Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
From version 87.1
edited by Mora Zhou
on 2023/10/31 15:50
on 2023/10/31 15:50
Change comment:
There is no comment for this version
To version 79.1
edited by Jim(Forgotten)
on 2023/08/11 09:25
on 2023/08/11 09:25
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.Jim - Content
-
... ... @@ -103,19 +103,6 @@ 103 103 (% style="text-align:center" %) 104 104 [[image:位开关 6.png||class="img-thumbnail"]] 105 105 106 -**No trigger:** No way to trigger 107 - 108 -**Trigger before pressing:** Trigger bit address is set to 1 before pressing 109 - 110 -**Trigger after pressing: **After pressing Enter, trigger bit address is set to 1 before closing the keyboard 111 - 112 -**Trigger and reset before pressing: **Trigger bit address is set to 1 and then set to 0 bedore pressing 113 - 114 -**Trigger and reset after pressing: **After pressing Enter, trigger bit address is set to 1 and then set to 0 before closing the keyboard 115 - 116 -**Trigger before pressing, reset after: **Trigger bit address is set to 1 before pressing; After pressing Enter, trigger bit address is set to 0 before closing the keyboard 117 - 118 - 119 119 **Access denied setting** 120 120 121 121 Users can set enable password for object. There are following operating setting when user permissions are insufficient. But "Pop login screen" and "Hide object" are mutually exclusive. ... ... @@ -1353,10 +1353,7 @@ 1353 1353 1354 1354 The Disc Record displays the data from data source in the form of a disc curve. 1355 1355 1356 -(% class="box infomessage" %) 1357 -((( 1358 1358 **✎Note: **This function are only supported by HMI+, i series, ie series and ig series. 1359 -))) 1360 1360 1361 1361 **Source** 1362 1362 ... ... @@ -1370,10 +1370,7 @@ 1370 1370 ** **History**: It is in data record area configured by data record. Multiple record groups could be configured, and each record group has multiple channels. 1371 1371 ** **Real Time**: It is in Real-time trend chart configured by data record. Multiple record groups could be configured, and each record group has multiple curve numbers. 1372 1372 1373 -(% class="box infomessage" %) 1374 -((( 1375 1375 **✎Note: **There must be one of settings (Data record and real-time trend chart) in configurations, otherwise there will be no data in curve buffer. 1376 -))) 1377 1377 1378 1378 * **Curve No.**: The number of curves is the same as the number of channels in the record group. A maximum of 8 curves could be displayed. After selecting the curve to be displayed, it can set the scale range and scale color of each curve. 1379 1379 * **Enable**: After selecting the corresponding curve number in the status bar and enabling the curve, set different curve styles and colors according to your needs, then select the channel number in the data buffer, and finally set the data range. ... ... @@ -1407,10 +1407,7 @@ 1407 1407 **Function start Address**: Open the sub-screen of the data record query, and the system can automatically allocate the object address of the query screen according to the configured address. When using this component, it will automatically generate buttons for four direction, you can use these four control keys to view the data record display, and automatically create a new sub-screen based on the function start address, the content of the sub-screen is the query setting for span and start time. 1408 1408 When two objects use one function screen at the same time, if the function addresses of the two object are the same, changing the built-in screen will affect the operation of the two display object at the same time. If the function addresses of the two objects are different, the second object with the built-in screen can be displayed normally, and the first object will be displayed abnormally. 1409 1409 1410 -(% class="box infomessage" %) 1411 -((( 1412 1412 **✎Note: ** When copying Data record display, it is recommended to create a new "function screen" to avoid repeated calls that may cause abnormal functions. 1413 -))) 1414 1414 1415 1415 **Start time**: Set the start time and conditions for data viewing. 1416 1416 ... ... @@ -1595,10 +1595,7 @@ 1595 1595 (% style="text-align:center" %) 1596 1596 [[image:6.Objects_html_9612d7685f349400.gif||class="img-thumbnail"]] 1597 1597 1598 -(% class="box infomessage" %) 1599 -((( 1600 1600 ✎**Note:** For the "Text" setting, please refer to "[[text>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fview%2FHelps%2F06.Objects%2F%23HText]]" in "[[Bit Switch>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fedit%2FHelps%2F06.Objects%2FWebHome%3Fsection%3D2]]". 1601 -))) 1602 1602 1603 1603 = **Display** = 1604 1604 ... ... @@ -1661,14 +1661,11 @@ 1661 1661 1. **Variable QR:** It is for setting read address, the content of QR code is from this setting address. 1662 1662 1. **QR String: **It is for set static content for QR code. 1663 1663 1664 -(% class="box infomessage" %) 1665 -((( 1666 1666 **✎Note:** 1667 1667 1668 1668 * HMI machine ID address: HSW10494 ~~ HSW10558. 1669 1669 * So if user want to use QR code to display machine ID on project screen, please check "Variable QR", and set address is HSW10494. 1670 1670 * When scanning the QR code by APP to monitor HMI, the default access password is 888888. 1671 -))) 1672 1672 1673 1673 == **Picture** == 1674 1674 ... ... @@ -1697,13 +1697,10 @@ 1697 1697 1. **Folder: **Set the name of the folder where the picture is located.The folder name can be up to 31 characters. (Note:The picture must be stored in the U disk folder and cannot be stored in the root directory of the U disk.) 1698 1698 1. **File address: **16 consecutive addresses enter a picture name in the address (need to be the full name of the suffix), if the picture exists, the picture content is displayed; otherwise the default picture is displayed. 1699 1699 1700 -(% class="box infomessage" %) 1701 -((( 1702 1702 ✎**Note:** 1703 1703 1704 1704 1. The image could be displayed in BMP, JPG, PNG, and JPEG formats. Images with a resolution of 1920 x 1080 or higher are not supported. 1705 1705 1. For the setting of [[animations>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HAnimation]], see the "[[Bit Switch>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HBitswitch]]". 1706 -))) 1707 1707 1708 1708 == **Rotation picture** == 1709 1709 ... ... @@ -1827,12 +1827,9 @@ 1827 1827 1828 1828 Video display is advanced function in PI HMI, this object displays the camera screen in HMI, there are two modes, one is IP camera, and the other is USB camera. But IP camera requires settings in [Project settings], the detailed information, please refer to ~[[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__Camera__>>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HCameradisplay]](%%)]. 1829 1829 1830 -(% class="box infomessage" %) 1831 -((( 1832 1832 **✎Note:** 1833 1833 1834 1834 This function requires special HMI model, the detailed information, please contact sales. 1835 -))) 1836 1836 1837 1837 === **IP Camera** === 1838 1838 ... ... @@ -2448,7 +2448,7 @@ 2448 2448 ** ASHU S300 (640*480 2449 2449 ))) 2450 2450 2451 -* 2417 +* \\ 2452 2452 2453 2453 == **Camera control** == 2454 2454 ... ... @@ -2624,10 +2624,8 @@ 2624 2624 English 2 2625 2625 ))) 2626 2626 2627 -(% class="box infomessage" %) 2628 -((( 2593 +(% class="wikigeneratedid" %) 2629 2629 ✎**Note:** For [[animations>>url:http://docs.we-con.com.cn/wiki/pistudio/view/Helps/06.Objects/#HAmination]], see the "[[Bit Switch>>url:http://docs.we-con.com.cn/wiki/pistudio/get/Helps/06.Objects/?sheet=CKEditor.ResourceDispatcher&outputSyntax=plain&language=en&type=doc&reference=http%3A%2F%2Fdocs.we-con.com.cn%2Fwiki%2Fpistudio%2Fedit%2FHelps%2F06.Objects%2FWebHome%3Fsection%3D2]]". 2630 -))) 2631 2631 2632 2632 == **Time** == 2633 2633