Changes for page 05 Objects
Last modified by Jett on 2025/07/04 09:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -153,7 +153,7 @@ 153 153 * Y-axis movement. 154 154 * XY-axis movement. 155 155 156 -**For ex **a**mple**156 +**For example** 157 157 158 158 If the starting address of the movement is HDW10 and the movement type is [XY axis movement], HDW10 controls the X-axis movement, and HDW11 controls the Y-axis movement. 159 159 ... ... @@ -475,7 +475,7 @@ 475 475 476 476 == Slide switch == 477 477 478 - Slide switch is a special switch object.By changing the position of the slider, the corresponding address value would be changed. At the same time, the slider position will change according to the address value.478 +By changing the position of the slider, the corresponding address value would be changed. At the same time, the slider position will change according to the address value. 479 479 480 480 (% style="text-align:center" %) 481 481 [[image:6.Objects_html_cc27b49cc3421a77.gif||class="img-thumbnail"]] ... ... @@ -548,7 +548,7 @@ 548 548 549 549 == Numeric Input/Display == 550 550 551 -"Numeric Input/Display" displays the device's data or writes data to the device in a specified numeric format , and the data could be scaled.551 +"Numeric Input/Display" displays the device's data or writes data to the device in a specified numeric format. 552 552 553 553 (% style="text-align:center" %) 554 554 [[image:6-1NumericInput.png||class="img-thumbnail"]] ... ... @@ -566,7 +566,7 @@ 566 566 **✎Note: **Check it to use the comment information on the keyboard. When the user clicks on the part, the comment information will be written into the HUW1402 for display. The maximum length allowed for the comment is 63 characters; 567 567 ))) 568 568 569 -* **Continuous Input: ** Use the samekeyboardtoinputtheobjectsfromthe same Group NOaccordingtotheorderof NO, and automaticallyclosethe keyboard after thelastNO(object) is input;569 +* **Continuous Input: **Numeric input objects with the same Group NO can be entered continuously using the same keyboard according to the NO order; 570 570 * **NO: **the number of numeric input object; 571 571 * **Group NO: **the group number of numeric input object; 572 572 ... ... @@ -598,7 +598,7 @@ 598 598 599 599 **Keypad position** 600 600 601 - It is usedforsettingkeypadposition wheninput data.601 +The pop-up position of keypad screen. 602 602 603 603 **Label** 604 604 ... ... @@ -614,7 +614,7 @@ 614 614 615 615 == Character Input/Display == 616 616 617 -" Numeric Input/Display" displays the device's character or writes character to the device.617 +"Character Input/Display" displays the device's character or writes character to the device. 618 618 619 619 **Description** 620 620 ... ... @@ -626,15 +626,10 @@ 626 626 * **Read Address:** The data from designated address will be displayed. 627 627 * **Input: **Enable input function and "Write Address" configuration. 628 628 * **Same read-write address:** Configure "Write Address" is the same as "Read Address". 629 -* **Read DWord: **Read address is2wordsformat629 +* **Read DWord: **Read the address data at double byte format. 630 630 * **Write address: **Write data to designated address. The address could be different "Read Address". 631 -* **Keypad:** it is standard numeric keypad, allow to input decimal and floating; 632 - 633 -(% class="box infomessage" %) 634 -((( 635 -**✎Note:** ** **Check it to use the comment information on the keyboard. When the user clicks on the part, the comment information will be written into the HUW1402 for display. The maximum length allowed for the comment is 63 characters; 636 -))) 637 - 631 +* **Keypad:** Built-in character keyboard input(Screen No.1001) could allow input a~~z, A~~Z, 0~~9. 632 +* **Note**: After the keypad is opened, the content of note will be input into special register HUW1402. The maximum length allowed for the note is 63 characters. 638 638 * **Continuous Input: **Use the same keyboard to input the objects from the same Group NO according to the order of NO, and automatically close the keyboard after the last NO (object) is input. 639 639 * **NO: **the number of numeric input object. 640 640 * **Group NO: **the group number of numeric input object. ... ... @@ -651,9 +651,9 @@ 651 651 * **Center:** data display on the center of object. 652 652 * **Align left: **data display on the left. 653 653 * **Align right: **data display on the right. 654 -* **Exchange high-low byte: ** ExchangeHigh-lowbyte:Checkit to exchangeanddisplaythecontentsofthehigh andlow bytes.numberof contents is not a multiple of 2, therounding processwillbeperformed.649 +* **Exchange high-low byte: **Swap the contents of high byte and low byte then display. High byte data into low byte position, low byte data into high byte position. If the length of characters is not a multiple of 2, it will exchange after rounded. 655 655 * **Length: **The length of characters, the maximum length is 256. 656 -* **Exchange high-low word: ** Check it to exchange and displaythe contents of high and low word. Only validifthenumberofoperatingcharactersof the partis a multiple of 4.651 +* **Exchange high-low word: **Swap the contents of high word and low word then display. Only valid when the length of characters is a multiple of 4. 657 657 658 658 **Keypad position** 659 659 ... ... @@ -1415,7 +1415,7 @@ 1415 1415 1416 1416 == **Pointer meter** == 1417 1417 1418 -Th emeterresponds to changeinthevalue of theindicatedword address by means of a dial and a pointer.The meter looks very similarto the actual meter.1413 +This object shows the numerical change of the word address by meter format. 1419 1419 1420 1420 (% style="text-align:center" %) 1421 1421 [[image:image-20220805161001-1.jpeg]] ... ... @@ -1493,7 +1493,7 @@ 1493 1493 1494 1494 **(3) Alarm settings** 1495 1495 1496 - It provides alarmfunctioninmeter,userscouldsetalarmrange,userscouldsetthe4 ranges. And each rangecorrespondsto a different alarmcolor.1491 +Alarm setting can be configured to display different colors, with each color corresponding to a different range. There are a maximum of four alert ranges. 1497 1497 1498 1498 **(4) Show scale** 1499 1499