... ... @@ -1357,10 +1357,7 @@
1357 1357  ** **History**: It is in data record area configured by data record. Multiple record groups could be configured, and each record group has multiple channels.
1358 1358  ** **Real Time**: It is in Real-time trend chart configured by data record. Multiple record groups could be configured, and each record group has multiple curve numbers.
1359 1359  
1360 -(% class="box infomessage" %)
1361 -(((
1362 1362  **✎Note: **There must be one of settings (Data record and real-time trend chart) in configurations, otherwise there will be no data in curve buffer.
1363 -)))
1364 1364  
1365 1365  * **Curve No.**: The number of curves is the same as the number of channels in the record group. A maximum of 8 curves could be displayed. After selecting the curve to be displayed, it can set the scale range and scale color of each curve.
1366 1366  * **Enable**: After selecting the corresponding curve number in the status bar and enabling the curve, set different curve styles and colors according to your needs, then select the channel number in the data buffer, and finally set the data range.
... ... @@ -1394,10 +1394,7 @@
1394 1394  **Function start Address**: Open the sub-screen of the data record query, and the system can automatically allocate the object address of the query screen according to the configured address. When using this component, it will automatically generate buttons for four direction, you can use these four control keys to view the data record display, and automatically create a new sub-screen based on the function start address, the content of the sub-screen is the query setting for span and start time.
1395 1395  When two objects use one function screen at the same time, if the function addresses of the two object are the same, changing the built-in screen will affect the operation of the two display object at the same time. If the function addresses of the two objects are different, the second object with the built-in screen can be displayed normally, and the first object will be displayed abnormally.
1396 1396  
1397 -(% class="box infomessage" %)
1398 -(((
1399 1399  **✎Note: ** When copying Data record display, it is recommended to create a new "function screen" to avoid repeated calls that may cause abnormal functions.
1400 -)))
1401 1401  
1402 1402  **Start time**: Set the start time and conditions for data viewing.
1403 1403  
... ... @@ -1582,10 +1582,7 @@
1582 1582  (% style="text-align:center" %)
1583 1583  [[image:6.Objects_html_9612d7685f349400.gif||class="img-thumbnail"]]
1584 1584  
1585 -(% class="box infomessage" %)
1586 -(((
1587 1587  ✎**Note:** For the "Text" setting, please refer to "[[text>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fview%2FHelps%2F06.Objects%2F%23HText]]" in "[[Bit Switch>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fedit%2FHelps%2F06.Objects%2FWebHome%3Fsection%3D2]]".
1588 -)))
1589 1589  
1590 1590  = **Display** =
1591 1591  
... ... @@ -1648,14 +1648,11 @@
1648 1648  1. **Variable QR:** It is for setting read address, the content of QR code is from this setting address.
1649 1649  1. **QR String: **It is for set static content for QR code.
1650 1650  
1651 -(% class="box infomessage" %)
1652 -(((
1653 1653  **✎Note:**
1654 1654  
1655 1655  * HMI machine ID address: HSW10494 ~~ HSW10558.
1656 1656  * So if user want to use QR code to display machine ID on project screen, please check "Variable QR", and set address is HSW10494.
1657 1657  * When scanning the QR code by APP to monitor HMI, the default access password is 888888.
1658 -)))
1659 1659  
1660 1660  == **Picture** ==
1661 1661  
... ... @@ -1684,13 +1684,10 @@
1684 1684  1. **Folder: **Set the name of the folder where the picture is located.The folder name can be up to 31 characters. (Note:The picture must be stored in the U disk folder and cannot be stored in the root directory of the U disk.)
1685 1685  1. **File address: **16 consecutive addresses enter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed.
1686 1686  
1687 -(% class="box infomessage" %)
1688 -(((
1689 1689  ✎**Note:** 
1690 1690  
1691 1691  1. The image could be displayed in BMP, JPG, PNG, and JPEG formats. Images with a resolution of 1920 x 1080 or higher are not supported.
1692 1692  1. For the setting of [[animations>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HAnimation]], see the "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]".
1693 -)))
1694 1694  
1695 1695  == **Rotation picture** ==