Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
From version 80.1
edited by Jim(Forgotten)
on 2023/08/11 09:26
on 2023/08/11 09:26
Change comment:
There is no comment for this version
To version 86.1
edited by Jim(Forgotten)
on 2023/08/11 09:30
on 2023/08/11 09:30
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1357,7 +1357,10 @@ 1357 1357 ** **History**: It is in data record area configured by data record. Multiple record groups could be configured, and each record group has multiple channels. 1358 1358 ** **Real Time**: It is in Real-time trend chart configured by data record. Multiple record groups could be configured, and each record group has multiple curve numbers. 1359 1359 1360 +(% class="box infomessage" %) 1361 +((( 1360 1360 **✎Note: **There must be one of settings (Data record and real-time trend chart) in configurations, otherwise there will be no data in curve buffer. 1363 +))) 1361 1361 1362 1362 * **Curve No.**: The number of curves is the same as the number of channels in the record group. A maximum of 8 curves could be displayed. After selecting the curve to be displayed, it can set the scale range and scale color of each curve. 1363 1363 * **Enable**: After selecting the corresponding curve number in the status bar and enabling the curve, set different curve styles and colors according to your needs, then select the channel number in the data buffer, and finally set the data range. ... ... @@ -1391,7 +1391,10 @@ 1391 1391 **Function start Address**: Open the sub-screen of the data record query, and the system can automatically allocate the object address of the query screen according to the configured address. When using this component, it will automatically generate buttons for four direction, you can use these four control keys to view the data record display, and automatically create a new sub-screen based on the function start address, the content of the sub-screen is the query setting for span and start time. 1392 1392 When two objects use one function screen at the same time, if the function addresses of the two object are the same, changing the built-in screen will affect the operation of the two display object at the same time. If the function addresses of the two objects are different, the second object with the built-in screen can be displayed normally, and the first object will be displayed abnormally. 1393 1393 1397 +(% class="box infomessage" %) 1398 +((( 1394 1394 **✎Note: ** When copying Data record display, it is recommended to create a new "function screen" to avoid repeated calls that may cause abnormal functions. 1400 +))) 1395 1395 1396 1396 **Start time**: Set the start time and conditions for data viewing. 1397 1397 ... ... @@ -1576,7 +1576,10 @@ 1576 1576 (% style="text-align:center" %) 1577 1577 [[image:6.Objects_html_9612d7685f349400.gif||class="img-thumbnail"]] 1578 1578 1585 +(% class="box infomessage" %) 1586 +((( 1579 1579 ✎**Note:** For the "Text" setting, please refer to "[[text>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fview%2FHelps%2F06.Objects%2F%23HText]]" in "[[Bit Switch>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fedit%2FHelps%2F06.Objects%2FWebHome%3Fsection%3D2]]". 1588 +))) 1580 1580 1581 1581 = **Display** = 1582 1582 ... ... @@ -1639,11 +1639,14 @@ 1639 1639 1. **Variable QR:** It is for setting read address, the content of QR code is from this setting address. 1640 1640 1. **QR String: **It is for set static content for QR code. 1641 1641 1651 +(% class="box infomessage" %) 1652 +((( 1642 1642 **✎Note:** 1643 1643 1644 1644 * HMI machine ID address: HSW10494 ~~ HSW10558. 1645 1645 * So if user want to use QR code to display machine ID on project screen, please check "Variable QR", and set address is HSW10494. 1646 1646 * When scanning the QR code by APP to monitor HMI, the default access password is 888888. 1658 +))) 1647 1647 1648 1648 == **Picture** == 1649 1649 ... ... @@ -1672,10 +1672,13 @@ 1672 1672 1. **Folder: **Set the name of the folder where the picture is located.The folder name can be up to 31 characters. (Note:The picture must be stored in the U disk folder and cannot be stored in the root directory of the U disk.) 1673 1673 1. **File address: **16 consecutive addresses enter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed. 1674 1674 1687 +(% class="box infomessage" %) 1688 +((( 1675 1675 ✎**Note:** 1676 1676 1677 1677 1. The image could be displayed in BMP, JPG, PNG, and JPEG formats. Images with a resolution of 1920 x 1080 or higher are not supported. 1678 1678 1. For the setting of [[animations>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HAnimation]], see the "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 1693 +))) 1679 1679 1680 1680 == **Rotation picture** == 1681 1681 ... ... @@ -1799,9 +1799,12 @@ 1799 1799 1800 1800 Video display is advanced function in PI HMI, this object displays the camera screen in HMI, there are two modes, one is IP camera, and the other is USB camera. But IP camera requires settings in [Project settings], the detailed information, please refer to ~[[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__Camera__>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HCameradisplay]](%%)]. 1801 1801 1817 +(% class="box infomessage" %) 1818 +((( 1802 1802 **✎Note:** 1803 1803 1804 1804 This function requires special HMI model, the detailed information, please contact sales. 1822 +))) 1805 1805 1806 1806 === **IP Camera** === 1807 1807 ... ... @@ -2417,7 +2417,7 @@ 2417 2417 ** ASHU S300 (640*480 2418 2418 ))) 2419 2419 2420 -* \\2438 +* 2421 2421 2422 2422 == **Camera control** == 2423 2423 ... ... @@ -2593,8 +2593,10 @@ 2593 2593 English 2 2594 2594 ))) 2595 2595 2596 -(% class="wikigeneratedid" %) 2614 +(% class="box infomessage" %) 2615 +((( 2597 2597 ✎**Note:** For [[animations>>url:http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HAmination]], see the "[[Bit Switch>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fedit%2FHelps%2F06.Objects%2FWebHome%3Fsection%3D2]]". 2617 +))) 2598 2598 2599 2599 == **Time** == 2600 2600