Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
From version 83.1
edited by Jim(Forgotten)
on 2023/08/11 09:29
on 2023/08/11 09:29
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.Hunter - Content
-
... ... @@ -17,29 +17,29 @@ 17 17 18 18 **Read-write** 19 19 20 -* **Write Address: **Bit switch controls PLC or HMI address. 21 -* **Read Address: **Read and display PLC or HMI bit address state. 20 +* **Write Address: **Bit address operation control for HMI or PLC. 21 +* **Read**: Enable the monitoring the read address or not. 22 +* **Same read-write address**: Enable it if want to the read address and write address is exactly same. 23 +* **Read Address: **Monitoring address. 22 22 23 23 **Mode** 24 24 25 -* **Set OFF:** set off the write address.26 -* **Set ON:** set on the write address.27 -* **Momentary:** set on the write address when switch is pressed, and setoffwhen switch is released.28 -* **Delay:** setoffthe write addressafter a delay.(for example:assign the delay time as 5, write address will be setoffafter releasing5ms.)29 -* **Switch:** switch between0and1 each timethe switch is triggered.27 +* **Set OFF:** Set off the write address. 28 +* **Set ON:** Set on the write address. 29 +* **Momentary:** Set on the write address when switch is pressed, and reset the address when switch is released. 30 +* **Delay: **Interval for keep on the write address. For example: Assign the delay time as 500, write address will be reset after release button in 0.5 second. 31 +* **Switch:** Switch between True(1) and False(0) when switch is triggered. 30 30 31 31 **Display** 32 32 33 33 * **Inverted Display: **Display the state picture and text of the object reversely. 34 -* **Quick Read: **The speed of configuring the object is priority to other objects. 36 +* **Quick Read: **The priority of read and write is higher than any other objects on the same screen. 37 +* **Blink: **Control the state of blink by the bit address of control bit. Blinking while control bit is triggered, the frequency is editable; 38 +** **Blink when ON: **blink when control bit is ON. 39 +** **Blink when OFF: **blink when control bit is OFF. 35 35 36 -** Blink: **Controlthestate of blinkbythebitaddressofcontrolbit. Blinking whilecontrolbit istriggered, thefrequencyiseditable;41 +**Minimum hold time: **Only when the time of press and hold the object is greater than the set value, the object function will be executed. 37 37 38 -* **Blink when ON: **blink when control bit is ON. 39 -* **Blink when OFF: **blink when control bit is OFF. 40 - 41 -**Minimum hold time: **Only when the time of pressing the object is greater than or equal to the set minimum hold time will the function of the object be performed. 42 - 43 43 **Indirect addressing:** 44 44 45 45 * **Read address**: Use the value of the read address to determine the address A after deviation, and use the address A as the read address of the object. ... ... @@ -103,6 +103,19 @@ 103 103 (% style="text-align:center" %) 104 104 [[image:位开关 6.png||class="img-thumbnail"]] 105 105 106 +**No trigger:** No way to trigger 107 + 108 +**Trigger before pressing:** Trigger bit address is set to 1 before pressing 109 + 110 +**Trigger after pressing: **After pressing Enter, trigger bit address is set to 1 before closing the keyboard 111 + 112 +**Trigger and reset before pressing: **Trigger bit address is set to 1 and then set to 0 bedore pressing 113 + 114 +**Trigger and reset after pressing: **After pressing Enter, trigger bit address is set to 1 and then set to 0 before closing the keyboard 115 + 116 +**Trigger before pressing, reset after: **Trigger bit address is set to 1 before pressing; After pressing Enter, trigger bit address is set to 0 before closing the keyboard 117 + 118 + 106 106 **Access denied setting** 107 107 108 108 Users can set enable password for object. There are following operating setting when user permissions are insufficient. But "Pop login screen" and "Hide object" are mutually exclusive. ... ... @@ -1684,10 +1684,13 @@ 1684 1684 1. **Folder: **Set the name of the folder where the picture is located.The folder name can be up to 31 characters. (Note:The picture must be stored in the U disk folder and cannot be stored in the root directory of the U disk.) 1685 1685 1. **File address: **16 consecutive addresses enter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed. 1686 1686 1700 +(% class="box infomessage" %) 1701 +((( 1687 1687 ✎**Note:** 1688 1688 1689 1689 1. The image could be displayed in BMP, JPG, PNG, and JPEG formats. Images with a resolution of 1920 x 1080 or higher are not supported. 1690 1690 1. For the setting of [[animations>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HAnimation]], see the "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 1706 +))) 1691 1691 1692 1692 == **Rotation picture** == 1693 1693 ... ... @@ -1811,9 +1811,12 @@ 1811 1811 1812 1812 Video display is advanced function in PI HMI, this object displays the camera screen in HMI, there are two modes, one is IP camera, and the other is USB camera. But IP camera requires settings in [Project settings], the detailed information, please refer to ~[[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__Camera__>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HCameradisplay]](%%)]. 1813 1813 1830 +(% class="box infomessage" %) 1831 +((( 1814 1814 **✎Note:** 1815 1815 1816 1816 This function requires special HMI model, the detailed information, please contact sales. 1835 +))) 1817 1817 1818 1818 === **IP Camera** === 1819 1819 ... ... @@ -2429,7 +2429,7 @@ 2429 2429 ** ASHU S300 (640*480 2430 2430 ))) 2431 2431 2432 -* \\2451 +* 2433 2433 2434 2434 == **Camera control** == 2435 2435 ... ... @@ -2605,8 +2605,10 @@ 2605 2605 English 2 2606 2606 ))) 2607 2607 2608 -(% class="wikigeneratedid" %) 2627 +(% class="box infomessage" %) 2628 +((( 2609 2609 ✎**Note:** For [[animations>>url:http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HAmination]], see the "[[Bit Switch>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fedit%2FHelps%2F06.Objects%2FWebHome%3Fsection%3D2]]". 2630 +))) 2610 2610 2611 2611 == **Time** == 2612 2612