) Coordinate control**
2692 2692  
2693 -Dynamically set the position coordinate between two points in line. Set four addresses respectively corresponding to the starting point and end point coordinate. If the numerical value of coordinate is over interface, the object will not be displayed.
2678 +Dynamically set the position coordinate between two points in line. Set four addressesrespectively corresponding to the starting point and end point coordinate. If the numerical value of coordinate is over interface, the object will not be displayed.
2694 2694  
2695 2695  **(4) Color control**
2696 2696  
... ... @@ -2702,10 +2702,12 @@
2702 2702  
2703 2703  == **Polygon** ==
2704 2704  
2705 -It is displayed in polygon format on the HMI screen to meet the display needs of user.
2690 +It is displayed in polygon format in the HMI screen to meet the display needs of user.
2706 2706  
2707 2707  Right click to close polygon and then complete the creation procedure. Select the polygon, then click its point position to change its vertex coordinate after it is created.
2708 2708  
2694 +**Description**
2695 +
2709 2709  (% style="text-align:center" %)
2710 2710  [[image:6.Objects_html_9f46a2daf3b48e68.gif||class="img-thumbnail"]]
2711 2711  
... ... @@ -2714,7 +2714,7 @@
2714 2714  1. **Border color: **It sets border line color.
2715 2715  1. **Border type:** It sets border line type.
2716 2716  1. **Border width: **It sets border line width.
2717 -1. **Transparence: **It sets the transparency of the object's background.
2704 +1. **Transparence: **It sets the transparency of the object background.
2718 2718  1. **Coordinate editing:** It changes coordinate for all points in this object, as below shows.
2719 2719  
2720 2720  (% style="text-align:center" %)
... ... @@ -2738,8 +2738,10 @@
2738 2738  
2739 2739  == **Cycle/ Ellipse** ==
2740 2740  
2741 -It is displayed as cycle on HMI screen to meet the display needs of user.
2728 +It is displayed as cycle in HMI screen to meet the display needs of user.
2742 2742  
2730 +**Description**
2731 +
2743 2743  (% style="text-align:center" %)
2744 2744  [[image:6.Objects_html_1851aaa90af6ee72.gif||class="img-thumbnail"]]
2745 2745  
... ... @@ -2749,8 +2749,8 @@
2749 2749  1. **Frame width: **It sets border line type.
2750 2750  1. **Frame type: **It sets border line width
2751 2751  1. **Pattern: **It sets background type, there are four types.
2752 -1. **Background: **It sets background color of object, invalid when selecting [No fill] in [Pattern]
2753 -1. **Transparence:** It sets the transparency of the object's background.
2741 +1. **Background: **It sets background color of object, invalid when select [No fill] in [Pattern]
2742 +1. **Transparence:** It sets the transparency of the object background.
2754 2754  
2755 2755  **2) Transparence control**
2756 2756  
... ... @@ -2758,7 +2758,7 @@
2758 2758  
2759 2759  **3) Cycle**
2760 2760  
2761 -Check if it is for circle; uncheck it for ellipse.
2750 +Check if for circle; uncheck it for ellipse.
2762 2762  
2763 2763  **4) Color control**
2764 2764  
... ... @@ -2784,6 +2784,7 @@
2784 2784  
2785 2785  **2) Display settings**
2786 2786  
2776 +
2787 2787  (% style="text-align:center" %)
2788 2788  [[image:6.Objects_html_4729b28f315a5a9b.gif||class="img-thumbnail"]]
2789 2789  
... ... @@ -2792,7 +2792,7 @@
2792 2792  1. **Line width: **It sets border line type.
2793 2793  1. **Fill style: **It sets background type, there are four types.
2794 2794  1. **Transparence:** It sets the transparency of the object background.
2795 -1. **Background: **It sets background color of object, invalid when selecting [No fill] in [Pattern].
2785 +1. **Background: **It sets background color of object, invalid when select [No fill] in [Pattern].
2796 2796  
2797 2797  **(3) Only show arc**
2798 2798  
... ... @@ -2818,6 +2818,8 @@
2818 2818  
2819 2819  The line segments are linked end-to-end to form a broken line, whose vertex coordinate can be modified by drafting, just like polygon.
2820 2820  
2811 +**Description**
2812 +
2821 2821  (% style="text-align:center" %)
2822 2822  [[image:6.Objects_html_c3b0de1d4c2fe745.gif||class="img-thumbnail"]]
2823 2823  
... ... @@ -2840,7 +2840,7 @@
2840 2840  
2841 2841  In basic display settings, the line width can't be changed, but user can change width by address.
2842 2842  
2843 -Read the numerical value of address to control the width of line. Display range of numerical value:1-10.
2835 +Read the numerical value of address to control the width of line.Display range of numerical value:1-10.
2844 2844  
2845 2845  **(4) View**
2846 2846  
... ... @@ -2850,6 +2850,8 @@
2850 2850  
2851 2851  The linear scale is a linear scale that draws the specified area with a bisector. The specific scale of the scale can be marked with static text.
2852 2852  
2845 +**Description**
2846 +
2853 2853  (% style="text-align:center" %)
2854 2854  [[image:6.Objects_html_b604bd83c8b8b6d1.gif||class="img-thumbnail"]]
2855 2855  
... ... @@ -2857,12 +2857,12 @@
2857 2857  
2858 2858  1. **Line color:** It sets all line in object (including main and sub scale).
2859 2859  1. **Display direction: **It provides four modes for display.
2860 -1. **Main scale: **It sets the cell of the main scale.
2854 +1. **Main scale:**It sets the cell of the main scale.
2861 2861  1. **Sub scale:** It sets the cell of sub scale for every main scale.
2862 2862  
2863 2863  **(2) View**
2864 2864  
2865 -It is for preview object.
2859 +It is for preview object;
2866 2866  
2867 2867  == **Arc scale** ==
2868 2868  
... ... @@ -2896,15 +2896,15 @@
2896 2896  
2897 2897  Customized object is provided for users to design the universal interface of object freely to meet customization requirements.
2898 2898  
2893 +**Description**
2894 +
2899 2899  (% style="text-align:center" %)
2900 2900  [[image:6.Objects_html_c8146ad79a9ce732.gif||class="img-thumbnail"]]
2901 2901  
2902 -1. **Function Address:** The numerical value in this address is used as the function code of object to handle the corresponding operation.
2903 -1. **DLL file name: **Select needed dll file. (i.e. dll files provided by users)
2904 -1. **Custom address:** Users can add some function address to cooperate with dll file to complete other operations.
2898 +1. **Function Address:** the numerical value in this address is used as the function code of object to handle the corresponding operation.
2899 +1. **DLL file name: **Select needed dll file (i.e. dll files provided by users)
2900 +1. **Custom address:** users can add some function address to cooperate with dll file to complete other operations
2905 2905  
2906 -(% class="box infomessage" %)
2907 -(((
2908 2908  **✎Note:**
2909 2909  
2910 2910  This is a custom-made object that requires the cooperation of WECON software engineers.
... ... @@ -2911,7 +2911,6 @@
2911 2911  
2912 2912  Required documents: two XXXXXX.dll files and an document.
2913 2913  
2914 -* One dll file is used on PC and should be put under the dll_pc folder in the software installation directory.
2908 +* One dll file is used in PC and should be put under the dll_pc folder in the software installation directory.
2915 2915  * One dll file is used in HMI and should be put under the dll_hmi folder in the software installation directory.
2916 2916  * A document for illustrating the dll files.
2917 -)))
XWiki.XWikiComments[0]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -{{mention reference="XWiki.Roy" style="FULL_NAME" anchor="XWiki-Roy-1tuen8"/}} {{mention reference="XWiki.admin" style="FULL_NAME" anchor="XWiki-admin-v9dwdf"/}} this is test message
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:16:52.686
XWiki.XWikiComments[1]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -{{mention reference="XWiki.admin" style="FULL_NAME" anchor="XWiki-admin-54p1l2"/}} hi
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:20:52.190
XWiki.XWikiComments[2]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -{{mention reference="XWiki.Roy" style="FULL_NAME" anchor="XWiki-Roy-xj75f6"/}} {{mention reference="XWiki.admin" style="FULL_NAME" anchor="XWiki-admin-le3bx2"/}} 这个应该可以了吧
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:23:11.227
XWiki.XWikiComments[3]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -hello
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:28:36.248
XWiki.XWikiComments[4]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -撒反对
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:31:30.668
XWiki.XWikiComments[5]
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.test
Comment
... ... @@ -1,1 +1,0 @@
1 -{{mention reference="XWiki.admin" style="FULL_NAME" anchor="XWiki-admin-z27h71"/}} 最新的测试
Date
... ... @@ -1,1 +1,0 @@
1 -2023-07-27 17:38:03.653